44 resultados para Electronic Structured
em CentAUR: Central Archive University of Reading - UK
Resumo:
Point defects in metal oxides such as TiO2 are key to their applications in numerous technologies. The investigation of thermally induced nonstoichiometry in TiO2 is complicated by the difficulties in preparing and determining a desired degree of nonstoichiometry. We study controlled self-doping of TiO2 by adsorption of 1/8 and 1/16 monolayer Ti at the (110) surface using a combination of experimental and computational approaches to unravel the details of the adsorption process and the oxidation state of Ti. Upon adsorption of Ti, x-ray and ultraviolet photoemission spectroscopy (XPS and UPS) show formation of reduced Ti. Comparison of pure density functional theory (DFT) with experiment shows that pure DFT provides an inconsistent description of the electronic structure. To surmount this difficulty, we apply DFT corrected for on-site Coulomb interaction (DFT+U) to describe reduced Ti ions. The optimal value of U is 3 eV, determined from comparison of the computed Ti 3d electronic density of states with the UPS data. DFT+U and UPS show the appearance of a Ti 3d adsorbate-induced state at 1.3 eV above the valence band and 1.0 eV below the conduction band. The computations show that the adsorbed Ti atom is oxidized to Ti2+ and a fivefold coordinated surface Ti atom is reduced to Ti3+, while the remaining electron is distributed among other surface Ti atoms. The UPS data are best fitted with reduced Ti2+ and Ti3+ ions. These results demonstrate that the complexity of doped metal oxides is best understood with a combination of experiment and appropriate computations.
Resumo:
Alternative meshes of the sphere and adaptive mesh refinement could be immensely beneficial for weather and climate forecasts, but it is not clear how mesh refinement should be achieved. A finite-volume model that solves the shallow-water equations on any mesh of the surface of the sphere is presented. The accuracy and cost effectiveness of four quasi-uniform meshes of the sphere are compared: a cubed sphere, reduced latitude–longitude, hexagonal–icosahedral, and triangular–icosahedral. On some standard shallow-water tests, the hexagonal–icosahedral mesh performs best and the reduced latitude–longitude mesh performs well only when the flow is aligned with the mesh. The inclusion of a refined mesh over a disc-shaped region is achieved using either gradual Delaunay, gradual Voronoi, or abrupt 2:1 block-structured refinement. These refined regions can actually degrade global accuracy, presumably because of changes in wave dispersion where the mesh is highly nonuniform. However, using gradual refinement to resolve a mountain in an otherwise coarse mesh can improve accuracy for the same cost. The model prognostic variables are height and momentum collocated at cell centers, and (to remove grid-scale oscillations of the A grid) the mass flux between cells is advanced from the old momentum using the momentum equation. Quadratic and upwind biased cubic differencing methods are used as explicit corrections to a fast implicit solution that uses linear differencing.
Resumo:
We present the first observational evidence of the near-Sun distortion of the leading edge of a coronal mass ejection (CME) by the ambient solar wind into a concave structure. On 2007 November 14, a CME was observed by coronagraphs onboard the STEREO-B spacecraft, possessing a circular cross section. Subsequently the CME passed through the field of view of the STEREO-B Heliospheric Imagers where the leading edge was observed to distort into an increasingly concave structure. The CME observations are compared to an analytical flux rope model constrained by a magnetohydrodynamic solar wind solution. The resultant bimodal speed profile is used to kinematically distort a circular structure that replicates the initial shape of the CME. The CME morphology is found to change rapidly over a relatively short distance. This indicates an approximate radial distance in the heliosphere where the solar wind forces begin to dominate over the magnetic forces of the CME influencing the shape of the CME.
Resumo:
Numerical simulations of magnetic clouds (MCs) propagating through a structured solar wind suggest that MC-associated magnetic flux ropes are highly distorted by inhomogeneities in the ambient medium. In particular, a solar wind configuration of fast wind from high latitudes and slow wind at low latitudes, common at periods close to solar minimum, should distort the cross section of magnetic clouds into concave-outward structures. This phenomenon has been reported in observations of shock front orientations, but not in the body of magnetic clouds. In this study an analytical magnetic cloud model based upon a kinematically distorted flux rope is modified to simulate propagation through a structured medium. This new model is then used to identify specific time series signatures of the resulting concave-outward flux ropes. In situ observations of three well studied magnetic clouds are examined with comparison to the model, but the expected concave-outward signatures are not present. Indeed, the observations are better described by the convex-outward flux rope model. This may be due to a sharp latitudinal transition from fast to slow wind, resulting in a globally concave-outward flux rope, but with convex-outward signatures on a local scale.
Resumo:
Aims To investigate the effects of electronic prescribing (EP) on prescribing quality, as indicated by prescribing errors and pharmacists' clinical interventions, in a UK hospital. Methods Prescribing errors and pharmacists' interventions were recorded by the ward pharmacist during a 4 week period both pre- and post-EP, with a second check by the principal investigator. The percentage of new medication orders with a prescribing error and/or pharmacist's intervention was calculated for each study period. Results Following the introduction of EP, there was a significant reduction in both pharmacists' interventions and prescribing errors. Interventions reduced from 73 (3.0% of all medication orders) to 45 (1.9%) (95% confidence interval (CI) for the absolute reduction 0.2, 2.0%), and errors from 94 (3.8%) to 48 (2.0%) (95% CI 0.9, 2.7%). Ten EP-specific prescribing errors were identified. Only 52% of pharmacists' interventions related to a prescribing error pre-EP, and 60% post-EP; only 40% and 56% of prescribing errors resulted in an intervention pre- and post-EP, respectively. Conclusions EP improved the quality of prescribing by reducing both prescribing errors and pharmacists' clinical interventions. Prescribers and pharmacists need to be aware of new types of error with EP, so that they can best target their activities to reduce clinical risk. Pharmacists may need to change the way they work to complement, rather than duplicate, the benefits of EP.
Resumo:
Objectives: To assess the impact of a closed-loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Design, setting and participants: Before-and-after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Intervention: Closed-loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Main outcome measures: Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Results: Prescribing errors were identified in 3.8% of 2450 medication orders pre-intervention and 2.0% of 2353 orders afterwards (p<0.001; χ2 test). MAEs occurred in 7.0% of 1473 non-intravenous doses pre-intervention and 4.3% of 1139 afterwards (p = 0.005; χ2 test). Patient identity was not checked for 82.6% of 1344 doses pre-intervention and 18.9% of 1291 afterwards (p<0.001; χ2 test). Medical staff required 15 s to prescribe a regular inpatient drug pre-intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre-intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; χ2 test). Conclusions: A closed-loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication-related tasks increased.
Resumo:
Objective To assess the impact of a closed-loop electronic prescribing and automated dispensing system on the time spent providing a ward pharmacy service and the activities carried out. Setting Surgical ward, London teaching hospital. Method All data were collected two months pre- and one year post-intervention. First, the ward pharmacist recorded the time taken each day for four weeks. Second, an observational study was conducted over 10 weekdays, using two-dimensional work sampling, to identify the ward pharmacist's activities. Finally, medication orders were examined to identify pharmacists' endorsements that should have been, and were actually, made. Key findings Mean time to provide a weekday ward pharmacy service increased from 1 h 8 min to 1 h 38 min per day (P = 0.001; unpaired t-test). There were significant increases in time spent prescription monitoring, recommending changes in therapy/monitoring, giving advice or information, and non-productive time. There were decreases for supply, looking for charts and checking patients' own drugs. There was an increase in the amount of time spent with medical and pharmacy staff, and with 'self'. Seventy-eight per cent of patients' medication records could be assessed for endorsements pre- and 100% post-intervention. Endorsements were required for 390 (50%) of 787 medication orders pre-intervention and 190 (21%) of 897 afterwards (P < 0.0001; chi-square test). Endorsements were made for 214 (55%) of endorsement opportunities pre-intervention and 57 (30%) afterwards (P < 0.0001; chi-square test). Conclusion The intervention increased the overall time required to provide a ward pharmacy service and changed the types of activity undertaken. Contact time with medical and pharmacy staff increased. There was no significant change in time spent with patients. Fewer pharmacy endorsements were required post-intervention, but a lower percentage were actually made. The findings have important implications for the design, introduction and use of similar systems.
Resumo:
We describe the main features of a program written to perform electronic marking of quantitative or simple text questions. One of the main benefits is that it can check answers for being consistent with earlier errors, so can cope with a range of numerical questions. We summarise our experience of using it in a statistics course taught to 200 bioscience students.
Neat but not gaudy: planning and creating an electronic induction tutorial at the University of Bath
Resumo:
This paper describes a case study of an electronic data management system developed in-house by the Facilities Management Directorate (FMD) of an educational institution in the UK. The FMD Maintenance and Business Services department is responsible for the maintenance of the built-estate owned by the university. The department needs to have a clear definition of the type of work undertaken and the administration that enables any maintenance work to be carried out. These include the management of resources, budget, cash flow and workflow of reactive, preventative and planned maintenance of the campus. In order to be more efficient in supporting the business process, the FMD had decided to move from a paper-based information system to an electronic system, WREN, to support the business process of the FMD. Some of the main advantages of WREN are that it is tailor-made to fit the purpose of the users; it is cost effective when it comes to modifications on the system; and the database can also be used as a knowledge management tool. There is a trade-off; as WREN is tailored to the specific requirements of the FMD, it may not be easy to implement within a different institution without extensive modifications. However, WREN is successful in not only allowing the FMD to carry out the tasks of maintaining and looking after the built-estate of the university, but also has achieved its aim to minimise costs and maximise efficiency.
Resumo:
The triatomic spin-rovibronic variational code RVIB3 has been extended to include the effect of two uncoupled electrons, for both (3)Sigma(-) and (3)Pi (Renner-Teller) electronic states. The spin-orbital-rotational kinetic energy is included in the usual way, via terms (J+L+S). The phenomenological terms AL.S and lambda 2/3(3S(z)(2)) are introduced to reproduce the 3 spin-orbit and spin-spin splittings, respectively. Calculations are performed to evaluate the spin-rovibronic energy levels of CCO (X) over tilde (3) Sigma(-) and CCO (A) over tilde (3) Pi for which the Born-Oppenheimer potentials are derived from high-accuracy ab initio calculations.
Resumo:
The vibrational energy levels of diazocarbene (diazomethylene) in its electronic ground state, (X) over tilde (3) Sigma(-) CNN, have been predicted using the variational method. The potential energy surfaces of (X) over tilde (3) A" CNN were determined by employing ab initio single reference coupled cluster with single and double excitations (CCSD), CCSD with perturbative triple excitations [CCSD(T)], multi-reference complete active space self-consistent-field (CASSCF), and internally contracted multi-reference configuration interaction (ICMRCI) methods. The correlation-consistent polarised valence quadruple zeta (cc-pVQZ) basis set was used. Four sets of vibrational energy levels determined from the four distinct analytical potential functions have been compared with the experimental values from the laser-induced fluorescence measurements of Wurfel et al. obtained in 1992. The CCSD, CCSD(T), and CASSCF potentials have not provided satisfactory agreement with the experimental observations. In this light, the importance of both non-dynamic (static) and dynamic correlation effects in describing the ground state of CNN is emphasised. Our best theoretical fundamental frequencies at the cc-pVQZ ICMRCI level of theory, v(1) = 1230, v(2) = 394, and v(3) = 1420 cm(-1) are in excellent agreement with the experimental values of v(1) = 1235, v(2) = 396, and v(3) = 1419cm(-1) and the mean absolute deviation between the 23 calculated and experimental vibrational energy levels is only 7.4 cm(-1). It is shown that the previously suggested observation of the v(3) frequency at about 2847cm(-1) was in fact the first overtone 2v(3).
Resumo:
First-principles calculations of absolute line intensities and rovibrational energies of ozone (O-16(3)) are reported using potential energy and electric dipole moment functions calculated by the internally contracted MRCI approach. The rovibrational energies and eigenfunctions (up to about 8500 cm(-1) and J = 64) were obtained variationally with an exact Hamiltonian in internal valence coordinates. More than 4.8 x 10(6) electric dipole transition matrix elements were calculated for the absolute rovibrational line intensities. They are compared with the values of the HITRAN database. The purely rotational absolute line intensities in the (000) state and the rovibrational intensities for the (001)-(000) band agree to within about 0.3 to 1% for the (0 10)-(000) band to within about 3 to 4%. Excellent agreement with experiment is also achieved for low-lying overtone and combination bands. Inconsistencies are found for the (100)-(000) band overlapping with the antisymmetric stretching fundamental and also for the (002)-(000) antisymmetric stretching overtone. The generated dipole moment function can be used for predicting the absorption intensities in any of the heavier isotopomers, hot bands or the rates of spontaneous emission.