27 resultados para Dielectric response measurements
em CentAUR: Central Archive University of Reading - UK
Resumo:
We discuss the modeling of dielectric responses of electromagnetically excited networks which are composed of a mixture of capacitors and resistors. Such networks can be employed as lumped-parameter circuits to model the response of composite materials containing conductive and insulating grains. The dynamics of the excited network systems are studied using a state space model derived from a randomized incidence matrix. Time and frequency domain responses from synthetic data sets generated from state space models are analyzed for the purpose of estimating the fraction of capacitors in the network. Good results were obtained by using either the time-domain response to a pulse excitation or impedance data at selected frequencies. A chemometric framework based on a Successive Projections Algorithm (SPA) enables the construction of multiple linear regression (MLR) models which can efficiently determine the ratio of conductive to insulating components in composite material samples. The proposed method avoids restrictions commonly associated with Archie’s law, the application of percolation theory or Kohlrausch-Williams-Watts models and is applicable to experimental results generated by either time domain transient spectrometers or continuous-wave instruments. Furthermore, it is quite generic and applicable to tomography, acoustics as well as other spectroscopies such as nuclear magnetic resonance, electron paramagnetic resonance and, therefore, should be of general interest across the dielectrics community.
Resumo:
Hypothesis: The aim of this study was to measure the mass loading effect of an active middle-ear implant (the Vibrant Soundbridge) in cadaver temporal bones. Background: Implantable middle ear hearing devices such as Vibrant Soundbridge have been used as an alternative to conventional hearing aids for the rehabilitation of sensorineural hearing loss. Other than the obvious disadvantage of requiring implantation middle ear surgery, it also applies a direct weight on the ossicular chain which, in turn, may have an impact on residual hearing. Previous studies have shown that applying a mass directly on the ossicular chain has a damping effect on its response to sound. However, little has been done to investigate the magnitude and the frequency characteristics of the mass loading effect in devices such as the Vibrant Soundbridge. Methods: Five fresh cadaver temporal bones were used. The stapes displacement was measured using laser Doppler vibrometry before and after the placement of a Vibrant Sound-bridge floating mass transducer. The effects of mass and attachment site were compared with the unloaded response. Measurements were obtained at frequencies between 0.1 and 10 kHz and at acoustic input levels of 100 dB sound pressure level. Each temporal bone acted as its own control. Results: Placement of the floating mass transducer caused a reduction of the stapes displacement. There were variations between the bones. The change of the stapes displacement varied from 0 dB to 28 dB. The effect was more prominent at frequencies above 1,000 Hz. Placing the floating mass transducer close to the incudostapedial joint reduced the mass loading effect. Conclusion: The floating mass transducer produces a measurable reduction of the stapes displacement in the temporal bone model. The effect is more prominent at high frequencies.
Resumo:
This work discusses the use of a THz-transient spectrometer for the measurement of tissue water content. The relation of both mammalian- and plant-cell water content to the osmotic potential is discussed. The process of equilibration of tissue water potential with the water potential of water vapor in an osmometer cuvette is described. Observation of the THz transmittance through the water vapor provides a measure of the water activity and water potential in the sample. The possibility of performing dielectric relaxation measurements of the liquid water in the tissue at THz frequencies directly and the use of proline as marker of water stress in tissue are discussed.
Resumo:
Microcontroller-based peak current mode control of a buck converter is investigated. The new solution uses a discrete time controller with digital slope compensation. This is implemented using only a single-chip microcontroller to achieve desirable cycle-by-cycle peak current limiting. The digital controller is implemented as a two-pole, two-zero linear difference equation designed using a continuous time model of the buck converter and a discrete time transform. Subharmonic oscillations are removed with digital slope compensation using a discrete staircase ramp. A 16 W hardware implementation directly compares analog and digital control. Frequency response measurements are taken and it is shown that the crossover frequency and expected phase margin of the digital control system match that of its analog counterpart.
Resumo:
The first measurement of the relative permittivity (εr) and loss tangent (tan δ) of EPON™ SU-8 advanced thick film ultraviolet photoresist is reported at frequencies between 75–110 GHz (W-band). The problems associated with such a measurement are discussed, an error analysis given, and values of εr=1.725±0.08 and tanδ =0.02±0.001 are determined.
Resumo:
A quasi-optical de-embedding technique for characterizing waveguides is demonstrated using wideband time-resolved terahertz spectroscopy. A transfer function representation is adopted for the description of the signal in the input and output port of the waveguides. The time domain responses were discretised and the waveguide transfer function was obtained through a parametric approach in the z-domain after describing the system with an ARX as well as with a state space model. Prior to the identification procedure, filtering was performed in the wavelet domain to minimize signal distortion and the noise propagating in the ARX and subspace models. The model identification procedure requires isolation of the phase delay in the structure and therefore the time-domain signatures must be firstly aligned with respect to each other before they are compared. An initial estimate of the number of propagating modes was provided by comparing the measured phase delay in the structure with theoretical calculations that take into account the physical dimensions of the waveguide. Models derived from measurements of THz transients in a precision WR-8 waveguide adjustable short will be presented.
Resumo:
Accurate estimation of the soil water balance (SWB) is important for a number of applications (e.g. environmental, meteorological, agronomical and hydrological). The objective of this study was to develop and test techniques for the estimation of soil water fluxes and SWB components (particularly infiltration, evaporation and drainage below the root zone) from soil water records. The work presented here is based on profile soil moisture data measured using dielectric methods, at 30-min resolution, at an experimental site with different vegetation covers (barley, sunflower and bare soil). Estimates of infiltration were derived by assuming that observed gains in the soil profile water content during rainfall were due to infiltration. Inaccuracies related to diurnal fluctuations present in the dielectric-based soil water records are resolved by filtering the data with adequate threshold values. Inconsistencies caused by the redistribution of water after rain events were corrected by allowing for a redistribution period before computing water gains. Estimates of evaporation and drainage were derived from water losses above and below the deepest zero flux plane (ZFP), respectively. The evaporation estimates for the sunflower field were compared to evaporation data obtained with an eddy covariance (EC) system located elsewhere in the field. The EC estimate of total evaporation for the growing season was about 25% larger than that derived from the soil water records. This was consistent with differences in crop growth (based on direct measurements of biomass, and field mapping of vegetation using laser altimetry) between the EC footprint and the area of the field used for soil moisture monitoring. Copyright (c) 2007 John Wiley & Sons, Ltd.
Resumo:
The 11-yr solar cycle temperature response to spectrally resolved solar irradiance changes and associated ozone changes is calculated using a fixed dynamical heating (FDH) model. Imposed ozone changes are from satellite observations, in contrast to some earlier studies. A maximum of 1.6 K is found in the equatorial upper stratosphere and a secondary maximum of 0.4 K in the equatorial lower stratosphere, forming a double peak in the vertical. The upper maximum is primarily due to the irradiance changes while the lower maximum is due to the imposed ozone changes. The results compare well with analyses using the 40-yr ECMWF Re-Analysis (ERA-40) and NCEP/NCAR datasets. The equatorial lower stratospheric structure is reproduced even though, by definition, the FDH calculations exclude dynamically driven temperature changes, suggesting an important role for an indirect dynamical effect through ozone redistribution. The results also suggest that differences between the Stratospheric Sounding Unit (SSU)/Microwave Sounding Unit (MSU) and ERA-40 estimates of the solar cycle signal can be explained by the poor vertical resolution of the SSU/MSU measurements. The adjusted radiative forcing of climate change is also investigated. The forcing due to irradiance changes was 0.14 W m−2, which is only 78% of the value obtained by employing the standard method of simple scaling of the total solar irradiance (TSI) change. The difference arises because much of the change in TSI is at wavelengths where ozone absorbs strongly. The forcing due to the ozone change was only 0.004 W m−2 owing to strong compensation between negative shortwave and positive longwave forcings.
Resumo:
Cercal hairs represent in cricket a wind sensitive escape system, able to detect the airflow generated from predating species. These sensors have been studied as a biomimetic concept to allow the development of MEMS for biomedical use. In particular, the behaviour of the hairs, including airflow response, resonant frequency and damping, has been investigated up to a frequency of 20 kHz. The microscopic nature of the hairs, the complex vibrations of excited hairs and the high damping of the system suggested that the use of Laser Doppler vibrometry could possibly improve the test performance. Two types of tests were performed: in the first case the hairs were indirectly excited using the signal obtained from a vibrating aluminium plate, whilst in the second case the hairs were directly excited using a white noise chirp. The results from the first experiment indicated that the hairs move in-phase with the exciting signal up to frequencies in the order of 10 kHz, responding to the vibration modes of the plate with a signal attenuation of 12 to 20 dB. The chirp experiment revealed the presence of rotational resonant modes at 6850 and 11300 Hz. No clear effect of hair length was perceivable on the vibration response of the filiform sensors. The obtained results proved promising to support the mechanical and vibration characterisation of the hairs and suggest that scanning Laser vibrometry can be used extensively on highly dampened biological materials.
Resumo:
Bubbles impart a very unique texture, chew, and mouth feel to foods. However, little is known about the relationship between structure of such products and consumer response in terms of mouth-feel and eating experience. The objective of this article is to investigate the sensory properties of 4 types of bubble-containing chocolates, produced by using different gases: carbon dioxide, nitrogen, nitrous oxide, and argon. The structure of these chocolates were characterized in terms of (1) gas hold-up values determined by density measurements and (2) bubble size distribution which was measured by undertaking an image analysis of X-ray microtomograph sections. Bubble size distributions were obtained by measuring bubble volumes after reconstructing 3D images from the tomographic sections. A sensory study was undertaken by a nonexpert panel of 20 panelists and their responses were analyzed using qualitative descriptive analysis (QDA). The results show that chocolates made from the 4 gases could be divided into 2 groups on the basis of bubble volume and gas hold-up: the samples produced using carbon dioxide and nitrous oxide had a distinctly higher gas hold-up containing larger bubbles in comparison with those produced using argon and nitrogen. The sensory study also demonstrated that chocolates made with the latter were perceived to be harder, less aerated, slow to melt in the mouth, and having overall flavor intensity. These products were further found to be creamier than the chocolates made by using carbon dioxide and nitrous oxide; the latter sample also showed a higher intensity of cocoa flavor.
Resumo:
The average UK adult consumes less than three portions of fruit and vegetables daily, despite evidence to suggest that consuming five portions daily could help prevent chronic diseases. It is recommended that fruit juice should only count as one of these portions, as juicing removes fibre and releases sugars. However, fruit juices contain beneficial compounds such as vitamin C and flavonoids and could be a useful source of dietary phytochemicals. Two randomised controlled cross-over intervention studies investigating the effects of chronic and acute consumption of commercially-available fruit- and vegetable-puree-based drinks (FVPD) on bioavailability, antioxidant status and CVD risk factors are described. Blood and urine samples were collected during both studies and vascular tone was measured using laser Doppler imaging. In the chronic intervention study FVPD consumption was found to significantly increase dietary carotenoids (P = 0.001) and vitamin C (P = 0.003). Plasma carotenoids were increased (P = 0.001), but the increase in plasma vitamin C was not significant. There were no significant effects on oxidative stress, antioxidant status and other CVD risk factors. In the acute intervention study FVPD were found to increase total plasma nitrate and nitrite (P = 0.001) and plasma vitamin C (P = 0.002). There was no effect on plasma lipids or uric acid, but there was a lower glucose and insulin peak concentration after consumption of the FVPD compared with the sugar-matched control. There was a trend towards increased vasodilation following both chronic and acute FVPD consumption. All volunteers were retrospectively genotyped for the eNOS G298T polymorphism and the effect of genotype on the measurements is discussed. Overall, there was a non-significant trend towards increased endothelium-dependent vasodilation following both acute and chronic FVPD consumption. However, there was a significant time x treatment effect (P < 0.05) of acute FVPD consumption in individuals with the GG variant of the eNOS gene.
Resumo:
OBJECTIVES: To test the hypothesis that a micronutrient supplement can improve seroconversion after influenza immunization in older institutionalized people. DESIGN: Randomized, double-blind, placebo-controlled study. SETTING: Nursing and residential homes in Liverpool, United Kingdom. PARTICIPANTS: One hundred sixty-four residents aged 60 and older from 31 homes were initially randomized; of these, 119 (72.6%) completed the study. INTERVENTION: Participants were randomized to receive a micronutrient supplement providing the reference nutrient intake for all vitamins and trace elements or identical placebo. Tablets were taken over an 8-week period during September and October 2000; influenza vaccine was administered 4 weeks after their commencement. MEASUREMENTS: The hemagglutination-inhibiting antibody response as defined by a fourfold or greater titer rise over 4 weeks and assessed separately for each of the three antigens contained in the 2000/2001 influenza vaccine (A/New Caledonia/20/99 (H1N1), A/Moscow/10/99 (H3N2), B/Beijing/184/93 (B)). RESULTS: Despite a significant increase in serum concentrations of vitamins A, C, D-3, E, folate, and selenium in the supplemented group, there was no significant difference between groups (supplemented vs placebo, respectively) in the proportion of participants seroconverting to H1N1 (41% vs 49%, P=.374), H3N2 (49% vs 58%, P=.343), or B (41% vs 40%, P=.944). CONCLUSION: A micronutrient supplement providing the reference nutrient intake administered over 8 weeks had no beneficial effect on antibody response to influenza vaccine in older people living in long-term care.
Resumo:
A quasi-optical deembedding technique for characterizing waveguides is demonstrated using wide-band time-resolved terahertz spectroscopy. A transfer function representation is adopted for the description of the signal in the input and output port of the waveguides. The time-domain responses were discretized and the waveguide transfer function was obtained through a parametric approach in the z-domain after describing the system with an AutoRegressive with eXogenous input (ARX), as well as with a state-space model. Prior to the identification procedure, filtering was performed in the wavelet domain to minimize both signal distortion, as well as the noise propagating in the ARX and subspace models. The optimal filtering procedure used in the wavelet domain for the recorded time-domain signatures is described in detail. The effect of filtering prior to the identification procedures is elucidated with the aid of pole-zero diagrams. Models derived from measurements of terahertz transients in a precision WR-8 waveguide adjustable short are presented.