37 resultados para Agronomy course

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soil moisture content, theta, of a bare and vegetated UK gravelly sandy loam soil (in situ and repacked in small lysimeters) was measured using various dielectric instruments (single-sensor ThetaProbes, multi-sensor Profile Probes, and Aquaflex Sensors), at depths ranging between 0.03 and I m, during the summers of 2001 (in situ soil) and 2002 (mini-lysimeters). Half-hourly values of evaporation, E, were calculated from diurnal changes in total soil profile water content, using the soil water balance equation. For the bare soil field, Profile Probes and ML2x ThetaProbes indicated a diurnal course of theta that did not concur with typical soil physical observations: surface layer soil moisture content increased from early morning until about midday, after which theta declined, generally until the early evening. The unexpected course of theta was positively correlated to soil temperature, T-s, also at deeper depths. Aquaflex and ML1 ThetaProbe (older models) outputs, however, reflected common observations: 0 increased slightly during the night (capillary rise) and decreased from the morning until late afternoon (as a result of evaporation). For the vegetated plot, the spurious diurnal theta fluctuations were less obvious, because canopy shading resulted in lower amplitudes of T-s. The unrealistic theta profiles measured for the bare and vegetated field sites caused diurnal estimates of E to attain downward daytime and upward night-time values. In the mini-lysimeters, at medium to high moisture contents, theta values measured by (ML2x) ThetaProbes followed a relatively realistic course, and predictions of E from diurnal changes in vertically integrated theta generally compared well with lysimeter estimates of E. However, time courses of theta and E became comparable to those observed for the field plots when the soil in the lysimeters reached relatively low values of theta. Attempts to correct measured theta for fluctuations in T, revealed that no generally applicable formula could be derived. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hazards associated with high voltage three phase inverters and the rotating shafts of large electrical machines have resulted in most of the engineering courses covering these topics to be predominantly theoretical. This paper describes a set of purpose built, low voltage and low cost teaching equipment which allows the "hands on" instruction of three phase inverters and rotating machines. By using low voltages, the student can experiment freely with the motors and inverter and can access all of the current and voltage waveforms, which until now could only be studied in text books or observed as part of laboratory demonstrations. Both the motor and the inverter designs are optimized for teaching purposes cost around $25 and can be made with minimal effort.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hazards associated with high-voltage three-phase inverters and high-powered large electrical machines have resulted in most of the engineering courses covering three-phase machines and drives theoretically. This paper describes a set of purpose-built, low-voltage, and low-cost teaching equipment that allows the hands-on instruction of three-phase inverters and rotating machines. The motivation for moving towards a system running at low voltages is that the students can safely experiment freely with the motors and inverter. The students can also access all of the current and voltage waveforms, which until now could only be studied in textbooks or observed as part of laboratory demonstrations. Both the motor and the inverter designs are for teaching purposes and require minimal effort and cost

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent biochemical studies have identified high molecular complexes of the HIV Gag precursor in the cytosol of infected cells. Using immunoelectron microscopy we studied the time course of the synthesis and assembly of a HIV Gag precursor protein (pr55gag) in Sf9 cells infected with recombinant baculovirus expressing the HIV gag gene. We also immunolabeled for pr55gag human T4 cells acutely or chronically infected with HIV-1. In Sf9 cells, the time course study showed that the first Gag protein appeared in the cytoplasm at 28-30 h p.i. and that budding started 6-8 h later. Colloidal gold particles, used to visualize the Gag protein, were first scattered randomly throughout the cytoplasm, but soon clusters representing 100 to 1000 copies of pr55gag were also observed. By contrast, in cells with budding or released virus-like particles the cytoplasm was virtually free of gold particles while the released virus-like particles were heavily labeled. Statistical analysis showed that between 80 and 90% of the gold particles in the cytoplasm were seen as singles, as doublets, or in small groups of up to five particles probably representing small oligomers. Clusters of gold particles were also observed in acutely infected lymphocytes as well as in multinuclear cells of chronically infected cultures of T4 cells. In a few cases small aggregates of gold particles were found in the nuclei of T4 lymphocytes. These observations suggest that the Gag polyprotein forms small oligomers in the cytoplasm of expressing cells but that assembly into multimeric complexes takes place predominantly at the plasma membrane. Large accumulations of Gag protein in the cytoplasm may represent misfolded molecules destined for degradation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hazards associated with high voltage three phase inverters ond the rotating sha@s of large electrical machines have resulted in most of the engineering courses covering these topics to be predominantly theoretical. This paper describes a set of purpose built, low voltage and low cost teaching equipment which allows the “hands on I’ instruction of three phase inverters and rotating machines. By using low voltages, the student can experiment freely with the motors and inverter and can access all of the current and voltage waveforms, which until now could only be studied in text books or observed as part of laboratory demonstrations. Both the motor and the inverter designs are optimized for teaching purposes, cost around $25 and can be made with minimal effort.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hazards associated with high-voltage three-phase inverters and high-powered large electrical machines have resulted in most of the engineering courses covering three-phase machines and drives theoretically. This paper describes a set of purpose-built, low-voltage, and low-cost teaching equipment that allows the hands-on instruction of three-phase inverters and rotating machines. The motivation for moving towards a system running at low voltages is that the students can safely experiment freely with the motors and inverter. The students can also access all of the current and voltage waveforms, which until now could only be studied in textbooks or observed as part of laboratory demonstrations. Both the motor and the inverter designs are for teaching purposes and require minimal effort and cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selecting a stimulus as the target for a goal-directed movement involves inhibiting other competing possible responses. Both target and distractor stimuli activate populations of neurons in topographic oculomotor maps such as the superior colliculus. Local inhibitory interconnections between these populations ensure only one saccade target is selected. Suppressing saccades to distractors may additionally involve inhibiting corresponding map regions to bias the local competition. Behavioral evidence of these inhibitory processes comes from the effects of distractors on oculomotor and manual trajectories. Individual saccades may initially deviate either toward or away from a distractor, but the source of this variability has not been investigated. Here we investigate the relation between distractor-related deviation of trajectory and saccade latency. Targets were presented with, or without, distractors, and the deviation of saccade trajectories arising from the presence of distractors was measured. A fixation gap paradigm was used to manipulate latency independently of the influence of competing distractors. Shorter- latency saccades deviated toward distractors and longer-latency saccades deviated away from distractors. The transition between deviation toward or away from distractors occurred at a saccade latency of around 200 ms. This shows that the time course of the inhibitory process involved in distractor related suppression is relatively slow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case study uses log-linear modelling to investigate the interrelationships between factors that may contribute to the late submission of coursework by undergraduate students. A class of 86 computing students are considered. These students were exposed to traditional teaching methods supported by e-learning via a Managed Learning Environment (MLE). The MLE warehouses detailed data about student usage of the various areas of the environment, which can be used to interpret the approach taken to learning. The study investigates the interrelationship between these factors with the information as to whether the student handed in their course work on time or whether they were late. The results from the log-linear modelling technique show that there is an interaction between participating in Discussions within the MLE and the timely submission of course work, indicating that participants are more likely to hand in on time, than those students who do not participate.