17 resultados para Green buildings

em CentAUR: Central Archive University of Reading - UK


Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is necessary to minimize the environmental impact and utilize natural resources in a sustainable and efficient manner in the early design stage of developing an environmentally-conscious design for a heating, ventilating and air-conditioning system. Energy supply options play a significant role in the total environmental load of heating, ventilating and air-conditioning systems. To assess the environmental impact of different energy options, a new method based on Emergy Analysis is proposed. Emergy Accounting, was first developed and widely used in the area of ecological engineering, but this is the first time it has been used in building service engineering. The environmental impacts due to the energy options are divided into four categories under the Emergy Framework: the depletion of natural resources, the greenhouse effect (carbon dioxide equivalents), the chemical rain effect (sulphur dioxide equivalents), and anthropogenic heat release. The depletion of non-renewable natural resources is indicated by the Environmental Load Ratio, and the environmental carrying capacity is developed to represent the environmental service to dilute the pollutants and anthropogenic heat released. This Emergy evaluation method provides a new way to integrate different environmental impacts under the same framework and thus facilitates better system choices. A case study of six different kinds of energy options consisting of renewable and non-renewable energy was performed by using Emergy Theory, and thus their relative environmental impacts were compared. The results show that the method of electricity generation in energy sources, especially for electricity-powered systems, is the most important factor to determine their overall environmental performance. The direct-fired lithium-bromide absorption type consumes more non-renewable energy, and contributes more to the urban heat island effect compared with other options having the same electricity supply. Using Emergy Analysis, designers and clients can make better-informed, environmentally-conscious selections of heating, ventilating and air-conditioning systems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We have developed a model that allows players in the building and construction sector and the energy policy makers on energy strategies to be able to perceive the interest of investors in the kingdom of Bahrain in conducting Building Integrated Photovoltaic (BIPV) or Building integrated wind turbines (BIWT) projects, i.e. a partial sustainable or green buildings. The model allows the calculation of the Sustainable building index (SBI), which ranges from 0.1 (lowest) to 1.0 (highest); the higher figure the more chance for launching BIPV or BIWT. This model was tested in Bahrain and the calculated SBI was found 0.47. This means that an extensive effort must be made through policies on renewable energy, renewable energy education, and incentives to BIPV and BIWT projects, environmental awareness and promotion to clean and sustainable energy for building and construction projects. Our model can be used internationally to create a "Global SBI" database. The Sustainable building and construction initiative (SBCI), United Nation, can take the task for establishing such task using this model.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effects and influence of the Building Research Establishment’s Environmental Assessment Methods (BREEAM) on construction professionals are examined. Most discussions of building assessment methods focus on either the formal tool or the finished product. In contrast, BREEAM is analysed here as a social technology using Michel Foucault’s theory of governmentality. Interview data are used to explore the effect of BREEAM on visibilities, knowledge, techniques and professional identities. The analysis highlights a number of features of the BREEAM assessment process which generally go unremarked: professional and public understandings of the method, the deployment of different types of knowledge and their implication for the authority and legitimacy of the tool, and the effect of BREEAM on standard practice. The analysis finds that BREEAM’s primary effect is through its impact on standard practices. Other effects include the use of assessment methods to defend design decisions, its role in both operationalizing and obscuring the concept of green buildings, and the effect of tensions between project and method requirements for the authority of the tool. A reflection on assessment methods as neo-liberal tools and their adequacy for the promotion of sustainable construction suggests several limitations of lock-in that hinder variation and wider systemic change.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Energy use intensity (EUI) and climate have a well documented correlation, which is generally applied in building energy management. Green buildings have sought to greatly reduce energy consumption and a number of examples are documented in the literature. A sample of high performance buildings constructed in a variety of global locations is analyzed here, and provides evidence that measures to reduce energy consumption have reduced EUI to the point where its correlation with heating degree days is no longer apparent. This result suggests that end-user behaviour is the next major hurdle in lowering the energy consumption of greener buildings.

Relevância:

40.00% 40.00%

Publicador:

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper investigates the price effects of environmental certification on commercial real estate assets. It is argued that there are likely to be three main drivers of price differences between certified and non-certified buildings. First, certified buildings offer a bundle of benefits to occupiers relating to business productivity, image and occupancy costs. Second, due to these occupier benefits, certified buildings can result in higher rents and lower holding costs for investors. Third, certified buildings may require a lower risk premium. Drawing upon the CoStar database of US commercial real estate assets, hedonic regression analysis is used to measure the effect of certification on both rent and price. We first estimate the rental regression for a sample of 110 LEED and 433 Energy Star as well as several thousand benchmark buildings to compare the sample to. The results suggest that, compared to buildings in the same metropolitan region, certified buildings have a rental premium and that the more highly rated that buildings are in terms of their environmental impact, the greater the rental premium. Furthermore, based on a sample of transaction prices for 292 Energy Star and 30 LEED-certified buildings, we find price premia of 10% and 31% respectively compared to non-certified buildings in the same metropolitan area

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The intensification of the Urban Heat Island effect (UHI) is a problem that involves several fields, and new adequate solutions are required to mitigate its amplitude. The construction sector is strictly related with this phenomenon; in particular, roofs are the envelope components subject to the highest solar irradiance, hence any mitigation strategy should start from them and involve their appropriate design process. For this purpose, cool materials, i.e. materials which are able to reflect a large amount of solar radiation and avoid overheating of building surfaces have been deeply analyzed in the last years both at building and urban scales, showing their benefits especially in hot climates. However, green roofs also represent a possible way to cope with UHI, even if their design is not straightforward and requires taking into account many variables, strictly related with the local climatic conditions. In this context, the present paper proposes a comparison between cool roofs and green roofs for several Italian cities that are representative of different climatic conditions. In search of the most effective solution, the answers may be different depending on the perspective that leads the comparison, i.e. the need to reduce the energy consumption in buildings or the desire to minimize the contribution of the UHI effect.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the main changes of Commons Act 2006 for the registration of land as a town or village green. The purpose of the Commons Act 2006 is to protect common land and promote sustainable farming, public access to the countryside and the interests of wildlife. The changes under s15 of the Commons Act 2006 include the additional 2-year grace period for application, discounting statutory period of closure, correction of mistakes in registers, disallowing severance of rights, voluntary registration, replacement of land in exchange and some other provisions. The transitional provision contained in s15(4) Commons Act 2006 is particularly a cause for controversy as DEFRA has indicated buildings will have to be taken down where development has gone ahead and a subsequent application to register the land as a green is successful, obliging the developer to return the land to a condition consistent with the exercise by locals of recreational rights, which sums up that it would be harder in future to develop land which has the potential to be registered as a town or village green.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigates the price effects of environmental certification on commercial real estate assets. It is argued that there are likely to be three main drivers of price differences between certified and noncertified buildings. These are additional occupier benefits, lower holding costs for investors and a lower risk premium. Drawing upon the CoStar database of U.S. commercial real estate assets, hedonic regression analysis is used to measure the effect of certification on both rent and price. The results suggest that, compared to buildings in the same submarkets, eco-certified buildings have both a rental and sale price premium.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates the effect of voluntary eco-certification on the rental and sale prices of US commercial office properties. Hedonic and logistic regressions are used to test whether there are rental and sale price premiums for LEED and Energy Star certified buildings. The results of the hedonic analysis suggest that there is a rental premium of approximately 6% for LEED and Energy Star certification. A sale price premium of approximately 35% was found for 127 price observations involving LEED rated buildings and 31% for 662 buildings involving Energy Star rated buildings. When compared to samples of similar buildings identified by a binomial logistic regression for LEED-certified buildings, the existence of a rent and sales price premium is confirmed albeit with differences regarding the magnitude of the premium. Overall, the results of this study confirm that LEED and Energy Star buildings exhibit higher rental rates and sales prices per square foot controlling for a large number of location- and property-specific factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Current approaches for the reduction of carbon emissions in buildings are often predicated on the integration of renewable technologies into building projects. Building integrated photovoltaics (BIPV) is one of these technologies and brings its own set of challenges and problems with a resulting mutual articulation of this technology and the building. A Social Construction of Technology (SCOT) approach explores how negotiations between informal groups of project actors with shared interests shape the ongoing specification of both BIPV and the building. Six main groups with different interests were found to be involved in the introduction of BIPV (Cost Watchers, Design Aesthetes, Green Guardians, Design Optimizers, Generation Maximizers and Users). Their involvement around three sets of issues (design changes from lack of familiarity with the technology, misunderstandings from unfamiliar interdependencies of trades and the effects of standard firm procedure) is followed. Findings underline how BIPV requires a level of integration that typically spans different work packages and how standard contractual structures inhibit the smooth incorporation of BIPV. Successful implementation is marked by ongoing (re-)design of both the building and the technology as informal fluid groups of project actors with shared interests address the succession of problems which arise in the process of implementation.