18 resultados para Computerised tomography

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ray micro-tomography is a well-established technique for non-invasive imaging and evaluation of heterogeneous materials. An inexpensive X-ray micro-tomography system has been designed and built for the specific purposes of examining root growth and root/soil interactions. The system uses a silver target X-ray source with a focal spot diameter of 80 mum, an X-ray image intensifier with a sampling aperture of about 100 mum, and a sample with a diameter of 25 mm. Pre-germinated wheat and rape seeds were grown for up to 8-10 days in plastic containers in a sandy loam soil sieved to < 250 μm, and imaged with the X-ray system at regular intervals. The quality of 3 D image obtained was good allowing the development and growth of both root axes and some first-order laterals to be observed. The satisfactory discrimination between soil and roots enabled measurements of root diameter (wheat values were 0.48-1.22 mm) in individual tomographic slices and, by tracking from slice to slice, root lengths were also measured. The measurements obtained were generally within 10% of those obtained from destructive samples measured manually and with a flat-bed scanner. Further developments of the system will allow more detailed examination of the root: soil interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An X-ray micro-tomography system has been designed that is dedicated to the low-dose imaging of radiation sensitive living organisms and has been used to image the early development of the first few days of plant development immediately after germination. The system is based on third-generation X-ray micro-tomography system and consists of an X-ray tube, two-dimensional X-ray detector and a mechanical sample manipulation stage. The X-ray source is a 50 kVp X-ray tube with a silver target with a filter to centre the X-ray spectrum on 22 keV.A 100 mm diameter X-ray image intensifier (XRII) is used to collect the two-dimensional projection images. The rotation tomography table incorporates a linear translation mechanism to eliminate ring artefact that is commonly associated with third-generation tomography systems' Developing maize seeds (Triticum aestivum) have been imaged using the system with a cubic voxel linear dimension of 100 mum, over a diameter of 25 mm and the root lengths and volumes measured. The X-ray dose to the plants was also assessed and found to have no effect on the plant root development. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new wave of computerised therapy is under development which, rather than simulating talking therapies, uses bias modification techniques to target the core psychological process underlying anxiety. Such interventions are aimed at anxiety disorders, and are yet to be adapted for co-morbid anxiety in psychosis. The cognitive bias modification (CBM) paradigm delivers repeated exposure to stimuli in order to train individuals to resolve ambiguous information in a positive, rather than anxiety provoking, manner. The current study is the first to report data from a modified form of CBM which targets co-morbid anxiety within individuals diagnosed with schizophrenia. Our version of CBM involved exposure to one hundred vignettes presented over headphones. Participants were instructed to actively simulate the described scenarios via visual imagery. Twenty-one participants completed both a single session of CBM and a single control condition session in counter-balanced order. Within the whole sample, there was no significant improvement on interpretation bias of CBM or state anxiety, relative to the control condition. However, in line with previous research, those participants who engage in higher levels of visual imagery exhibited larger changes in interpretation bias. We discuss the implications for harnessing computerised CBM therapy developments for co-morbid anxiety in schizophrenia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the intonation of Chinese and Arabic learners of English using the computerized test battery Profiling Elements of Prosody for Speech and Communication (PEPS-C). The aims were to ascertain which aspects of intonation are difficult for these learners, and to determine whether PEPS-C can be used to assess the intonation of adult learners. Although some results were significantly different from native-speaker data, raw scores showed that the learner groups performed well in most tasks, which may indicate that the learners' level is too high for the PEPS-C to be useful. However, the PEPS-C did reveal that Arabic learners performed significantly worse at contrastive stress placement, and Chinese learners performed significantly worse assessing likes and dislikes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we explore classification techniques for ill-posed problems. Two classes are linearly separable in some Hilbert space X if they can be separated by a hyperplane. We investigate stable separability, i.e. the case where we have a positive distance between two separating hyperplanes. When the data in the space Y is generated by a compact operator A applied to the system states ∈ X, we will show that in general we do not obtain stable separability in Y even if the problem in X is stably separable. In particular, we show this for the case where a nonlinear classification is generated from a non-convergent family of linear classes in X. We apply our results to the problem of quality control of fuel cells where we classify fuel cells according to their efficiency. We can potentially classify a fuel cell using either some external measured magnetic field or some internal current. However we cannot measure the current directly since we cannot access the fuel cell in operation. The first possibility is to apply discrimination techniques directly to the measured magnetic fields. The second approach first reconstructs currents and then carries out the classification on the current distributions. We show that both approaches need regularization and that the regularized classifications are not equivalent in general. Finally, we investigate a widely used linear classification algorithm Fisher's linear discriminant with respect to its ill-posedness when applied to data generated via a compact integral operator. We show that the method cannot stay stable when the number of measurement points becomes large.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a new reconstruction method for diffuse optical tomography using reduced-order models of light transport in tissue. The models, which directly map optical tissue parameters to optical flux measurements at the detector locations, are derived based on data generated by numerical simulation of a reference model. The reconstruction algorithm based on the reduced-order models is a few orders of magnitude faster than the one based on a finite element approximation on a fine mesh incorporating a priori anatomical information acquired by magnetic resonance imaging. We demonstrate the accuracy and speed of the approach using a phantom experiment and through numerical simulation of brain activation in a rat's head. The applicability of the approach for real-time monitoring of brain hemodynamics is demonstrated through a hypercapnic experiment. We show that our results agree with the expected physiological changes and with results of a similar experimental study. However, by using our approach, a three-dimensional tomographic reconstruction can be performed in ∼3  s per time point instead of the 1 to 2 h it takes when using the conventional finite element modeling approach

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One quarter of children and young people (CYP) experience anxiety and/or depression before adulthood, but treatment is sometimes unavailable or inadequate. Self-help interventions may have a role in augmenting treatment and this work aimed to systematically review the evidence for computerised anxiety and depression interventions in CYP aged 5–25 years old. Databases were searched for randomised controlled trials and 27 studies were identified. For young people (12–25 years) with risk of diagnosed anxiety disorders or depression, computerised CBT (cCBT) had positive effects for symptoms of anxiety (SMD −0.77, 95% CI −1.45 to −0.09, k = 6, N = 220) and depression (SMD −0.62, 95% CI −1.13 to −0.11, k = 7, N = 279). In a general population study of young people, there were small positive effects for anxiety (SMD −0.15, 95% CI −0.26 to −0.03; N = 1273) and depression (SMD −0.15, 95% CI −0.26 to −0.03; N = 1280). There was uncertainty around the effectiveness of cCBT in children (5–11 years). Evidence for other computerised interventions was sparse and inconclusive. Computerised CBT has potential for treating and preventing anxiety and depression in clinical and general populations of young people. Further program development and research is required to extend its use and establish its benefit in children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of auditory-verbal short-term memory (STM) deficits in aphasia is a growing avenue of research (Martin & Reilly, 2012; Murray, 2012). STM treatment requires time precision, which is suited to computerised delivery. We have designed software, which provides STM treatment for aphasia. The treatment is based on matching listening span tasks (Howard & Franklin, 1990), aiming to improve the temporal maintenance of multi-word sequences (Salis, 2012). The person listens to pairs of word-lists that differ in word-order and decides if the pairs are the same or different. This approach does not require speech output and is suitable for persons with aphasia who have limited or no output. We describe the software and how its review from clinicians shaped its design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Short-term memory (STM) impairments are prevalent in adults with acquired brain injuries. While there are several published tests to assess these impairments, the majority require speech production, e.g. digit span (Wechsler, 1987). This feature may make them unsuitable for people with aphasia and motor speech disorders because of word finding difficulties and speech demands respectively. If patients perceive the speech demands of the test to be high, the may not engage with testing. Furthermore, existing STM tests are mainly ‘pen-and-paper’ tests, which can jeopardise accuracy. To address these shortcomings, we designed and standardised a novel computerised test that does not require speech output and because of the computerised delivery it would enable clinicians identify STM impairments with greater precision than current tests. The matching listening span tasks, similar to the non-normed PALPA 13 (Kay, Lesser & Coltheart, 1992) is used to test short-term memory for serial order of spoken items. Sequences of digits are presented in pairs. The person hears the first sequence, followed by the second sequence and s/he decides whether the two sequences are the same or different. In the computerised test, the sequences are presented in live voice recordings on a portable computer through a software application (Molero Martin, Laird, Hwang & Salis 2013). We collected normative data from healthy older adults (N=22-24) using digits, real words (one- and two-syllables) and non-words (one- and two- syllables). Their performance was scored following two systems. The Highest Span system was the highest span length (e.g. 2-8) at which a participant correctly responded to over 7 out of 10 trials at the highest sequence length. Test re-test reliability was also tested in a subgroup of participants. The test will be available as free of charge for clinicians and researchers to use.