18 resultados para Driver Performance Testing.
em CentAUR: Central Archive University of Reading - UK
Resumo:
A wind catcher/tower natural ventilation system was installed in a seminar room in the building of the School of Construction Management and Engineering, the University of Reading in the UK . Performance was analysed by means of ventilation tracer gas measurements, indoor climate measurements (temperature, humidity, CO2) and occupant surveys. In addition, the potential of simple design tools was evaluated by comparing observed ventilation results with those predicted by an explicit ventilation model and the AIDA implicit ventilation model. To support this analysis, external climate parameters (wind speed and direction, solar radiation, external temperature and humidity) were also monitored. The results showed the chosen ventilation design provided a substantially greater ventilation rate than an equivalent area of openable window. Also air quality parameters stayed within accepted norms while occupants expressed general satisfaction with the system and with comfort conditions. Night cooling was maximised by using the system in combination with openable windows. Comparisons of calculations with ventilation rate measurements showed that while AIDA gave reasonably correlated results with the monitored performance results, the widely used industry explicit model was found to over estimate the monitored ventilation rate.
Resumo:
We discuss the utility of single nucleotide polymorphism loci for full trio and mother-unavailable paternity testing cases, in the presence of population substructure and relatedness of putative and actual fathers. We focus primarily on the expected number of loci required to gain specified probabilities of mismatches, and report the expected proportion of paternity indices greater than three threshold values for these loci. (c) 2004 Elsevier Ireland Ltd. All rights reserved.
Resumo:
This series of experiments investigated the role of a prefrontal cortical-dorsal striatal circuit in attention, using a continuous performance task of sustained and spatially divided visual attention. A unilateral excitotoxic lesion of the medial prefrontal cortex and a contralateral lesion of the medial caudate-putamen were used to "disconnect" the circuit. Control groups of rats with unilateral lesions of either structure were tested in the same task. Behavioral controls included testing the effects of the disconnection lesion on Pavlovian discriminated approach behavior. The disconnection lesion produced a significant reduction in the accuracy of performance in the attentional task but did not impair Pavlovian approach behavior or affect locomotor or motivational variables, providing evidence for the involvement of this medial prefrontal corticostriatal system in aspects of visual attentional function.
Resumo:
In this study, we assessed the influence of prey quality and prey biomass during a standardized 3-week test on adult survival and reproductive output of the predatory mite Hypoaspis aculeifer when fed one of six different diets: springtails (Folsomia candida and Folsomia fimetaria), a storage mite (Caloglyphus cf. michaeli), an oligochaete (Enchytraeus crypticus), a nematode (Turbatrix silusiae), and a 1:1:1 mix of F. candida:F.fimetaria:E. crypticus. Our results revealed that a single prey species may be nutritionally sufficient for a 3-week period, as H. aculeifer performed equally well, or better, on a diet based on a 1:1:1 mix of F. candida:F. fimetaria:E. crypticus. However, when fed C. cf. michaeli, H. aculeifer had a poor reproductive output (< 200 juveniles) and a reduced survival (60-70%). Thus, investigators should validate their choice of prey prior to testing H. aculeifer performance during toxicant exposure. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Experimental wind tunnel and smoke visualisation testing and CFD modelling were conducted to investigate the effect of air flow control mechanism and heat source inside rooms on wind catchers/towers performance. For this purpose, a full-scale wind catcher was connected to a test room and positioned centrally in an open boundary wind tunnel. Pressure coefficients (C-p's) around the wind catcher and air flow into the test room were established. The performance of the wind catcher depends greatly on the wind speed and direction. The incorporation of dampers and egg crate grille at ceiling level reduces and regulates the air flow rate with an average pressure loss coefficient of 0.01. The operation of the wind catcher in the presence of heat sources will potentially lower the internal temperatures in line with the external temperatures.
Resumo:
This paper presents the results of performance monitoring under real winter weather conditions, controlled laboratory testing and computational fluid dynamics (CFD) analysis of a wall mounted ventilation air inlet heat convector. For real winter weather monitoring, the wall-mounted convector was installed in a laboratory room of the Engineering Building of the School of Construction Management and Engineering. Air and hot water temperatures and air speeds were measured at the entrance to the convector and in the room. The hot water temperature was controlled at 40, 60 and 80 °C. The monitoring results were later used as boundary conditions for a CFD simulation to investigate the air movement in the room. Controlled laboratory testing was conducted in laboratories at the University of Reading, UK and at Wetterstad Consultancy, Sweden. The results of the performance investigation showed that the system contributed greatly to the room heating, particularly at a water temperature of 80 °C. Also adequate fresh air was supplied to the room. Such a system is able to provide an energy efficient method of eliminating problems associated with cold winter draughts.
Resumo:
Traits used by bacteria to enhance ecological performance in natural environments are not well understood. Recognizing that the saprophytic plant-colonizing bacterium Pseudomonas fluorescens SBW25 experiences temperatures in its natural environment significantly cooler than the 28°C routinely used in the laboratory, we identified proteins differentially expressed between 28°C and the more environmentally relevant temperature of 14°C. Of 2102 protein isoforms, 32 were temperature responsive and identified by mass spectrometry. Seven of these (OmpR, MucD, GuaD, OsmY and three of unknown function, Tee1, Tee2 and Tee3) were selected for genetic and ecological analyses. In each instance, changes in protein expression with temperature were mirrored by parallel transcriptional changes. The fitness contribution of the genes encoding each of the seven proteins was larger at 14°C than 28°C and included two cases of trade-offs (enhanced fitness at one temperature and reduced fitness at the other – mucD and tee2 deletions). The relationship between the fitness effects of genes in vitro and in vivo was variable, but two temperature-responsive genes – osmY and mucD – contribute substantially to the ability of P. fluorescens to colonize the plant environment.
Resumo:
The High Resolution Dynamics Limb Sounder is described, with particular reference to the atmospheric measurements to be made and the rationale behind the measurement strategy. The demands this strategy places on the filters to be used in the instrument and the designs to which this leads to are described. A second set of filters at an intermediate image plane to reduce "Ghost Imaging" is discussed together with their required spectral properties. A method of combining the spectral characteristics of the primary and secondary filters in each channel are combined together with the spectral response of the detectors and other optical elements to obtain the system spectral response weighted appropriately for the Planck function and atmospheric limb absorption. This method is used to demonstrate whether the out-of-band spectral blocking requirement for a channel is being met and an example calculation is demonstrated showing how the blocking is built up for a representative channel. Finally, the techniques used to produce filters of the necessary sub-millimetre sizes together with the testing methods and procedures used to assess the environmental durability and establish space flight quality are discussed.
Resumo:
With no universal approach for measuring brand performance, we show how a consumer-based brand measure was developed for corporate financial services brands. Churchill's paradigm was adopted. A literature review and 20 depth interviews with experts suggested that brand loyalty, consumer satisfaction and reputation constitute the brand performance measure. Ten financial services organisations provided access to their consumers. Following a postal survey, 600 questionnaires were analysed through principal components analysis to identify the consumer-based measure. Further testing revealed this to be a valid and reliable brand performance measure.
Resumo:
The question as to whether it is better to diversify a real estate portfolio within a property type across the regions or within a region across the property types is one of continuing interest for academics and practitioners alike. The current study, however, is somewhat different from the usual sector/regional analysis taking account of the fact that holdings in the UK real estate market are heavily concentrated in a single region, London. As a result this study is designed to investigate whether a real estate fund manager can obtain a statistically significant improvement in risk/return performance from extending out of a London based portfolio into firstly the rest of the South East of England and then into the remainder of the UK, or whether the manger would be better off staying within London and diversifying across the various property types. The results indicating that staying within London and diversifying across the various property types may offer performance comparable with regional diversification, although this conclusion largely depends on the time period and the fund manager’s ability to diversify efficiently.
Resumo:
This paper provides a comparative study of the performance of cross-flow and counter-flow M-cycle heat exchangers for dew point cooling. It is recognised that evaporative cooling systems offer a low energy alternative to conventional air conditioning units. Recently emerged dew point cooling, as the renovated evaporative cooling configuration, is claimed to have much higher cooling output over the conventional evaporative modes owing to use of the M-cycle heat exchangers. Cross-flow and counter-flow heat exchangers, as the available structures for M-cycle dew point cooling processing, were theoretically and experimentally investigated to identify the difference in cooling effectiveness of both under the parallel structural/operational conditions, optimise the geometrical sizes of the exchangers and suggest their favourite operational conditions. Through development of a dedicated computer model and case-by-case experimental testing and validation, a parametric study of the cooling performance of the counter-flow and cross-flow heat exchangers was carried out. The results showed the counter-flow exchanger offered greater (around 20% higher) cooling capacity, as well as greater (15%–23% higher) dew-point and wet-bulb effectiveness when equal in physical size and under the same operating conditions. The cross-flow system, however, had a greater (10% higher) Energy Efficiency (COP). As the increased cooling effectiveness will lead to reduced air volume flow rate, smaller system size and lower cost, whilst the size and cost are the inherent barriers for use of dew point cooling as the alternation of the conventional cooling systems, the counter-flow system is considered to offer practical advantages over the cross-flow system that would aid the uptake of this low energy cooling alternative. In line with increased global demand for energy in cooling of building, largely by economic booming of emerging developing nations and recognised global warming, the research results will be of significant importance in terms of promoting deployment of the low energy dew point cooling system, helping reduction of energy use in cooling of buildings and cut of the associated carbon emission.
Resumo:
This paper assesses the performance of a vocabulary test designed to measure second language productive vocabulary knowledge.The test, Lex30, uses a word association task to elicit vocabulary, and uses word frequency data to measure the vocabulary produced. Here we report firstly on the reliability of the test as measured by a test-retest study, a parallel test forms experiment and an internal consistency measure. We then investigate the construct validity of the test by looking at changes in test performance over time, analyses of correlations with scores on similar tests, and comparison of spoken and written test performance. Last, we examine the theoretical bases of the two main test components: eliciting vocabulary and measuring vocabulary. Interpretations of our findings are discussed in the context of test validation research literature. We conclude that the findings reported here present a robust argument for the validity of the test as a research tool, and encourage further investigation of its validity in an instructional context
Resumo:
We extend the theory of the multinational enterprise (MNE) by exploring the concept of subsidiary-specific advantages (SSAs) as a driver for subsidiary performance. We investigate the relationship of host country-specific advantages (host CSAs) in the form of market attractiveness, SSAs and subsidiary sales as they affect subsidiary performance. From an original primary dataset of 101 British multinational (MNE) subsidiaries in six South East Asian countries, our analysis reveals three significant findings. First, host market attractiveness has a statistically positive impact on the performance of subsidiaries. Second, the three traditional SSAs of general management, marketing capabilities and invested capital enhance subsidiary performance. Third, we examine geographic direction and types of customers for subsidiary sales by following international accounting standards. We find that these subsidiaries generate on average 95 percent of total sales from the Asia Pacific region and 91 percent of total sales from external customers. Our findings have important research and managerial implications.