24 resultados para Emergency medical system
em CentAUR: Central Archive University of Reading - UK
Resumo:
Stroke is a medical emergency and can cause a neurological damage, affecting the motor and sensory systems. Harnessing brain plasticity should make it possible to reconstruct the closed loop between the brain and the body, i.e., association of the generation of the motor command with the somatic sensory feedback might enhance motor recovery. In order to aid reconstruction of this loop with a robotic device it is necessary to assist the paretic side of the body at the right moment to achieve simultaneity between motor command and feedback signal to somatic sensory area in brain. To this end, we propose an integrated EEG-driven assistive robotic system for stroke rehabilitation. Depending on the level of motor recovery, it is important to provide adequate stimulation for upper limb motion. Thus, we propose an assist arm incorporating a Magnetic Levitation Joint that can generate a compliant motion due to its levitation and mechanical redundancy. This paper reports on a feasibility study carried out to verify the validity of the robot sensing and on EEG measurements conducted with healthy volunteers while performing a spontaneous arm flexion/extension movement. A characteristic feature was found in the temporal evolution of EEG signal in the single motion prior to executed motion which can aid in coordinating timing of the robotic arm assistance onset.
Resumo:
Accident and Emergency (A&E) units provide a route for patients requiring urgent admission to acute hospitals. Public concern over long waiting times for admissions motivated this study, whose aim is to explore the factors which contribute to such delays. The paper discusses the formulation and calibration of a system dynamics model of the interaction of demand pattern, A&E resource deployment, other hospital processes and bed numbers; and the outputs of policy analysis runs of the model which vary a number of the key parameters. Two significant findings have policy implications. One is that while some delays to patients are unavoidable, reductions can be achieved by selective augmentation of resources within, and relating to, the A&E unit. The second is that reductions in bed numbers do not increase waiting times for emergency admissions, their effect instead being to increase sharply the number of cancellations of admissions for elective surgery. This suggests that basing A&E policy solely on any single criterion will merely succeed in transferring the effects of a resource deficit to a different patient group.
Resumo:
Objectives: To assess the impact of a closed-loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Design, setting and participants: Before-and-after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Intervention: Closed-loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Main outcome measures: Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Results: Prescribing errors were identified in 3.8% of 2450 medication orders pre-intervention and 2.0% of 2353 orders afterwards (p<0.001; χ2 test). MAEs occurred in 7.0% of 1473 non-intravenous doses pre-intervention and 4.3% of 1139 afterwards (p = 0.005; χ2 test). Patient identity was not checked for 82.6% of 1344 doses pre-intervention and 18.9% of 1291 afterwards (p<0.001; χ2 test). Medical staff required 15 s to prescribe a regular inpatient drug pre-intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre-intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; χ2 test). Conclusions: A closed-loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication-related tasks increased.
Resumo:
Objective To assess the impact of a closed-loop electronic prescribing and automated dispensing system on the time spent providing a ward pharmacy service and the activities carried out. Setting Surgical ward, London teaching hospital. Method All data were collected two months pre- and one year post-intervention. First, the ward pharmacist recorded the time taken each day for four weeks. Second, an observational study was conducted over 10 weekdays, using two-dimensional work sampling, to identify the ward pharmacist's activities. Finally, medication orders were examined to identify pharmacists' endorsements that should have been, and were actually, made. Key findings Mean time to provide a weekday ward pharmacy service increased from 1 h 8 min to 1 h 38 min per day (P = 0.001; unpaired t-test). There were significant increases in time spent prescription monitoring, recommending changes in therapy/monitoring, giving advice or information, and non-productive time. There were decreases for supply, looking for charts and checking patients' own drugs. There was an increase in the amount of time spent with medical and pharmacy staff, and with 'self'. Seventy-eight per cent of patients' medication records could be assessed for endorsements pre- and 100% post-intervention. Endorsements were required for 390 (50%) of 787 medication orders pre-intervention and 190 (21%) of 897 afterwards (P < 0.0001; chi-square test). Endorsements were made for 214 (55%) of endorsement opportunities pre-intervention and 57 (30%) afterwards (P < 0.0001; chi-square test). Conclusion The intervention increased the overall time required to provide a ward pharmacy service and changed the types of activity undertaken. Contact time with medical and pharmacy staff increased. There was no significant change in time spent with patients. Fewer pharmacy endorsements were required post-intervention, but a lower percentage were actually made. The findings have important implications for the design, introduction and use of similar systems.
Resumo:
Virtual Reality (VR) is widely used in visualizing medical datasets. This interest has emerged due to the usefulness of its techniques and features. Such features include immersion, collaboration, and interactivity. In a medical visualization context, immersion is important, because it allows users to interact directly and closelywith detailed structures in medical datasets. Collaboration on the other hand is beneficial, because it gives medical practitioners the chance to share their expertise and offer feedback and advice in a more effective and intuitive approach. Interactivity is crucial in medical visualization and simulation systems, because responsiveand instantaneous actions are key attributes in applications, such as surgical simulations. In this paper we present a case study that investigates the use of VR in a collaborative networked CAVE environment from a medical volumetric visualization perspective. The study will present a networked CAVE application, which has been built to visualize and interact with volumetric datasets. We will summarize the advantages of such an application and the potential benefits of our system. We also will describe the aspects related to this application area and the relevant issues of such implementations.
Resumo:
Sirens used by police, fire and paramedic vehicles have been designed so that they can be heard over large distances, but unfortunately the siren noise enters the vehicle and corrupts intelligibility of voice communications from the emergency vehicle to the control room. Often the siren needs to be turned off to enable the control room to hear what is being said. This paper discusses a siren noise filter system that is capable of removing the siren noise picked up by the two-way radio microphone inside the vehicle. The removal of the siren noise improves the response time for emergency vehicles and thus save lives. To date, the system has been trialed within a fire tender in a non-emergency situation, with good results.
Resumo:
The development of an adaptive filter system, capable of reducing significantly the effect of siren noise within the cab of an emergency vehicle, is described. The system is capable of removing the siren noise picked up by the radio microphone inside the vehicle, without degrading the wanted voice signal, thus allowing the siren to be used at all times.
Resumo:
Emergency vehicles use high-amplitude sirens to warn pedestrians and other road users of their presence. Unfortunately, the siren noise enters the vehicle and corrupts the intelligibility of two-way radio voice com-munications from the emergency vehicle to a control room. Often the siren has to be turned off to enable the control room to hear what is being said which subsequently endangers people's lives. A digital signal processing (DSP) based system for the cancellation of siren noise embedded within speech is presented. The system has been tested with the least mean square (LMS), normalised least mean square (NLMS) and affine projection algorithm (APA) using recordings from three common types of sirens (two-tone, wail and yelp) from actual test vehicles. It was found that the APA with a projection order of 2 gives comparably improved cancellation over the LMS and NLMS with only a moderate increase in algorithm complexity and code size. Therefore, this siren noise cancellation system using the APA offers an improvement in cancellation achieved by previous systems. The removal of the siren noise improves the response time for the emergency vehicle and thus the system can contribute to saving lives. The system also allows voice communication to take place even when the siren is on and as such the vehicle offers less risk of danger when moving at high speeds in heavy traffic.
Resumo:
Sirens’ used by police, fire and paramedic vehicles generate noise that propagates inside the vehicle cab that subsequently corrupts intelligibility of voice communications from the emergency vehicle to the control room. It is even common for the siren to be turned off to enable the control room to hear what is being said. Both fixed filter and adaptive filter systems have previously been developed to help cancel the transmission of the siren noise over the radio. Previous cancellation systems have only concentrated on the traditional 2-tone, wail and yelp sirens. This paper discusses an improvement to a previous adaptive filter system and presents the cancellation results to three new types of sirens; being chirp pulsar and localiser. A siren noise filter system has the capability to improve the response time for an emergency vehicle and thus help save lives. To date, this system has been tested using live recordings taken from a nonemergency situation with good results.
Resumo:
The Nyasaland Emergency in 1959 proved a decisive turning point in the history of the Federation of Rhodesia and Nyasaland, which from 1953 to 1963 brought together the territories of Northern Rhodesia (Zambia), Southern Rhodesia (Zambia) and Nyasaland (Malawi) under a settler-dominated federal government. The British and Nyasaland governments defended the emergency by claiming to have gathered intelligence which showed that the Nyasaland African Congress was preparing a campaign of sabotage and murder. The Devlin Commission, appointed to investigate the emergency, dismissed the evidence of a ‘murder plot’, criticised the Nyasaland government's handling of the Emergency and, notoriously, described Nyasaland as a ‘police state’. This article has two principal aims. First, using the recently declassified papers of the Intelligence and Security Department (ISD) of the Colonial Office, it seeks to provide the first detailed account of what the British government knew of the intelligence relating to the ‘murder plot’ and how they assessed it, prior to the outbreak of the emergency. It demonstrates that officials in the ISD and members of the Security Service adopted a far more cautious attitude towards the intelligence than did Conservative ministers, and had greater qualms about allowing it into the public domain to justify government policy. Second, the article examines the implications of Devlin's use of the phrase ‘police state’ for Nyasaland and for the late colonial state in general. It contrasts Devlin's use of the term with that of security experts in the ISD, who routinely applied it to policing systems that diverged from their own preferred model. Hence, whereas Devlin compared policing in Nyasaland unfavourably with that in Southern Rhodesia, implying, ironically, that Nyasaland was ‘under-policed’ (because there were fewer police per head of population in Nyasaland than in Southern Rhodesia), the ISD regarded the intensive system of policing operated by the British South Africa Police in Southern Rhodesia as characteristic of a ‘police state’. The article suggests that the frequent use of the term ‘police state’ was indicative of broader anxieties about what Britain's legacy would be for the post-independence African state.