8 resultados para LD pump

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents the findings of applying a Discrete Demand Side Control (DDSC) approach to the space heating of two case study buildings. High and low tolerance scenarios are implemented on the space heating controller to assess the impact of DDSC upon buildings with different thermal capacitances, light-weight and heavy-weight construction. Space heating is provided by an electric heat pump powered from a wind turbine, with a back-up electrical network connection in the event of insufficient wind being available when a demand occurs. Findings highlight that thermal comfort is maintained within an acceptable range while the DDSC controller maintains the demand/supply balance. Whilst it is noted that energy demand increases slightly, as this is mostly supplied from the wind turbine, this is of little significance and hence a reduction in operating costs and carbon emissions is still attained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is currently an increased interest of Government and Industry in the UK, as well as at the European Community level and International Agencies (i.e. Department of Energy, American International Energy Agency), to improve the performance and uptake of Ground Coupled Heat Pumps (GCHP), in order to meet the 2020 renewable energy target. A sound knowledge base is required to help inform the Government Agencies and advisory bodies; detailed site studies providing reliable data for model verification have an important role to play in this. In this study we summarise the effect of heat extraction by a horizontal ground heat exchanger (installed at 1 m depth) on the soil physical environment (between 0 and 1 m depth) for a site in the south of the UK. Our results show that the slinky influences the surrounding soil by significantly decreasing soil temperatures. Furthermore, soil moisture contents were lower for the GCHP soil profile, most likely due to temperature-gradient related soil moisture migration effects and a decreased hydraulic conductivity, the latter as a result of increased viscosity (caused by the lower temperatures for the GCHP soil profile). The effects also caused considerable differences in soil thermal properties. This is the first detailed mechanistic study conducted in the UK with the aim to understand the interactions between the soil, horizontal heat exchangers and the aboveground environment. An increased understanding of these interactions will help to achieve an optimum and sustainable use of the soil heat resources in the future. The results of this study will help to calibrate and verify a simulation model that will provide UK-wide recommendations to improve future GCHP uptake and performance, while safeguarding the soil physical resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Common approaches to the simulation of borehole heat exchangers (BHEs) assume heat transfer in circulating fluid and grout to be in a quasi-steady state and ignore fluctuations in fluid temperature due to transport of the fluid around the loop. However, in domestic ground source heat pump (GSHP) systems, the heat pump and circulating pumps switch on and off during a given hour; therefore, the effect of the thermal mass of the circulating fluid and the dynamics of fluid transport through the loop has important implications for system design. This may also be important in commercial systems that are used intermittently. This article presents transient simulation of a domestic GSHP system with a single BHE using a dynamic three-dimensional (3D) numerical BHE model. The results show that delayed response associated with the transit of fluid along the pipe loop is of some significance in moderating swings in temperature during heat pump operation. In addition, when 3D effects are considered, a lower heat transfer rate is predicted during steady operations. These effects could be important when considering heat exchanger design and system control. The results will be used to develop refined two-dimensional models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review investigates the performance of photovoltaic and solar-assisted ground-source heat pumps in which solar heat is transferred to the ground to improve the coefficient of performance. A number of studies indicate that, for systems with adequately sized ground heat exchangers, the effect on system efficiency is small: about 1% improvement if the heat source is photovoltaic, a 1–2% decline if the source is solar thermal. With possible exceptions for systems in which the ground heat exchanger is undersized, or natural recharge from ground water is insufficient, solar thermal energy is better used for domestic hot water than to recharge ground heat. This appears particularly true outside the heating season, as although much of the heat extracted from the ground can be replaced, it seems to have little effect on the coefficient of performance. Any savings in electrical consumption that do result from an improved coefficient can easily be outweighed by an inefficient control system for the circulation pumps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: In Escherichia coli, increased expression of efflux pumps and/or decreased expression of porins can confer multiple antibiotic resistance (MAR), causing resistance to at least three unrelated classes of antibiotics, detergents and dyes. It was hypothesized that in Campylobacter jejuni, the efflux systems CmeABC, CmeDEF and the major outer membrane porin protein, MOMP (encoded by porA) could confer MAR. Methods: The expression of cmeB, cmeF and porA in 32 MAR C. jejuni isolated from humans or poultry was determined by comparative (C)-reverse transcriptase (RT)-PCR and denaturing DHPLC. A further 13 ethidium bromide-resistant isolates and three control strains were also investigated. Accumulation of ciprofloxacin carbonyl cyanide-m-chlorophenyl hydrazone (CCCP) was also determined for all strains. Results: Although resistance to ethidium bromide has been associated with MAR, expression of all three genes was similar in the ethidium bromide-resistant isolates. These data indicate that CmeB, CmeF and MOMP play no role in resistance to this agent in C. jejuni. Six MAR isolates over-expressed cmeB, 3/32 over-expressed cmeB and cmeF. No isolates over-expressed cmeF alone. Expression of porA was similar in all isolates. All nine isolates that over-expressed cmeB contained a mutation in cmeR, substituting glycine 86 with alanine. All cmeB over-expressing isolates also accumulated low concentrations of ciprofloxacin, which were restored to wild-type levels in the presence of CCCP. Conclusions: These data indicate that over-expression of cmeB is associated with MAR in isolates of C. jejuni. However, as cmeB was over-expressed by only one-third (9/32) of MAR isolates, these data also indicate other mechanisms of MAR in C. jejuni.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine the efficacy of enrofloxacin (Baytril) in chickens in eradicating three different resistance phenotypes of Salmonella enterica and to examine the resistance mechanisms of resulting mutants. Methods: In two separate replicate experiments (I and 11), three strains of Salmonella enterica serovar Typhimurium DT104 [strain A, fully antibiotic-sensitive strain; strain B, isogenic multiple antibiotic-resistant (MAR) derivative of A; strain C, veterinary penta-resistant phenotype strain containing GyrA Phe-83], were inoculated into day-old chicks at similar to 10(3) Cfu/bird. At day 10, groups of chicks (n =10) were given either enrofloxacin at 50 ppm in their drinking water for 5 days or water alone (control). Caecal contents were monitored for presence of Salmonella and colonies were replica plated to media containing antibiotics or overlaid with cyclohexane to determine the proportion of isolates with reduced susceptibility. The MICs of antibiotics and cyclohexane tolerance were determined for selected isolates from the chicks. Mutations in topoisomerase genes were examined by DHPLC and expression of marA, soxS, acrB, acrD and acrF by RT-PCR. Results: In experiment 1, but not 11, enrofloxacin significantly reduced the numbers of strain A compared with the untreated control group. In experiment 11, but not 1, enrofloxacin significantly reduced the numbers of strain B. Shedding of strain C was unaffected by enrofloxacin treatment. Birds infected with strains A and B gave rise to isolates with decreased fluoroquinolone susceptibility. Isolates derived from strain A or B requiring > 128 mg/L nalidixic acid for inhibition contained GyrA Asn-82 or Phe-83. Isolates inhibited by 16 mg/L nalidixic acid were also less susceptible to antibiotics of other chemical classes and became cyclohexane-tolerant (e.g. MAR). Conclusions: These studies demonstrate that recommended enrofloxacin treatment of chicks rapidly selects for strains with reduced fluoroquinolone susceptibility from fully sensitive and MAR strains. It can also select for MAR isolates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ground source heat pump assisted by an array of photovoltaic (PV)-thermal modules was studied in this work. Extracting heat from an array of PV modules should improve the performance of both the PV cells and the heat pump. A series of computer simulations compare the performance of a ground source heat pump with a short ground circuit, used to provide space heating and domestic hot water at a house in southern England. The results indicate that extracting heat from an array of PV-thermal modules would improve the performance of a ground source heat pump with an undersized ground loop. Nevertheless, open air thermal collectors could be more effective, especially during winter. In one model more electricity was saved in ohmic heating than was generated by cooling the PV cells. Cooling the PV modules was found to increase their electrical output up to 4%, but much of the extra electricity was consumed by the cooling pumps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent urban air temperature increase is attributable to the climate change and heat island effects due to urbanization. This combined effects of urbanization and global warming can penetrate into the underground and elevate the subsurface temperature. In the present study, over-100 years measurements of subsurface temperature at a remote rural site were analysed, and an increasing rate of 0.17⁰C per decade at soil depth of 30cm due to climate change was identified in the UK, but the subsurface warming in an urban site showed a much higher rate of 0.85⁰C per decade at a 30cm depth and 1.18⁰C per decade at 100cm. The subsurface urban heat island (SUHI) intensity obtained at the paired urban-rural stations in London showed an unique 'U-shape', i.e. lowest in summer and highest during winter. The maximum SUHII is 3.5⁰C at 6:00 AM in December, and the minimum UHII is 0.2⁰C at 18:00PM in July. Finally, the effects of SUHI on the energy efficiency of the horizontal ground source heat pump (GSHP) were determined. Provided the same heat pump used, the installation at an urban site will maintain an overall higher COP compared with that at a rural site in all seasons, but the highest COP improvement can be achieved in winter.