121 resultados para Eye Refractive errors
em CentAUR: Central Archive University of Reading - UK
Resumo:
Purpose. Accommodation can mask hyperopia and reduce the accuracy of non-cycloplegic refraction. It is, therefore, important to minimize accommodation to obtain a measure of hyperopia as accurate as possible. To characterize the parameters required to measure the maximally hyperopic error using photorefraction, we used different target types and distances to determine which target was most likely to maximally relax accommodation and thus more accurately detect hyperopia in an individual. Methods. A PlusoptiX SO4 infra-red photorefractor was mounted in a remote haploscope which presented the targets. All participants were tested with targets at four fixation distances between 0.3 and 2 m containing all combinations of blur, disparity, and proximity/looming cues. Thirty-eight infants (6 to 44 weeks) were studied longitudinally, and 104 children [4 to 15 years (mean 6.4)] and 85 adults, with a range of refractive errors and binocular vision status, were tested once. Cycloplegic refraction data were available for a sub-set of 59 participants spread across the age range. Results. The maximally hyperopic refraction (MHR) found at any time in the session was most frequently found when fixating the most distant targets and those containing disparity and dynamic proximity/looming cues. Presence or absence of blur was less significant, and targets in which only single cues to depth were present were also less likely to produce MHR. MHR correlated closely with cycloplegic refraction (r = 0.93, mean difference 0.07 D, p = n.s., 95% confidence interval +/-<0.25 D) after correction by a calibration factor. Conclusions. Maximum relaxation of accommodation occurred for binocular targets receding into the distance. Proximal and disparity cues aid relaxation of accommodation to a greater extent than blur, and thus non-cycloplegic refraction targets should incorporate these cues. This is especially important in screening contexts with a brief opportunity to test for significant hyperopia. MHR in our laboratory was found to be a reliable estimation of cycloplegic refraction. (Optom Vis Sci 2009;86:1276-1286)
Resumo:
Eye-movements have long been considered a problem when trying to understand the visual control of locomotion. They transform the retinal image from a simple expanding pattern of moving texture elements (pure optic flow), into a complex combination of translation and rotation components (retinal flow). In this article we investigate whether there are measurable advantages to having an active free gaze, over a static gaze or tracking gaze, when steering along a winding path. We also examine patterns of free gaze behavior to determine preferred gaze strategies during active locomotion. Participants were asked to steer along a computer-simulated textured roadway with free gaze, fixed gaze, or gaze tracking the center of the roadway. Deviation of position from the center of the road was recorded along with their point of gaze. It was found that visually tracking the middle of the road produced smaller steering errors than for fixed gaze. Participants performed best at the steering task when allowed to sample naturally from the road ahead with free gaze. There was some variation in the gaze strategies used, but sampling was predominantly of areas proximal to the center of the road. These results diverge from traditional models of flow analysis.
Resumo:
A robot mounted camera is useful in many machine vision tasks as it allows control over view direction and position. In this paper we report a technique for calibrating both the robot and the camera using only a single corresponding point. All existing head-eye calibration systems we have encountered rely on using pre-calibrated robots, pre- calibrated cameras, special calibration objects or combinations of these. Our method avoids using large scale non-linear optimizations by recovering the parameters in small dependent groups. This is done by performing a series of planned, but initially uncalibrated robot movements. Many of the kinematic parameters are obtained using only camera views in which the calibration feature is at, or near the image center, thus avoiding errors which could be introduced by lens distortion. The calibration is shown to be both stable and accurate. The robotic system we use consists of camera with pan-tilt capability mounted on a Cartesian robot, providing a total of 5 degrees of freedom.
Resumo:
Aim: To determine the prevalence and nature of prescribing errors in general practice; to explore the causes, and to identify defences against error. Methods: 1) Systematic reviews; 2) Retrospective review of unique medication items prescribed over a 12 month period to a 2% sample of patients from 15 general practices in England; 3) Interviews with 34 prescribers regarding 70 potential errors; 15 root cause analyses, and six focus groups involving 46 primary health care team members Results: The study involved examination of 6,048 unique prescription items for 1,777 patients. Prescribing or monitoring errors were detected for one in eight patients, involving around one in 20 of all prescription items. The vast majority of the errors were of mild to moderate severity, with one in 550 items being associated with a severe error. The following factors were associated with increased risk of prescribing or monitoring errors: male gender, age less than 15 years or greater than 64 years, number of unique medication items prescribed, and being prescribed preparations in the following therapeutic areas: cardiovascular, infections, malignant disease and immunosuppression, musculoskeletal, eye, ENT and skin. Prescribing or monitoring errors were not associated with the grade of GP or whether prescriptions were issued as acute or repeat items. A wide range of underlying causes of error were identified relating to the prescriber, patient, the team, the working environment, the task, the computer system and the primary/secondary care interface. Many defences against error were also identified, including strategies employed by individual prescribers and primary care teams, and making best use of health information technology. Conclusion: Prescribing errors in general practices are common, although severe errors are unusual. Many factors increase the risk of error. Strategies for reducing the prevalence of error should focus on GP training, continuing professional development for GPs, clinical governance, effective use of clinical computer systems, and improving safety systems within general practices and at the interface with secondary care.
Resumo:
Data assimilation provides techniques for combining observations and prior model forecasts to create initial conditions for numerical weather prediction (NWP). The relative weighting assigned to each observation in the analysis is determined by its associated error. Remote sensing data usually has correlated errors, but the correlations are typically ignored in NWP. Here, we describe three approaches to the treatment of observation error correlations. For an idealized data set, the information content under each simplified assumption is compared with that under correct correlation specification. Treating the errors as uncorrelated results in a significant loss of information. However, retention of an approximated correlation gives clear benefits.
Resumo:
Using a flexible chemical box model with full heterogeneous chemistry, intercepts of chemically modified Langley plots have been computed for the 5 years of zenith-sky NO2 data from Faraday in Antarctica (65°S). By using these intercepts as the effective amount in the reference spectrum, drifts in zero of total vertical NO2 were much reduced. The error in zero of total NO2 is ±0.03×1015 moleccm−2 from one year to another. This error is small enough to determine trends in midsummer and any variability in denoxification between midwinters. The technique also suggests a more sensitive method for determining N2O5 from zenith-sky NO2 data.
Resumo:
In an immersive virtual environment, observers fail to notice the expansion of a room around them and consequently make gross errors when comparing the size of objects. This result is difficult to explain if the visual system continuously generates a 3-D model of the scene based on known baseline information from interocular separation or proprioception as the observer walks. An alternative is that observers use view-based methods to guide their actions and to represent the spatial layout of the scene. In this case, they may have an expectation of the images they will receive but be insensitive to the rate at which images arrive as they walk. We describe the way in which the eye movement strategy of animals simplifies motion processing if their goal is to move towards a desired image and discuss dorsal and ventral stream processing of moving images in that context. Although many questions about view-based approaches to scene representation remain unanswered, the solutions are likely to be highly relevant to understanding biological 3-D vision.
Resumo:
The amygdala was more responsive to fearful (larger) eye whites than to happy (smaller) eye whites presented in a masking paradigm that mitigated subjects' awareness of their presence and aberrant nature. These data demonstrate that the amygdala is responsive to elements of.