185 resultados para flow recirculation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Small gaseous combustion systems are being targeted by strict pollution legislation which will provide challenges to reduce the NOx being emitted. A novel type of gas burner has been successfully designed and developed which incorporates a Coanda ejector to promote recirculation of flue gas from the burner exit. This provides a combustion system which gives very low emissions of NOx and CO, whilst maintaining a high degree of flame stability over a range of air/fuel ratios and fuel flow rates. Recirculation of flue gas was obtained by manipulating the aerodynamics of the system, without the aid of external duct work or moving parts. The design of the burner allowed very low pollutant emissions near stoichiometric conditions, resulting in high temperatures of the exit gas. Potential applications of this type of burner are in small and intermediate furnaces where low NOx emissions are required. Moreover, very high-temperature applications, such as glass furnaces could benefit in both cost and pollutant emissions from such a burner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High quality wind measurements in cities are needed for numerous applications including wind engineering. Such data-sets are rare and measurement platforms may not be optimal for meteorological observations. Two years' wind data were collected on the BT Tower, London, UK, showing an upward deflection on average for all wind directions. Wind tunnel simulations were performed to investigate flow distortion around two scale models of the Tower. Using a 1:160 scale model it was shown that the Tower causes a small deflection (ca. 0.5°) compared to the lattice on top on which the instruments were placed (ca. 0–4°). These deflections may have been underestimated due to wind tunnel blockage. Using a 1:40 model, the observed flow pattern was consistent with streamwise vortex pairs shed from the upstream lattice edge. Correction factors were derived for different wind directions and reduced deflection in the full-scale data-set by <3°. Instrumental tilt caused a sinusoidal variation in deflection of ca. 2°. The residual deflection (ca. 3°) was attributed to the Tower itself. Correction of the wind-speeds was small (average 1%) therefore it was deduced that flow distortion does not significantly affect the measured wind-speeds and the wind climate statistics are reliable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the spatial characteristics of urban-like canopy flow by applying particle image velocimetry (PIV) to atmospheric turbulence. The study site was a Comprehensive Outdoor Scale MOdel (COSMO) experiment for urban climate in Japan. The PIV system captured the two-dimensional flow field within the canopy layer continuously for an hour with a sampling frequency of 30 Hz, thereby providing reliable outdoor turbulence statistics. PIV measurements in a wind-tunnel facility using similar roughness geometry, but with a lower sampling frequency of 4 Hz, were also done for comparison. The turbulent momentum flux from COSMO, and the wind tunnel showed similar values and distributions when scaled using friction velocity. Some different characteristics between outdoor and indoor flow fields were mainly caused by the larger fluctuations in wind direction for the atmospheric turbulence. The focus of the analysis is on a variety of instantaneous turbulent flow structures. One remarkable flow structure is termed 'flushing', that is, a large-scale upward motion prevailing across the whole vertical cross-section of a building gap. This is observed intermittently, whereby tracer particles are flushed vertically out from the canopy layer. Flushing phenomena are also observed in the wind tunnel where there is neither thermal stratification nor outer-layer turbulence. It is suggested that flushing phenomena are correlated with the passing of large-scale low-momentum regions above the canopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to undertake repeat measurements of flow-mediated dilatation (FMD) within a short time of a previous measurement would be useful to improve accuracy or to repeat a failed initial procedure. Although standard methods report that a minimum of 10 min is required between measurements, there is no published data to support this. Thirty healthy volunteers had five FMD measurements performed within a 2-h period, separated by various time intervals (5, 15 and 30 min). In 19 volunteers, FMD was also performed as soon as the vessel had returned to its baseline diameter. There was no significant difference between any of the FMD measurements or parameters across the visits indicating that repeat measurements may be taken after a minimum of 5 min or as soon as the vessel has returned to its baseline diameter, which in some subjects may be less than 5 min.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the contemporaneous relationship between the intensity of the Indian Summer Monsoon (ISM) and runoff in the major rivers of the Aral Sea basin (Amudarya, Syrdarya) and some of their subcatchments. To this end, we use All-India rainfall (AIR) data, CRU surface observations of precipitation and temperature, ERA40 atmospheric data, and natural discharge data corrected for human interference. We show that there is a highly significant positive correlation between ISM intensity and Amudarya runoff. This finding cannot be explained by the spill-over of ISM precipitation over the Hindu Kush into the Amudarya basin. Instead, we suggest that the observed co-variability is mediated by tropospheric temperature variations due to fluctuations in the ISM intensity. These variations are known to be due to Rossby-wave propagation in response to condensational heating during monsoon precipitation. We hypothesise that the corresponding anomalies in surface temperatures imply anomalies in meltwater formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparison is made of the development of global orientation during shearing of lyotropic solutions of hydroxypropylcellulose with that observed for the thermotropic phase of hydroxypropylcellulose. At shear rates the behaviour of the two systems is similar, both during steady-state shear, and in terms of relaxation following cessation of shear flow. At low shear rates, the levels of orientation observed for the thermotropic system are substantially greater than observed for the lyotropic solutions. The relationship of these differences to variations in molecular parameters, viscous stress and to director tumbling is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel X-ray rheometer based on a parallel plate geometry is described. This system allows time-resolved X-ray scattering intensity data to be obtained from polymeric samples subjected to shear flow. The range of quantitative structural parameters, such as molecular orientation and inter chain correlations, which can be obtained from the data is highlighted. Examples of the utility of X-ray scattering in examining optically opaque samples and the extraction of 〈P2〉 and 〈P4〉 orientation parameters are given using anisotropic hydroxypropylcellulose solutions as the sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Global molecular orientation function coefficients for the nematic liquid crystal 4-cyano 4'-nn -pentylbiphenyl (5CB) in shear flow are presented, being extracted from 2-dimensional Wide-Angle X-ray Scattering data. A linear increase in orientation parameter P2 is observed with a logarithmic increase in shear rate. It is proposed that this arises from an increased number of LC directors aligning to the shear axis. Upon cessation of shear flow, the anisotropy is seen to relax away completely, over a time scale which is inversely proportional to the previously applied shear rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dispersion of a point-source release of a passive scalar in a regular array of cubical, urban-like, obstacles is investigated by means of direct numerical simulations. The simulations are conducted under conditions of neutral stability and fully rough turbulent flow, at a roughness Reynolds number of Reτ = 500. The Navier–Stokes and scalar equations are integrated assuming a constant rate release from a point source close to the ground within the array. We focus on short-range dispersion, when most of the material is still within the building canopy. Mean and fluctuating concentrations are computed for three different pressure gradient directions (0◦ , 30◦ , 45◦). The results agree well with available experimental data measured in a water channel for a flow angle of 0◦ . Profiles of mean concentration and the three-dimensional structure of the dispersion pattern are compared for the different forcing angles. A number of processes affecting the plume structure are identified and discussed, including: (i) advection or channelling of scalar down ‘streets’, (ii) lateral dispersion by turbulent fluctuations and topological dispersion induced by dividing streamlines around buildings, (iii) skewing of the plume due to flow turning with height, (iv) detrainment by turbulent dispersion or mean recirculation, (v) entrainment and release of scalar in building wakes, giving rise to ‘secondary sources’, (vi) plume meandering due to unsteady turbulent fluctuations. Finally, results on relative concentration fluctuations are presented and compared with the literature for point source dispersion over flat terrain and urban arrays. Keywords Direct numerical simulation · Dispersion modelling · Urban array

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyses the appraisal of a specialized form of real estate - data centres - that has a unique blend of locational, physical and technological characteristics that differentiate it from conventional real estate assets. Market immaturity, limited trading and a lack of pricing signals enhance levels of appraisal uncertainty and disagreement relative to conventional real estate assets. Given the problems of applying standard discounted cash flow, an approach to appraisal is proposed that uses pricing signals from traded cash flows that are similar to the cash flows generated from data centres. Based upon ‘the law of one price’, it is assumed that two assets that are expected to generate identical cash flows in the future must have the same value now. It is suggested that the expected cash flow of assets should be analysed over the life cycle of the building. Corporate bond yields are used to provide a proxy for the appropriate discount rates for lease income. Since liabilities are quite diverse, a number of proxies are suggested as discount and capitalisation rates including indexed-linked, fixed interest and zero-coupon bonds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A direct method is presented for determining the uncertainty in reservoir pressure, flow, and net present value (NPV) using the time-dependent, one phase, two- or three-dimensional equations of flow through a porous medium. The uncertainty in the solution is modelled as a probability distribution function and is computed from given statistical data for input parameters such as permeability. The method generates an expansion for the mean of the pressure about a deterministic solution to the system equations using a perturbation to the mean of the input parameters. Hierarchical equations that define approximations to the mean solution at each point and to the field covariance of the pressure are developed and solved numerically. The procedure is then used to find the statistics of the flow and the risked value of the field, defined by the NPV, for a given development scenario. This method involves only one (albeit complicated) solution of the equations and contrasts with the more usual Monte-Carlo approach where many such solutions are required. The procedure is applied easily to other physical systems modelled by linear or nonlinear partial differential equations with uncertain data.