3 resultados para --1898-1986

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Disequilibria between Pb-210 and Ra-226 can be used to trace magma degassing, because the intermediate nuclides, particularly Rn-222, are volatile. Products of the 1980-1986 eruptions of Mount St. Helens have been analysed for (Pb-210/Ra-226). Both excesses and deficits of Pb-210 are encountered suggesting rapid gas transfer. The time scale of diffuse, non-eruptive gas escape prior to 1980 as documented by Pb-210 deficits is on the order of a decade using the model developed by Gauthier and Condomines (Earth Planet. Sci. Lett. 172 (1999) 111-126) for a non-renewed magma chamber and efficient Rn removal. The time required to build-up Pb-210 excess is much shorter (months) as can be observed from steady increases of (Pb-210/Ra-226) with time during 1980-1982. The formation of Pb-210 excess requires both rapid gas transport through the magma and periodic blocking of gas escape routes. Superposed on this time trend is the natural variability of (Pb-210/Ra-226) in a single eruption caused by tapping magma from various depths. The two time scales of gas transport, to create both Pb-210 deficits and Pb-210 excesses, cannot be reconciled in a single event. Rather Pb-210 deficits are associated with pre-eruptive diffuse degassing, while Pb-210 excesses document the more vigorous degassing associated with eruption and recharge of the system. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Historical smoke concentrations at monthly resolution for the early twentieth century are found for Kew Observatory, London, using the atmospheric electricity proxy technique. Smoke particles modify the electrical properties of urban air: an increase in smoke concentration reduces air's electrical conductivity and increases the Potential Gradient (PG). Calibrated PG data are available from Kew since 1898, and air conductivity was measured routinely between 1909 and 1979 using the technique developed by C.T.R. Wilson. Automated smoke observations at the same site overlap with the atmospheric electrical measurements from 1921, providing an absolute calibration to smoke concentration. This shows that the late nineteenth century winter smoke concentrations at Kew were approximately 100 times greater than contemporary winter smoke concentrations. Following smoke emission regulations reducing the smoke concentration, the electrical parameters of the urban air did not change dramatically. This is suggested to be due to a composition change, with an increase in the abundance of small aerosol compensating for the decrease in smoke. (c) 2006 Elsevier Ltd. All rights reserved.