90 resultados para Energy performance rating
em CentAUR: Central Archive University of Reading - UK
Resumo:
This paper focuses on the effect of energy performance ratings on the capital values, rental values and equivalent yields of UK commercial property assets. Of which a small number are also BREEAM rated, the study is based upon 708 commercial property assets held in the IPD UK Universe drawn from across all PAS segments. Incorporating a range of controls such as unexpired lease term, vacancy rate and tenant credit risk, hedonic regression procedures are used to estimate the effect of EPC rating. The study finds no evidence of a strong relationship between environmental and/or energy performance and rental and capital value. Bearing in mind the small number of BREEAM rated assets, there was a small but statistically significant effect on equivalent yield only. Similarly, there was no evidence that the EPC rating had any effect on Market Rent or Market Value with only minor effects of EPC ratings on equivalent yields. The preliminary conclusion is that energy labelling is not yet having the effects on Market Values and Market Rents that provide incentives for market participants to improve the energy efficiency of their commercial real estate assets.
Resumo:
This paper investigates the price effect of EPC ratings on the residential dwelling prices in Wales. It examines the capitalisation of energy efficiency ratings into house prices using two approaches. The first adopts a cross-sectional framework to investigate the effect of EPC band (and EPC rating) on a large sample of dwelling transactions. The second approach is based on a repeat-sales methodology to examine the impact of EPC band and rating on house price appreciation. The results show that, controlling for other price influencing dwelling characteristics, EPC band does affect house prices. This observed influence of EPC on price may not be a result of energy performance alone; the effect may be due to non-energy related benefits associated with certain types, specifications and ages of dwellings or there may be unobserved quality differences unrelated to energy performance such as better quality fittings and materials. An analysis of the private rental segment reveals that, in contrast to the general market, low-EPC rated properties were not traded at a significant discount, suggesting different implicit prices of potential energy savings for landlords and owner-occupiers.
Resumo:
This paper investigates the effect of Energy Performance Certificate (EPC) ratings on residential prices in Wales. Drawing on a sample of approximately 192,000 transactions, the capitalisation of energy efficiency ratings into house prices is investigated using two approaches. The first adopts a cross-sectional framework to investigate the effect of EPC rating on price. The second approach applies a repeat-sales methodology to investigate the impact of EPC rating on house price appreciation. Statistically significant positive price premiums are estimated for dwellings in EPC bands A/B (12.8%) and C (3.5%) compared to houses in band D. For dwellings in band E (−3.6%) and F (−6.5%) there are statistically significant discounts. Such effects may not be the result of energy performance alone. In addition to energy cost differences, the price effect may be due to additional benefits of energy efficient features. An analysis of the private rental segment reveals that, in contrast to the general market, low-EPC rated dwellings were not traded at a significant discount. This suggests different implicit prices of potential energy savings for landlords and owner-occupiers.
Resumo:
Purpose – The paper aims to present the findings of a “situation review” of the Energy Performance of Buildings Directive (EPBD), focusing on energy performance certificates (EPCs) to highlight areas of specific importance for the UK property investment community. The paper is based on research commissioned by the Investment Property Forum (IPF) and funded through the IPF Research Programme (2006-2009). Design/methodology/approach – Interviews were undertaken with experts from the fields of property investment and building engineering. The interviews were undertaken with to identify: the current knowledge of EPCs in the property investment sector; key issues with practical implementation of the legislation; and perceptions of the potential impacts of legislation, particularly in relation to value stakeholder and behaviour. Findings – The paper finds that, although the regulations have been published, there is still a need for clarification in the marketplace with regard to some of the detail of regulations and the certification process. The following areas are of most concern to property investors: costs of surveys; potential difficulties with the process; and a shortage of assessors. With respect to these impacts it is becoming clear that investors who have not yet started considering the EPBD and its requirements within their strategy are likely to face difficulties in the short term. The most significant value-related impacts of EPBD are expected to be value differentiation of properties and “price chipping” against the rental or capital value of the property, where an occupier or potential purchaser will use the recommendations contained within an EPC to force a reduction in value. The latter is expected to emerge in the short term, whereas the former is expected to be realised over the medium to long term. Both these impacts have potentially significant implications for property investment holdings and also future investment behaviour.
Resumo:
Heating, ventilation, air conditioning and refrigeration (HVAC&R) systems account for more than 60% of the energy consumption of buildings in the UK. However, the effect of the variety of HVAC&R systems on building energy performance has not yet been taken into account within the existing building energy benchmarks. In addition, the existing building energy benchmarks are not able to assist decision-makers with HVAC&R system selection. This study attempts to overcome these two deficiencies through the performance characterisation of 36 HVAC&R systems based on the simultaneous dynamic simulation of a building and a variety of HVAC&R systems using TRNSYS software. To characterise the performance of HVAC&R systems, four criteria are considered; energy consumption, CO2 emissions, thermal comfort and indoor air quality. The results of the simulations show that, all the studied systems are able to provide an acceptable level of indoor air quality and thermal comfort. However, the energy consumption and amount of CO2 emissions vary. One of the significant outcomes of this study reveals that combined heating, cooling and power systems (CCHP) have the highest energy consumption with the lowest energy related CO2 emissions among the studied HVAC&R systems.
Resumo:
Existing buildings contribute greatly to global energy use and greenhouse gas emissions. In the UK, about 18% of carbon emissions are generated by non-domestic buildings; sustainable building refurbishment can play an important role in reducing carbon emissions. This paper looks at the performance of a recently refurbished 5-storey office building in London, in terms of energy consumption as well as occupants’ satisfaction. Pre- and post-occupancy evaluation studies were conducted using online questionnaire surveys and energy consumption evaluation. Results from pre-occupancy and post-occupancy evaluation studies showed that employees, in general, were more satisfied with their work environment at the refurbished building than with that of their previous office. Employees’ self-reported productivity improved after the move to Elms House. These surveys showed a positive relationship between employees’ satisfaction with their work environment and their self-reported productivity, well-being and enjoyment at work. The factor that contributed to increasing employee satisfaction the most was: better use of interior space. Although the refurbishment was a success in terms of reducing energy consumption per m2, the performance gap was almost 3 times greater than that estimated. Unregulated loads, problems with building control, ineffective use of space and occupants’ behaviour are argued to be reasons for this gap.
Resumo:
The purpose of the article is to describe and analyse Ghana’s AKOBEN programme which is the first environmental performance rating and public disclosure programme in Africa. Furthermore, by means of a SWOT analysis, the article assesses the suitability of AKOBEN as a veritable tool for promoting good environmental governance in Ghana specifically and Africa in general.
Resumo:
It is generally accepted that the physical workplace environment affects employees’ satisfaction and, consequently, their perceived productivity and well-being. This study investigated whether employee “satisfaction” variables can predict perceived productivity, well-being and enjoyment at work, and if so, to what extent. The study also explored whether limiting employees’ control over their environment could save energy without compromising employees’ satisfaction and perceived productivity. Preoccupancy and post-occupancy evaluation studies were conducted, in terms of both energy consumption and employee perceptions, to make comparisons between a company’s old and current headquarters buildings, both located in the same area of London. The results showed that employees were more satisfied with their work environment at their new HQ, in general, than with that of their previous office. Also, employees’ self-reported productivity, well-being and enjoyment at work improved after the move. It was revealed that the combination of employees’ level of satisfaction with “interior use of space” and “physical conditions” was the best predictor of their perceived productivity, while satisfaction with “indoor facilities” was not a good predictor. In terms of energy performance, although the new HQ’s energy consumption per m2 was significantly less than that of the previous building, there was still a gap between the refurbishment design target and the actual performance of the building. The findings suggest that this gap could be due to a number of factors, including an ineffective use of interior space, and occupants’ behaviour.
Resumo:
This paper deals with the energy consumption and the evaluation of the performance of air supply systems for a ventilated room involving high- and low-level supplies. The energy performance assessment is based on the airflow rate, which is related to the fan power consumption by achieving the same environmental quality performance for each case. Four different ventilation systems are considered: wall displacement ventilation, confluent jets ventilation, impinging jet ventilation and a high level mixing ventilation system. The ventilation performance of these systems will be examined by means of achieving the same Air Distribution Index (ADI) for different cases. The widely used high-level supplies require much more fan power than those for low-level supplies for achieving the same value of ADI. In addition, the supply velocity, hence the supply dynamic pressure, for a high-level supply is much larger than for low-level supplies. This further increases the power consumption for high-level supply systems. The paper considers these factors and attempts to provide some guidelines on the difference in the energy consumption associated with high and low level air supply systems. This will be useful information for designers and to the authors' knowledge there is a lack of information available in the literature on this area of room air distribution. The energy performance of the above-mentioned ventilation systems has been evaluated on the basis of the fan power consumed which is related to the airflow rate required to provide equivalent indoor environment. The Air Distribution Index (ADI) is used to evaluate the indoor environment produced in the room by the ventilation strategy being used. The results reveal that mixing ventilation requires the highest fan power and the confluent jets ventilation needs the lowest fan power in order to achieve nearly the same value of ADI.
Resumo:
This paper investigates whether energy performance ratings, as measured by mandatory Energy Performance Certificates (EPCs), are reflected in the sale prices of residential properties. This is the first large-scale empirical study of this topic in the UK involving approximately 400,000 dwellings in the period from 1995 to 2011. Applying hedonic regression and an augmented repeat sales regression, we find a positive relationship between the energy efficiency rating of a dwelling and the transaction price per square metre. The price effects of superior energy performance tend to be higher for terraced dwellings and flats compared to detached and semi-detached dwellings. The evidence is less clear-cut for house price growth rates but remains supportive of an overall positive association. Overall, the results of this study appear to support the hypothesis that energy efficiency levels are reflected in UK house prices, at least in recent years.
Resumo:
This paper investigates whether the intrinsic energy efficiency rating of an office building has a significant impact on its rental value. A sample of 817 transactions for offices with Energy Performance Certificates (EPCs) in the UK is used to assess whether a pricing differential can be identified, depending on the energy rating. While previous analyses of this topic have typically relied on appraisal-based and/or asking rent data, the dataset used in this research contains actual contract rents as well as information on lease terms. The results indicate a significant rental premium for energy-efficient buildings. However, it is found that this premium appears to be mainly driven by the youngest cohort of state-of-the-art energy-efficient buildings. The results also show that tenants of more energy-efficient buildings tend to pay a lower service charge, but this link appears to be rather weak and limited to newer buildings. Hence, it is argued that the information contained in the EPC is still not fully taken into account in the UK commercial property market with the possible exception of both the highest and the lowest EPC ratings.
Resumo:
This paper investigates whether energy performance ratings, as measured by mandatory Energy Performance Certificates (EPCs), are reflected in the sale prices of residential properties. This is the first large-scale empirical study of this topic in England involving 333,095 dwellings sold at least twice in the period from 1995 to 2012. Applying hedonic regression and an augmented repeat sales regression, we find a positive relationship between the energy efficiency rating of a dwelling and the transaction price per square metre. The price effects of superior energy performance tend to be higher for terraced dwellings and flats compared to detached and semi-detached dwellings. The evidence is less clear-cut for rates of house price growth but remains supportive of a positive association. Overall, the results of this study suggest that energy efficiency labels have a measurable and significant impact on house prices in England
Resumo:
In this paper we evaluate the performance of our earlier proposed enhanced relay-enabled distributed coordination function (ErDCF) for wireless ad hoc networks. The idea of ErDCF is to use high data rate nodes to work as relays for the low data rate nodes. ErDCF achieves higher throughput and reduced energy consumption compared to IEEE 802.11 distributed coordination function (DCF). This is a result of. 1) using relay which helps to increase the throughput and lower overall blocking time of nodes due to faster dual-hop transmission, 2) using dynamic preamble (i.e. using short preamble for the relay transmission) which further increases the throughput and lower overall blocking time and also by 3) reducing unnecessary overhearing (by other nodes not involved in transmission). We evaluate the throughput and energy performance of the ErDCF with different rate combinations. ErDCF (11,11) (ie. R1=R2=11 Mbps) yields a throughput improvement of 92.9% (at the packet length of 1000 bytes) and an energy saving of 72.2% at 50 nodes.