129 resultados para Intangible assets. Dynamic capabilities. Performance of tourist destinations

em CentAUR: Central Archive University of Reading - UK


Relevância:

100.00% 100.00%

Publicador:

Resumo:

How do organizations previously dominated by the state develop dynamic capabilities that would support their growth in a competitive market economy? We develop a theoretical framework of organizational transformation that explains the processes by which organizations learn and develop dynamic capabilities in transition economies. Specifically, the framework theorizes about the importance of, and inter-relationships between, leadership, organizational learning, dynamic capabilities, and performance over three stages of transformation. Propositions derived from this framework explain the pre-conditions enabling organizational learning, the linkages between types of learning and functions of dynamic capabilities, and the feedback from dynamic capabilities to organizational learning that allows firms in transition economies to regain their footing and build long-term competitive advantage. We focus on transition contexts, where these processes have been magnified and thus offer new insights into strategizing in radically altered environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dense deployments of wireless local area networks (WLANs) are fast becoming a permanent feature of all developed cities around the world. While this increases capacity and coverage, the problem of increased interference, which is exacerbated by the limited number of channels available, can severely degrade the performance of WLANs if an effective channel assignment scheme is not employed. In an earlier work, an asynchronous, distributed and dynamic channel assignment scheme has been proposed that (1) is simple to implement, (2) does not require any knowledge of the throughput function, and (3) allows asynchronous channel switching by each access point (AP). In this paper, we present extensive performance evaluation of this scheme when it is deployed in the more practical non-uniform and dynamic topology scenarios. Specifically, we investigate its effectiveness (1) when APs are deployed in a nonuniform fashion resulting in some APs suffering from higher levels of interference than others and (2) when APs are effectively switched `on/off' due to the availability/lack of traffic at different times, which creates a dynamically changing network topology. Simulation results based on actual WLAN topologies show that robust performance gains over other channel assignment schemes can still be achieved even in these realistic scenarios.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we draw on the theory of dynamic capabilities to examine development of the only surviving family-owned Liverpool shipping company. The Bibby Line was founded in 1807 to take advantage of the growing sea-trade based in Liverpool. The company remained in shipping until the mid-1960s, when a series of external crises led the owner, Derek Bibby, to begin a process of diversification. In the last 50 years, the Bibby Line has grown into a £1bn business with interests in retail, distribution and financial services as well as a continuing commitment to shipping. Our intention is to demonstrate how multigenerational ownership contributes to the creation of dynamic capabilities in family firms. The distinctive nature of Bibby as a long-standing family business is related to unique assets such as patient capital, flexible governance structures as well as the ability to mobilise social and human capital.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

What are the microfoundations of dynamic capabilities that sustain competitive advantage in a highly volatile environment, such as a transition economy? We explore the detailed nature of these dynamic capabilities along with their antecedents by tracing the sequence of their development based on a longitudinal case study of an organization subject to an external context of radical transition — the Russian oil company, Yukos. Our rich qualitative data indicate two distinct types of dynamic capabilities that are pivotal for organizational transformation. Adaptation dynamic capabilities relate to routines of resource exploitation and deployment, which are supported by acquisition, internalization and dissemination of extant knowledge, as well as resource reconfiguration, divestment and integration. Innovation dynamic capabilities relate to the creation of completely new capabilities via exploration and path-creation processes, which are supported by search, experimentation and risk taking, as well as project selection, funding and implementation. Second, we find that sequencing the two types of dynamic capabilities, helped the organization both to secure short-term competitive advantage, and to create the basis for long-term competitive advantage. These dynamic capability constructs advance theoretical understanding of what dynamic capabilities are, whilst their sequencing explains how firms create, leverage and enhance them over time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Strategy is a contested concept. The generic literature is characterized by a diverse range of competing theories and alternative perspectives. Traditional models of the competitive strategy of construction firms have tended to focus on exogenous factors. In contrast, the resource-based view of strategic management emphasizes the importance of endogenous factors. The more recently espoused concept of dynamic capabilities extends consideration beyond static resources to focus on the ability of firms to reconfigure their operating routines to enable responses to changing environments. The relevance of the dynamics capabilities framework to the construction sector is investigated through an exploratory case study of a regional contractor. The focus on how firms continuously adapt to changing environments provides new insights into competitive strategy in the construction sector. Strong support is found for the importance of path dependency in shaping strategic choice. The case study further suggests that strategy is a collective endeavour enacted by a loosely defined group of individual actors. Dynamic capabilities are characterized by an empirical elusiveness and as such are best construed as situated practices embedded within a social and physical context.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with the energy consumption and the evaluation of the performance of air supply systems for a ventilated room involving high- and low-level supplies. The energy performance assessment is based on the airflow rate, which is related to the fan power consumption by achieving the same environmental quality performance for each case. Four different ventilation systems are considered: wall displacement ventilation, confluent jets ventilation, impinging jet ventilation and a high level mixing ventilation system. The ventilation performance of these systems will be examined by means of achieving the same Air Distribution Index (ADI) for different cases. The widely used high-level supplies require much more fan power than those for low-level supplies for achieving the same value of ADI. In addition, the supply velocity, hence the supply dynamic pressure, for a high-level supply is much larger than for low-level supplies. This further increases the power consumption for high-level supply systems. The paper considers these factors and attempts to provide some guidelines on the difference in the energy consumption associated with high and low level air supply systems. This will be useful information for designers and to the authors' knowledge there is a lack of information available in the literature on this area of room air distribution. The energy performance of the above-mentioned ventilation systems has been evaluated on the basis of the fan power consumed which is related to the airflow rate required to provide equivalent indoor environment. The Air Distribution Index (ADI) is used to evaluate the indoor environment produced in the room by the ventilation strategy being used. The results reveal that mixing ventilation requires the highest fan power and the confluent jets ventilation needs the lowest fan power in order to achieve nearly the same value of ADI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The General Packet Radio Service (GPRS) has been developed for the mobile radio environment to allow the migration from the traditional circuit switched connection to a more efficient packet based communication link particularly for data transfer. GPRS requires the addition of not only the GPRS software protocol stack, but also more baseband functionality for the mobile as new coding schemes have be en defined, uplink status flag detection, multislot operation and dynamic coding scheme detect. This paper concentrates on evaluating the performance of the GPRS coding scheme detection methods in the presence of a multipath fading channel with a single co-channel interferer as a function of various soft-bit data widths. It has been found that compressing the soft-bit data widths from the output of the equalizer to save memory can influence the likelihood decision of the coding scheme detect function and hence contribute to the overall performance loss of the system. Coding scheme detection errors can therefore force the channel decoder to either select the incorrect decoding scheme or have no clear decision which coding scheme to use resulting in the decoded radio block failing the block check sequence and contribute to the block error rate. For correct performance simulation, the performance of the full coding scheme detection must be taken into account.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a simplified dynamic thermal model which simulates the energy and overheating performance of windows. To calculate artificial energy use within a room, the model employs the average illuminance method, which takes into account the daylight energy impacting upon the room by the use of hourly climate data. This tool describes the main thermal performance ( heating, cooling and overheating risk) resulting proposed a design of window. The inputs are fewer and simpler than that are required by complicated simulation programmes. The method is suited for the use of architects and engineers at the strategic phase of design, when little is available.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper presents an overview of dynamic systems with inherent delays in both feedforward and feedback paths and how the performance of such systems can be affected by such delays. The authors concentrate on visually guided systems, where the behaviour of the system is largely dependent on the results of the vision sensors, with particular reference to active robot heads (real-time gaze control). We show how the performance of such systems can deteriorate substantially with the presence of unknown and/or variable delays. Considered choice of system architecture, however, allows the performance of active vision systems to be optimised with respect to the delays present in the system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The evaluation of investment fund performance has been one of the main developments of modern portfolio theory. Most studies employ the technique developed by Jensen (1968) that compares a particular fund's returns to a benchmark portfolio of equal risk. However, the standard measures of fund manager performance are known to suffer from a number of problems in practice. In particular previous studies implicitly assume that the risk level of the portfolio is stationary through the evaluation period. That is unconditional measures of performance do not account for the fact that risk and expected returns may vary with the state of the economy. Therefore many of the problems encountered in previous performance studies reflect the inability of traditional measures to handle the dynamic behaviour of returns. As a consequence Ferson and Schadt (1996) suggest an approach to performance evaluation called conditional performance evaluation which is designed to address this problem. This paper utilises such a conditional measure of performance on a sample of 27 UK property funds, over the period 1987-1998. The results of which suggest that once the time varying nature of the funds beta is corrected for, by the addition of the market indicators, the average fund performance show an improvement over that of the traditional methods of analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Heating, ventilation, air conditioning and refrigeration (HVAC&R) systems account for more than 60% of the energy consumption of buildings in the UK. However, the effect of the variety of HVAC&R systems on building energy performance has not yet been taken into account within the existing building energy benchmarks. In addition, the existing building energy benchmarks are not able to assist decision-makers with HVAC&R system selection. This study attempts to overcome these two deficiencies through the performance characterisation of 36 HVAC&R systems based on the simultaneous dynamic simulation of a building and a variety of HVAC&R systems using TRNSYS software. To characterise the performance of HVAC&R systems, four criteria are considered; energy consumption, CO2 emissions, thermal comfort and indoor air quality. The results of the simulations show that, all the studied systems are able to provide an acceptable level of indoor air quality and thermal comfort. However, the energy consumption and amount of CO2 emissions vary. One of the significant outcomes of this study reveals that combined heating, cooling and power systems (CCHP) have the highest energy consumption with the lowest energy related CO2 emissions among the studied HVAC&R systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermochromic windows are able to modulate their transmittance in both the visible and the near-infrared field as a function of their temperature. As a consequence, they allow to control the solar gains in summer, thus reducing the energy needs for space cooling. However, they may also yield a reduction in the daylight availability, which results in the energy consumption for indoor artificial lighting being increased. This paper investigates, by means of dynamic simulations, the application of thermochromic windows to an existing office building in terms of energy savings on an annual basis, while also focusing on the effects in terms of daylighting and thermal comfort. In particular, due attention is paid to daylight availability, described through illuminance maps and by the calculation of the daylight factor, which in several countries is subject thresholds. The study considers both a commercially available thermochromic pane and a series of theoretical thermochromic glazing. The expected performance is compared to static clear and reflective insulating glass units. The simulations are repeated in different climatic conditions, showing that the overall energy savings compared to clear glazing can range from around 5% for cold climates to around 20% in warm climates, while not compromising daylight availability. Moreover the role played by the transition temperature of the pane is examined, pointing out an optimal transition temperatures that is irrespective of the climatic conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We synthesize the literature on Chinese multinational enterprises (MNEs) and find that much of the prior research is based on as few as a dozen case studies of Chinese firms. They are so case-specific that it has led to a misplaced call for new theories to explain Chinese firms’ internationalization. In an attempt to better relate theory with empirical evidence, we examine the largest 500 Chinese manufacturing firms. We aim to find out the number of Chinese manufacturing firms to be true MNEs by definition, and to examine their financial performance relative to global peers using the financial benchmarking method. We develop our theoretical perspectives from new internalization theory. We find that there are only 49 Chinese manufacturing firms to be true MNEs, whereas the rest is purely domestic firms. Their performance is poor relative to global peers. Chinese MNEs have home country bound firm-specific advantages (FSAs), which are built upon home country-specific advantages (home CSAs). They have not yet developed advanced management capabilities through recombination with host CSAs. Essentially, they acquire foreign firms to increase their sales in domestic market, but they fail to be competitive internationally and to achieve superior performance in overseas operations. Our findings have important strategic implications for managers, public policy makers, and academic research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cool materials are characterized by having a high solar reflectance r – which is able to reduce heat gains during daytime - and a high thermal emissivity ε that enables them to dissipate the heat absorbed throughout the day during night. Despite the concept of cool roofs - i.e. the application of cool materials to roof surfaces - is well known in US since 1990s, many studies focused on their performance in both residential and commercial sectors under various climatic conditions for US countries, while only a few case studies are analyzed in EU countries. The present work aims at analyzing the thermal benefits due to their application to existing office buildings located in EU countries. Indeed, due to their weight in the existing buildings stock, as well as the very low rate of new buildings construction, the retrofit of office buildings is a topic of great concern worldwide. After an in-depth characterization of the existing buildings stock in the EU, the book gives an insight into roof energy balance due to different technological solutions, showing in which cases and to what extent cool roofs are preferable. A detailed description of the physical properties of cool materials and their availability on the market provides a solid background for the parametric analysis carried out by means of detailed numerical models that aims at evaluating cool roofs performance for various climates and office buildings configurations. With the help of dynamic simulations, the thermal behavior of representative office buildings of the existing EU buildings stock is assessed in terms of thermal comfort and energy needs for air conditioning. The results, which consider several variations of building features that may affect the resulting energy balance, show how cool roofs are an effective strategy for reducing overheating occurrences and thus improving thermal comfort in any climate. On the other hand, potential heating penalties due to a reduction in the incoming heat fluxes through the roof are taken into account, as well as the aging process of cool materials. Finally, an economic analysis of the best performing models shows the boundaries for their economic convenience.