8 resultados para Experimental techniques

em CentAUR: Central Archive University of Reading - UK


Relevância:

70.00% 70.00%

Publicador:

Resumo:

1. Suction sampling is a popular method for the collection of quantitative data on grassland invertebrate populations, although there have been no detailed studies into the effectiveness of the method. 2. We investigate the effect of effort (duration and number of suction samples) and sward height on the efficiency of suction sampling of grassland beetle, true bug, planthopper and spider Populations. We also compare Suction sampling with an absolute sampling method based on the destructive removal of turfs. 3. Sampling for durations of 16 seconds was sufficient to collect 90% of all individuals and species of grassland beetles, with less time required for the true bugs, spiders and planthoppers. The number of samples required to collect 90% of the species was more variable, although in general 55 sub-samples was sufficient for all groups, except the true bugs. Increasing sward height had a negative effect on the capture efficiency of suction sampling. 4. The assemblage structure of beetles, planthoppers and spiders was independent of the sampling method (suction or absolute) used. 5. Synthesis and applications. In contrast to other sampling methods used in grassland habitats (e.g. sweep netting or pitfall trapping), suction sampling is an effective quantitative tool for the measurement of invertebrate diversity and assemblage structure providing sward height is included as a covariate. The effective sampling of beetles, true bugs, planthoppers and spiders altogether requires a minimum sampling effort of 110 sub-samples of duration of 16 seconds. Such sampling intensities can be adjusted depending on the taxa sampled, and we provide information to minimize sampling problems associated with this versatile technique. Suction sampling should remain an important component in the toolbox of experimental techniques used during both experimental and management sampling regimes within agroecosystems, grasslands or other low-lying vegetation types.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper considers ways that experimental design can affect judgments about informally presented context shifting experiments. Reasons are given to think that judgments about informal context shifting experiments are affected by an exclusive reliance on binary truth value judgments and by experimenter bias. Exclusive reliance on binary truth value judgments may produce experimental artifacts by obscuring important differences of degree between the phenomena being investigated. Experimenter bias is an effect generated when, for example, experimenters disclose (even unconsciously) their own beliefs about the outcome of an experiment. Eliminating experimenter bias from context shifting experiments makes it far less obvious what the “intuitive” responses to those experiments are. After it is shown how those different kinds of bias can affect judgments about informal context shifting experiments, those experiments are revised to control for those forms of bias. The upshot of these investigations is that participants in the contextualist debate who employ informal experiments should pay just as much attention to the design of their experiments as those who employ more formal experimental techniques if they want to avoid obscuring the phenomena they aim to uncover

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In recent years, our increased understanding of the complex signal transduction mechanisms that regulate cellular function has fueled huge advances in all aspects of biomedical science and cell biology. Platelet and megakaryocyte function is no exception to this. In the last 10 yr our understanding of the receptor biochemistry and the systems that they control has been pivotal in the development of new strategies to inhibit platelet function and thereby prevent thrombosis. Experimental techniques have become more and more elegant, however; the basic toolbox that a researcher requires to study signaling in platelets and megakaryoctes is described in this and several subsequent chapters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Molecular dynamics simulations of the events after the photodissociation of CO in the myoglobin mutant L29F in which leucine is replaced by phenylalanine are reported. Using both classical and mixed quantum-classical molecular dynamics calculations, we observed the rapid motion of CO away from the distal heme pocket to other regions of the protein, in agreement with recent experimental results. The experimentally observed and calculated infrared spectra of CO after dissociation are also in good agreement. We compared the results with data from simulations of WT myoglobin. As the time resolution of experimental techniques is increased, theoretical methods and models can be validated at the atomic scale by direct comparison with experiment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Detailed understanding of the haemodynamic changes that underlie non-invasive neuroimaging techniques such as blood oxygen level dependent functional magnetic resonance imaging is essential if we are to continue to extend the use of these methods for understanding brain function and dysfunction. The use of animal and in particular rodent research models has been central to these endeavours as they allow in-vivo experimental techniques that provide measurements of the haemodynamic response function at high temporal and spatial resolution. A limitation of most of this research is the use of anaesthetic agents which may disrupt or mask important features of neurovascular coupling or the haemodynamic response function. In this study we therefore measured spatiotemporal cortical haemodynamic responses to somatosensory stimulation in awake rats using optical imaging spectroscopy. Trained, restrained animals received non-noxious stimulation of the whisker pad via chronically implanted stimulating microwires whilst optical recordings were made from the contralateral somatosensory cortex through a thin cranial window. The responses we measure from un-anaesthetised animals are substantially different from those reported in previous studies which have used anaesthetised animals. These differences include biphasic response regions (initial increases in blood volume and oxygenation followed by subsequent decreases) as well as oscillations in the response time series of awake animals. These haemodynamic response features do not reflect concomitant changes in the underlying neuronal activity and therefore reflect neurovascular or cerebrovascular processes. These hitherto unreported hyperemic response dynamics may have important implications for the use of anaesthetised animal models for research into the haemodynamic response function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Methodology used to measure in vitro gas production is reviewed to determine impacts of sources of variation on resultant gas production profiles (GPP). Current methods include measurement of gas production at constant pressure (e.g., use of gas tight syringes), a system that is inexpensive, but may be less sensitive than others thereby affecting its suitability in some situations. Automated systems that measure gas production at constant volume allow pressure to accumulate in the bottle, which is recorded at different times to produce a GPP, and may result in sufficiently high pressure that solubility of evolved gases in the medium is affected, thereby resulting in a recorded volume of gas that is lower than that predicted from stoichiometric calculations. Several other methods measure gas production at constant pressure and volume with either pressure transducers or sensors, and these may be manual, semi-automated or fully automated in operation. In these systems, gas is released as pressure increases, and vented gas is recorded. Agitating the medium does not consistently produce more gas with automated systems, and little or no effect of agitation was observed with manual systems. The apparatus affects GPP, but mathematical manipulation may enable effects of apparatus to be removed. The amount of substrate affects the volume of gas produced, but not rate of gas production, provided there is sufficient buffering capacity in the medium. Systems that use a very small amount of substrate are prone to experimental error in sample weighing. Effect of sample preparation on GPP has been found to be important, but further research is required to determine the optimum preparation that mimics animal chewing. Inoculum is the single largest source of variation in measuring GPP, as rumen fluid is variable and sampling schedules, diets fed to donor animals and ratios of rumen fluid/medium must be selected such that microbial activity is sufficiently high that it does not affect rate and extent of fermentation. Species of donor animal may also cause differences in GPP. End point measures can be mathematically manipulated to account for species differences, but rates of fermentation are not related. Other sources of inocula that have been used include caecal fluid (primarily for investigating hindgut fermentation in monogastrics), effluent from simulated rumen fermentation (e.g., 'Rusitec', which was as variable as rumen fluid), faeces, and frozen or freeze-dried rumen fluid (which were both less active than fresh rumen fluid). Use of mixtures of cell-free enzymes, or pure cultures of bacteria, may be a way of increasing GPP reproducibility, while reducing reliance on surgically modified animals. However, more research is required to develop these inocula. A number of media have been developed which buffer the incubation and provide relevant micro-nutrients to the microorganisms. To date, little research has been completed on relationships between the composition of the medium and measured GPP. However, comparing GPP from media either rich in N or N-free, allows assessment of contributions of N containing compounds in the sample. (c) 2005 Published by Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this review paper is to present experimental methodologies and the mathematical approaches used to determine effective diffusivities of solutes in food materials. The paper commences by describing the diffusion phenomena related to solute mass transfer in foods and effective diffusivities. It then focuses on the mathematical formulation for the calculation of effective diffusivities considering different diffusion models based on Fick's second law of diffusion. Finally, experimental considerations for effective diffusivity determination are elucidated primarily based on the acquirement of a series of solute content versus time curves appropriate to the equation model chosen. Different factors contributing to the determination of the effective diffusivities such as the structure of food material, temperature, diffusion solvent, agitation, sampling, concentration and different techniques used are considered. (c) 2005 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ruminant husbandry is a major source of anthropogenic greenhouse gases (GHG). Filling knowledge gaps and providing expert recommendation are important for defining future research priorities, improving methodologies and establishing science-based GHG mitigation solutions to government and non-governmental organisations, advisory/extension networks, and the ruminant livestock sector. The objectives of this review is to summarize published literature to provide a detailed assessment of the methodologies currently in use for measuring enteric methane (CH4) emission from individual animals under specific conditions, and give recommendations regarding their application. The methods described include respiration chambers and enclosures, sulphur hexafluoride tracer (SF6) technique, and techniques based on short-term measurements of gas concentrations in samples of exhaled air. This includes automated head chambers (e.g. the GreenFeed system), the use of carbon dioxide (CO2) as a marker, and (handheld) laser CH4 detection. Each of the techniques are compared and assessed on their capability and limitations, followed by methodology recommendations. It is concluded that there is no ‘one size fits all’ method for measuring CH4 emission by individual animals. Ultimately, the decision as to which method to use should be based on the experimental objectives and resources available. However, the need for high throughput methodology e.g. for screening large numbers of animals for genomic studies, does not justify the use of methods that are inaccurate. All CH4 measurement techniques are subject to experimental variation and random errors. Many sources of variation must be considered when measuring CH4 concentration in exhaled air samples without a quantitative or at least regular collection rate, or use of a marker to indicate (or adjust) for the proportion of exhaled CH4 sampled. Consideration of the number and timing of measurements relative to diurnal patterns of CH4 emission and respiratory exchange are important, as well as consideration of feeding patterns and associated patterns of rumen fermentation rate and other aspects of animal behaviour. Regardless of the method chosen, appropriate calibrations and recovery tests are required for both method establishment and routine operation. Successful and correct use of methods requires careful attention to detail, rigour, and routine self-assessment of the quality of the data they provide.