28 resultados para Energy in DPL

em CentAUR: Central Archive University of Reading - UK


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Of the technologies currently available for producing energy from renewable sources in the British climate all except one depend on a single ingredient, namely land. Therefore other than offshore wind generation, which has been slow and expensive to establish, renewables have had to be derived almost entirely from the land, whether as sites for turbines or areas on which to grow feedstocks for biomass and biofuels. Of these, only wind turbines have been developed in any number while economic conditions have until now been unfavourable for biomass and biofuel. The UK is unlikely to meet its present targets under the Kyoto agreement, due to a mixture of limited funding and problems of policy. Peter Prag examines the present position and the potential outlook.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As a vital factor affecting system cost and lifetime, energy consumption in wireless sensor networks (WSNs) has been paid much attention to. This article reviews existing energy harvesting technology applied in WSNs, and analyzes advantages of harvesting radio frequency (RF) energy in WSNs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The adiabatic transit time of wave energy radiated by an Agulhas ring released in the South Atlantic Ocean to the North Atlantic Ocean is investigated in a two-layer ocean model. Of particular interest is the arrival time of baroclinic energy in the northern part of the Atlantic, because it is related to variations in the meridional overturning circulation. The influence of the Mid-Atlantic Ridge is also studied, because it allows for the conversion from barotropic to baroclinic wave energy and the generation of topographic waves. Barotropic energy from the ring is present in the northern part of the model basin within 10 days. From that time, the barotropic energy keeps rising to attain a maximum 500 days after initiation. This is independent of the presence or absence of a ridge in the model basin. Without a ridge in the model, the travel time of the baroclinic signal is 1300 days. This time is similar to the transit time of the ring from the eastern to the western coast of the model basin. In the presence of the ridge, the baroclinic signal arrives in the northern part of the model basin after approximately 10 days, which is the same time scale as that of the barotropic signal. It is apparent that the ridge can facilitate the energy conversion from barotropic to baroclinic waves and the slow baroclinic adjustment can be bypassed. The meridional overturning circulation, parameterized in two ways as either a purely barotropic or a purely baroclinic phenomenon, also responds after 1300 days. The ring temporarily increases the overturning strength. Th presence of the ridge does not alter the time scales.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trends in China's energy future will have considerable consequences for both China and the global environment. Though China's carbon emissions are low on a per capita basis, China is already ranked the world's second largest producer of carbon, behind only America. China's buildings sector currently accounts for 23% of China's total energy use and is projected to increase to one-third by 2010. Energy policy plays an important role in China's sustainable development. The purpose of this study is to provide a broad overview of energy efficiency issues in the built environment in China. This paper, firstly briefly, reviews the key national policies related to the built environment and demonstrates the government's environmental concern. Secondly, the authors introduce recent energy policies in the built environment. Energy efficiency and renewable energy in the built environment, which are the key issues of the national energy policy, have been reviewed. Discussion of the implementation of energy policy has been carried out.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is often assumed on the basis of single-parcel energetics that compressible effects and conversions with internal energy are negligible whenever typical displacements of fluid parcels are small relative to the scale height of the fluid (defined as the ratio of the squared speed of sound over gravitational acceleration). This paper shows that the above approach is flawed, however, and that a correct assessment of compressible effects and internal energy conversions requires considering the energetics of at least two parcels, or more generally, of mass conserving parcel re-arrangements. As a consequence, it is shown that it is the adiabatic lapse rate and its derivative with respect to pressure, rather than the scale height, which controls the relative importance of compressible effects and internal energy conversions when considering the global energy budget of a stratied fluid. Only when mass conservation is properly accounted for is it possible to explain why available internal energy can account for up to 40 percent of the total available potential energy in the oceans. This is considerably larger than the prediction of single-parcel energetics, according to which this number should be no more than about 2 percent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We use the elliptic reconstruction technique in combination with a duality approach to prove a posteriori error estimates for fully discrete backward Euler scheme for linear parabolic equations. As an application, we combine our result with the residual based estimators from the a posteriori estimation for elliptic problems to derive space-error indicators and thus a fully practical version of the estimators bounding the error in the $ \mathrm {L}_{\infty }(0,T;\mathrm {L}_2(\varOmega ))$ norm. These estimators, which are of optimal order, extend those introduced by Eriksson and Johnson in 1991 by taking into account the error induced by the mesh changes and allowing for a more flexible use of the elliptic estimators. For comparison with previous results we derive also an energy-based a posteriori estimate for the $ \mathrm {L}_{\infty }(0,T;\mathrm {L}_2(\varOmega ))$-error which simplifies a previous one given by Lakkis and Makridakis in 2006. We then compare both estimators (duality vs. energy) in practical situations and draw conclusions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In domain of intelligent buildings, saving energy in buildings and increasing preferences of occupants are two important factors. These factors are the important keys for evaluating the performance of work environment. In recent years, many researchers combine these areas to create the system that can change from original to the modern work environment called intelligent work environment. Due to advance of agent technology, it has received increasing attention in the area of intelligent pervasive environments. In this paper, we review several issues in intelligent buildings, with respect to the implementation of control system for intelligent buildings via multi-agent systems. Furthermore, we present the MASBO (Multi-Agent System for Building cOntrol) that has been implemented for controlling the building facilities to reach the balancing between energy efficiency and occupant’s comfort. In addition to enhance the MASBO system, the collaboration through negotiation among agents is presented.

Relevância:

90.00% 90.00%

Publicador:

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A physiological experiment was carried out in a naturally ventilated, non-HVAC indoor environment of a spacious experimental room. More than 300 healthy university students volunteered for this study. The purpose of the study was to investigate the human physiological indicators which could be used to characterise the indoor operative temperature changes in a building and their impact on human thermal comfort based on the different climatic characteristics people would experience in Chongqing, China. The study found that sensory nerve conduction velocity (SCV) could objectively provide a good indicator for assessment of the human response to changes in indoor operative temperatures in a naturally ventilated situation. The results showed that with the changes in the indoor operative temperatures, the changing trend in the nerve conduction velocity was basically the same as that of the skin temperature at the sensory nerve measuring segment (Tskin(scv)). There was good coherent consistency among the factors: indoor operative temperature, SCV and Tskin(scv) in a certain indoor operative temperature range. Through self-adaptation and self-feedback regulation, the human physiological indicators would produce certain adaptive changes to deal with the changes in indoor operative temperature. The findings of this study should provide the baseline data to inform guidelines for the development of thermal environment-related standards that could contribute to efficient use of energy in buildings in China.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Global climate change results from a small yet persistent imbalance between the amount of sunlight absorbed by Earth and the thermal radiation emitted back to space. An apparent inconsistency has been diagnosed between interannual variations in the net radiation imbalance inferred from satellite measurements and upper-ocean heating rate from in situ measurements, and this inconsistency has been interpreted as ‘missing energyin the system. Here we present a revised analysis of net radiation at the top of the atmosphere from satellite data, and we estimate ocean heat content, based on three independent sources. We find that the difference between the heat balance at the top of the atmosphere and upper-ocean heat content change is not statistically significant when accounting for observational uncertainties in ocean measurements, given transitions in instrumentation and sampling. Furthermore, variability in Earth’s energy imbalance relating to El Niño-Southern Oscillation is found to be consistent within observational uncertainties among the satellite measurements, a reanalysis model simulation and one of the ocean heat content records. We combine satellite data with ocean measurements to depths of 1,800 m, and show that between January 2001 and December 2010, Earth has been steadily accumulating energy at a rate of 0.50±0.43 Wm−2 (uncertainties at the 90% confidence level). We conclude that energy storage is continuing to increase in the sub-surface ocean.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Occupants’ behaviour when improving the indoor environment plays a significant role in saving energy in buildings. Therefore the key step to reducing energy consumption and carbon emissions from buildings is to understand how occupants interact with the environment they are exposed to in terms of achieving thermal comfort and well-being; though such interaction is complex. This paper presents a dynamic process of occupant behaviours involving technological, personal and psychological adaptations in response to varied thermal conditions based on the data covering four seasons gathered from the field study in Chongqing, China. It demonstrates that occupants are active players in environmental control and their adaptive responses are driven strongly by ambient thermal stimuli and vary from season to season and from time to time, even on the same day. Positive, dynamic, behavioural adaptation will help save energy used in heating and cooling buildings. However, when environmental parameters cannot fully satisfy occupants’ requirements, negative behaviours could conflict with energy saving. The survey revealed that about 23% of windows are partly open for fresh air when air-conditioners are in operation in summer. This paper addresses the issues how the building and environmental systems should be designed, operated and managed in a way that meets the requirements of energy efficiency without compromising wellbeing and productivity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper arises from a doctoral thesis comparing the impact of alternative installer business models on the rate at which microgeneration is taken up in homes and installation standards across the UK. The paper presents the results of the first large-scale academic survey of businesses certified to install residential microgeneration. The aim is to systematically capture those characteristics which define the business model of each surveyed company, and relate these to the number, location and type of technologies that they install, and the quality of these installations. The methodology comprised a pilot web survey of 235 certified installer businesses, which was carried out in June last year and achieved a response rate of 30%. Following optimisation of the design, the main web survey was emailed to over 2000 businesses between October and December 2011, with 317 valid responses received. The survey is being complemented during summer 2012 by semi-structured interviews with a representative sample of installers who completed the main survey. The survey results are currently being analysed. The early results indicate an emerging and volatile market where solar PV, solar hot water and air source heat pumps are the dominant technologies. Three quarters of respondents are founders of their installer business, while only 22 businesses are owned by another company. Over half of the 317 businesses have five employees or less, while 166 businesses are no more than four years old. In addition, half of the businesses stated that 100% of their employees work on microgeneration-related activities. 85% of the surveyed companies have only one business location in the UK. A third of the businesses are based either in the South West or South East regions of England. This paper outlines the interim results of the survey combined with the outcomes from additional interviews with installers to date. The research identifies some of the business models underpinning microgeneration installers and some of the ways in which installer business models impact on the rate and standards of microgeneration uptake. A tentative conclusion is that installer business models are profoundly dependent on the levels and timing of support from the UK Feed-in Tariffs and Renewable Heat Incentive.