15 resultados para Hot water
em CentAUR: Central Archive University of Reading - UK
Resumo:
To achieve CO2 emissions reductions the UK Building Regulations require developers of new residential buildings to calculate expected CO2 emissions arising from their energy consumption using a methodology such as Standard Assessment Procedure (SAP 2005) or, more recently SAP 2009. SAP encompasses all domestic heat consumption and a limited proportion of the electricity consumption. However, these calculations are rarely verified with real energy consumption and related CO2 emissions. This paper presents the results of an analysis based on weekly head demand data for more than 200 individual flats. The data is collected from recently built residential development connected to a district heating network. A methodology for separating out the domestic hot water use (DHW) and space heating demand (SH) has been developed and compares measured values to the demand calculated using SAP 2005 and 2009 methodologies. The analysis shows also the variance in DHW and SH consumption between both size of the flats and tenure (privately owned or housing association). Evaluation of the space heating consumption includes also an estimation of the heating degree day (HDD) base temperature for each block of flats and its comparison to the average base temperature calculated using the SAP 2005 methodology.
Resumo:
Washing machine and dishwasher appliance use accounts for approximately 10% of electricity demand in EU households. The majority of this demand is due to the operation of electric heating elements inside appliances. This paper investigates the potential benefits that can be realised by adding a hot fill connection to washing appliances, with respect to carbon emissions, demand side management and renewable energy integration. Initial laboratory testing of new hot and cold fill appliances has resulted in modifications to optimise hot fill intake, and a novel numerical model presents a method of characterising appliance electricity use in different configurations. In order to validate model findings and test the use of new hot fill appliances in situ, a pilot study has recorded appliances’ resource consumption at one-minute resolution in fourteen households. The addition of hot fill reduced the total dishwasher and washing machine electricity consumption by 38% and 67% respectively. Depending on how hot water is supplied to appliances it is estimated that hot fill use results in an annual household carbon saving of up to 147 kgCO2. Further to direct electricity reduction, hot fill appliances can offer a method of time shifting demand away from peak periods without inconveniencing occupants’ lifestyles.
Resumo:
This paper presents the results of performance monitoring under real winter weather conditions, controlled laboratory testing and computational fluid dynamics (CFD) analysis of a wall mounted ventilation air inlet heat convector. For real winter weather monitoring, the wall-mounted convector was installed in a laboratory room of the Engineering Building of the School of Construction Management and Engineering. Air and hot water temperatures and air speeds were measured at the entrance to the convector and in the room. The hot water temperature was controlled at 40, 60 and 80 °C. The monitoring results were later used as boundary conditions for a CFD simulation to investigate the air movement in the room. Controlled laboratory testing was conducted in laboratories at the University of Reading, UK and at Wetterstad Consultancy, Sweden. The results of the performance investigation showed that the system contributed greatly to the room heating, particularly at a water temperature of 80 °C. Also adequate fresh air was supplied to the room. Such a system is able to provide an energy efficient method of eliminating problems associated with cold winter draughts.
Resumo:
There are varieties of physical and behavioral factors to determine energy demand load profile. The attainment of the optimum mix of measures and renewable energy system deployment requires a simple method suitable for using at the early design stage. A simple method of formulating load profile (SMLP) for UK domestic buildings has been presented in this paper. Domestic space heating load profile for different types of houses have been produced using thermal dynamic model which has been developed using thermal resistant network method. The daily breakdown energy demand load profile of appliance, domestic hot water and space heating can be predicted using this method. The method can produce daily load profile from individual house to urban community. It is suitable to be used at Renewable energy system strategic design stage.
Resumo:
Postharvest quality of Alphonso mangoes (Mangifera indica L) is vital to ensure proper ripening and good quality. 500 g mature green mangoes, were subjected to three pre- packaging hot water dips (20, 30 & 40°C) for 40 min, two packaging films (OPP unperforated and perforated), using three levels of gas concentrations of 25,50 and 75% v/v CO2 treatments (balance N2) and stored at 10°C for 21 days. During the storage period headspace gas composition, weight loss, ascorbic acid, pulp firmness, external fruit colour and overall quality score were measured to determine optimum storage conditions. The most effective postharvest condition was found to be dipping in water maintained at 40°C for 40 min, followed by packaging under 50% CO2 in bags made of unperforated film when compared to mangoes packed under 25 and 75% CO2 which showed deteriorated quality including spoilage and mould. Good keeping quality of at least 21 days was achieved under these conditions, which was much superior to the control samples that showed deterioration after 12 days of storage.
Resumo:
This paper arises from a doctoral thesis comparing the impact of alternative installer business models on the rate at which microgeneration is taken up in homes and installation standards across the UK. The paper presents the results of the first large-scale academic survey of businesses certified to install residential microgeneration. The aim is to systematically capture those characteristics which define the business model of each surveyed company, and relate these to the number, location and type of technologies that they install, and the quality of these installations. The methodology comprised a pilot web survey of 235 certified installer businesses, which was carried out in June last year and achieved a response rate of 30%. Following optimisation of the design, the main web survey was emailed to over 2000 businesses between October and December 2011, with 317 valid responses received. The survey is being complemented during summer 2012 by semi-structured interviews with a representative sample of installers who completed the main survey. The survey results are currently being analysed. The early results indicate an emerging and volatile market where solar PV, solar hot water and air source heat pumps are the dominant technologies. Three quarters of respondents are founders of their installer business, while only 22 businesses are owned by another company. Over half of the 317 businesses have five employees or less, while 166 businesses are no more than four years old. In addition, half of the businesses stated that 100% of their employees work on microgeneration-related activities. 85% of the surveyed companies have only one business location in the UK. A third of the businesses are based either in the South West or South East regions of England. This paper outlines the interim results of the survey combined with the outcomes from additional interviews with installers to date. The research identifies some of the business models underpinning microgeneration installers and some of the ways in which installer business models impact on the rate and standards of microgeneration uptake. A tentative conclusion is that installer business models are profoundly dependent on the levels and timing of support from the UK Feed-in Tariffs and Renewable Heat Incentive.
Resumo:
This review investigates the performance of photovoltaic and solar-assisted ground-source heat pumps in which solar heat is transferred to the ground to improve the coefficient of performance. A number of studies indicate that, for systems with adequately sized ground heat exchangers, the effect on system efficiency is small: about 1% improvement if the heat source is photovoltaic, a 1–2% decline if the source is solar thermal. With possible exceptions for systems in which the ground heat exchanger is undersized, or natural recharge from ground water is insufficient, solar thermal energy is better used for domestic hot water than to recharge ground heat. This appears particularly true outside the heating season, as although much of the heat extracted from the ground can be replaced, it seems to have little effect on the coefficient of performance. Any savings in electrical consumption that do result from an improved coefficient can easily be outweighed by an inefficient control system for the circulation pumps.
Resumo:
Collectively small and medium sized enterprises (SMEs) are significant energy users although many are unregulated by existing policies due to their low carbon emissions. Carbon reduction is often not a priority but smart grids may create a new opportunity. A smart grid will give electricity suppliers a picture of real-time energy flows and the opportunity for consumers to receive financial incentives for engaging in demand side management. As well as creating incentives for local carbon reduction, engaging SMEs with smart grids has potential for contributing to wider grid decarbonisation. Modelling of buildings, business activities and technology solutions is needed to identify opportunities for carbon reduction. The diversity of the SME sector complicates strategy development. SMEs are active in almost every business area and occupy the full range of property types. This paper reviews previous modelling work, exposing valuable data on floor space and energy consumption associated with different business activities. Limitations are seen with the age of this data and an inability to distinguish SME energy use. By modelling SME energy use, electrical loads are identified which could be shifted on demand, in a smart network. Initial analysis of consumption, not constrained by existing policies, identifies heating and cooling in retail and commercial offices as having potential for demand response. Hot water in hotel and catering and retail sectors may also be significant because of the energy storage potential. Areas to consider for energy efficiency schemes are also indicated.
Resumo:
This study analyses soil organic carbon (SOC) and hot-water extractable carbon (HWC), both measures of soil quality, under different land management: (1) conventional tillage (CT); (2) CT plus the addition of oil mill waste alperujo (A); (3) CT plus the addition of oil mill waste olive leaves (L); (4) no tillage with chipped pruned branches (NT1); and (5) no tillage with chipped pruned branches and weeds (NT2); in a typical Mediterranean agricultural area; the olive groves of Andalucía, southern Spain. SOC values in CT, A, NT1 and NT2 decreased with depth, but in NT2 the surface horizon (0-5 cm) had higher values than the other treatments, 47% more than the average values in the other three soils. In L, SOC also decreased with depth, although there was an increase of 88.5% from the first (0-10 cm) to the second horizon (10-16 cm). Total SOC stock values were very similar under A (101.9 Mg ha−1), CT (101.7 Mg ha−1), NT1 (105.8 Mg ha−1) and NT2 (111.3 Mg ha−1, if we consider the same depth of the others). However, SOC under L was significantly higher (p < 0.05) at 250.2 Mg ha−1. HWC decreased with depth in A, CT and NT1. NT2 and L followed the same pattern as the other management types but with a higher value in the surface horizon (2.3 and 4.9 mg g−1 respectively). Overall, our results indicate that application of oil mill waste olive leaves under CT (L) is a good management practice to improve SOC and reduce waste.
Resumo:
A ground source heat pump assisted by an array of photovoltaic (PV)-thermal modules was studied in this work. Extracting heat from an array of PV modules should improve the performance of both the PV cells and the heat pump. A series of computer simulations compare the performance of a ground source heat pump with a short ground circuit, used to provide space heating and domestic hot water at a house in southern England. The results indicate that extracting heat from an array of PV-thermal modules would improve the performance of a ground source heat pump with an undersized ground loop. Nevertheless, open air thermal collectors could be more effective, especially during winter. In one model more electricity was saved in ohmic heating than was generated by cooling the PV cells. Cooling the PV modules was found to increase their electrical output up to 4%, but much of the extra electricity was consumed by the cooling pumps.
Resumo:
Data on electricity consumption patterns relating to different end uses in domestic houses in Botswana is virtually non-existent, despite the fact that the total electricity consumption patterns are available. This can be attributed to the lack of measured and quantified data and in other instances the lack of modern technology to perform such investigations. This paper presents findings from initial studies that are envisaged to bridge the gap. Electricity consumption patterns of 275 domestic households in Gaborone (the capital city of Botswana) have been studied. This was carried out through a questionnaire survey and electricity measurements. Households were categorized based on the number of people occupying the house. From the study, it was evident that the number of people influences the amount of energy a household use although this cannot be treated as an independent factor when assessing energy use. The study also indicated that heating, cooling and domestic hot water (DHW) account for over 30% of energy used in the home. This is worth considering in energy consumption reduction measures. Due to a small sample size, it would not be wise to draw sweeping conclusions from the analysis of this paper or to make statements that would be aimed at influencing policies. However, the results presented forms a formidable base for further research, which is currently on going.
Resumo:
Soil organic matter (SOM) is one of the main global carbon pools. It is a measure of soil quality as its presence increases carbon sequestration and improves physical and chemical soil properties. The determination and characterisation of humic substances gives essential information of the maturity and stresses of soils as well as of their health. However, the determination of the exact nature and molecular structure of these substances has been proven difficult. Several complex techniques exist to characterise SOM and mineralisation and humification processes. One of the more widely accepted for its accuracy is nuclear magnetic resonance (NMR) spectroscopy. Despite its efficacy, NMR needs significant economic resources, equipment, material and time. Proxy measures like the fluorescence index (FI), cold and hot-water extractable carbon (CWC and HWC) and SUVA-254 have the potential to characterise SOM and, in combination, provide qualitative and quantitative data of SOM and its processes. Spanish and British agricultural cambisols were used to measure SOM quality and determine whether similarities were found between optical techniques and 1H NMR results in these two regions with contrasting climatic conditions. High correlations (p < 0.001) were found between the specific aromatic fraction measured with 1H NMR and SUVA-254 (Rs = 0.95) and HWC (Rs = 0.90), which could be described using a linear model. A high correlation between FI and the aromatics fraction measured with 1H NMR (Rs = −0.976) was also observed. In view of our results, optical measures have a potential, in combination, to predict the aromatic fraction of SOM without the need of expensive and time consuming techniques.
Resumo:
Archived soils could represent a valuable resource for the spatio-temporal inventory of soil carbon stability. However, archived soils are usually air-dried before storage and the impact of a drying pretreatment on physically and chemically-defined C fractions has not yet been fully assessed. Through the comparison of field-moist and corresponding air-dried (at 25oC for 2 weeks) forest soil samples, we examined the effect of air-drying on: a) the quantity and the quality of cold- (CWEC) and hot-water (HWEC) extractable C and b) the concentration of C in physically isolated fractions (free- and intra-aggregate light and organo-mineral). Soil samples were collected from the organic (O) and mineral (A and B) horizons of three different forest soils from southeastern England: (i) Cambisol under Pine (Pinus nigra); (ii) Cambisol under Beech (Fagus sylvatica) and (iii) Gleysol under oak (Quercus robur). CWEC concentrations for dry samples were up to 2 times greater than for corresponding field moist samples and had significantly (p < 0.001) higher phenolic content. However, the effect of drying pretreatment on HWEC, its phenolic content was not significant (p > 0.05) for most samples. Dried soils had significantly (p < 0.001) higher concentrations of free light-C while having lower concentrations of intra-aggregate-C when compared to moist samples (p < 0.001). However, fine silt and clay fractions were not significantly affected by the drying pretreatment (p=0.789). Therefore, based on the results obtained from gleysol and cambisol forest soils studied here, C contents in hot-water extractions and fine particle size physical fractions (< 25µm) seem to be robust measurements for evaluating C fractions in dried stored forest soils. Further soil types should be tested to evaluate the wider generality of these findings.
Resumo:
A strong climatic warming is currently observed in the Caucasus mountains, which has profound impact on runoff generation in the glaciated Glavny (Main) Range and on water availability in the whole region. To assess future changes in the hydrological cycle, the output of a general circulation model was downscaled statistically. For the 21st century, a further warming by 4–7 °C and a slight precipitation increase is predicted. Measured and simulated meteorological variables were used as input into a runoff model to transfer climate signals into a hydrological response under both present and future climate forcings. Runoff scenarios for the mid and the end of the 21st century were generated for different steps of deglaciation. The results show a satisfactory model performance for periods with observed runoff. Future water availability strongly depends on the velocity of glacier retreat. In a first phase, a surplus of water will increase flood risk in hot years and after continuing glacier reduction, annual runoff will again approximate current values. However, the seasonal distribution of streamflow will change towards runoff increase in spring and lower flows in summer.
Resumo:
We present an analysis of seven primary transit observations of the hot Neptune GJ436b at 3.6, 4.5, and 8 μm obtained with the Infrared Array Camera on the Spitzer Space Telescope. After correcting for systematic effects, we fitted the light curves using the Markov Chain Monte Carlo technique. Combining these new data with the EPOXI, Hubble Space Telescope, and ground-based V, I, H, and Ks published observations, the range 0.5-10 μm can be covered. Due to the low level of activity of GJ436, the effect of starspots on the combination of transits at different epochs is negligible at the accuracy of the data set. Representative climate models were calculated by using a three-dimensional, pseudospectral general circulation model with idealized thermal forcing. Simulated transit spectra of GJ436b were generated using line-by-line radiative transfer models including the opacities of the molecular species expected to be present in such a planetary atmosphere. A new, ab-initio-calculated, line list for hot ammonia has been used for the first time. The photometric data observed at multiple wavelengths can be interpreted with methane being the dominant absorption after molecular hydrogen, possibly with minor contributions from ammonia, water, and other molecules. No clear evidence of carbon monoxide and carbon dioxide is found from transit photometry. We discuss this result in the light of a recent paper where photochemical disequilibrium is hypothesized to interpret secondary transit photometric data. We show that the emission photometric data are not incompatible with the presence of abundant methane, but further spectroscopic data are desirable to confirm this scenario.