125 resultados para HYDROPHOBIC MISMATCH


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Following previous studies, the aim of this work is to further investigate the application of colloidal gas aphrons (CGA) to the recovery of polyphenols from a grape marc ethanolic extract with particular focus on exploring the use of a non-ionic food grade surfactant (Tween 20) as an alternative to the more toxic cationic surfactant CTAB. Different batch separation trials in a flotation column were carried out to evaluate the influence of surfactant type and concentration and processing parameters (such as pH, drainage time, CGA/extract volumetric and molar ratio) on the recovery of total and specific phenolic compounds. The possibility of achieving selective separation and concentration of different classes of phenolic compounds and non-phenolic compounds was also assessed, together with the influence of the process on the antioxidant capacity of the recovered compounds. The process led to good recovery, limited loss of antioxidant capacity, but low selectivity under the tested conditions. Results showed the possibility of using Tween 20 with a separation mechanism mainly driven by hydrophobic interactions. Volumetric ratio rather than the molar ratio was the key operating parameter in the recovery of polyphenols by CGA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is a worldwide interest in the development of processes for producing colorants from natural sources. Microorganisms provide an alternative source of natural colorants produced by cultivation technology and extracted from the fermented broth. The aim of the present work was to study the recovery of red colorants from the fermented broth of Talaromyces amestolkiae using the technique of colloidal gas aphrons (CGA) comprising surfactant-stabilized microbubbles. Preliminary experiments were performed to evaluate the red colorants’ solubility in different organic solvents, octanol/water partitioning, and their stability in surfactant solutions, namely hexadecyl trimethylammonium bromide (CTAB), sodium dodecyl sulfate (SDS), and polyoxyethylenesorbitan monolaurate (Tween 20), which are cationic, anionic and nonionic surfactants, respectively. The first recovery experiments were carried out using CGA generated by these surfactants at different volumetric ratios (VR, 3–18). Subsequently, two different approaches to generate CGA were investigated at VR values of 6 and 12: the first involved the use of CTAB at pH 6.9–10.0, and the second involved the use of Tween 20 using red colorants partially dissolved in ethanol and Tween 20. The characterization results showed that red colorants have a hydrophilic nature. The highest recoveries were obtained with Tween 20 (78%) and CTAB (70%). These results demonstrated that the recovery of the colorants was driven by both electrostatic and hydrophobic interactions. The VR was found to be an important operating parameter and at VR 12 with CTAB (at pH 9) maximum recovery, partitioning coefficient (K = 5.39) and selectivity in relation to protein and sugar (SP = 3.75 and SS = 7.20 respectively) were achieved. Furthermore, with Tween 20, the separation was driven mainly by hydrophobic interactions. Overall CGA show promise for the recovery of red colorants from a fermented broth. Although better results were obtained with CTAB than with Tween 20 the latter may be more suitable for some application due to its lower toxicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present invention provides assay devices having a unitary body with an exterior surface, the unitary body being substantially transparent to visible light and formed from a material having a refractive index in the range 1.26 to 1.40, the refractive index being measured at 20 °C with light of wavelength 589 nm, and wherein the unitary body is formed from a hydrophobic material, and at least two capillary bores extending internally along the unitary body, wherein at least a portion of the surface of each capillary bore includes a hydrophilic layer for retaining an assay reagent, and wherein the hydrophilic layer is also substantially transparent to visible light to allow optical interrogation of the capillary bores through the capillary wall. The present invention also provides assay systems including such assay devices, methods of performing an assay using such assay devices and method of method for manufacturing such assay devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The self-assembly in aqueous solution of three novel telechelic conjugates comprising a central hydrophilic polymer and short (trimeric or pentameric) tyrosine end-caps has been investigated. Two of the conjugates have a central poly(oxyethylene) (polyethylene oxide, PEO) central block with different molar masses. The other conjugate has a central poly(l-alanine) (PAla) sequence in a purely amino-acid based conjugate. All three conjugates self-assemble into β-sheet based fibrillar structures, although the fibrillar morphology revealed by cryogenic-TEM is distinct for the three polymers—in particular the Tyr5-PEO6k-Tyr5 forms a population of short straight fibrils in contrast to the more diffuse fibril aggregates observed for Tyr5-PEO2k-Tyr5 and Tyr3-PAla-Tyr3. Hydrogel formation was not observed for these samples (in contrast to prior work on related systems) up to quite high concentrations, showing that it is possible to prepare solutions of peptide–polymer-peptide conjugates with hydrophobic end-caps without conformational constraints associated with hydrogelation. The Tyr5-PEO6k-Tyr5 shows significant PEO crystallization upon drying in contrast to the Tyr5-PEO2k-Tyr5 conjugate. Our findings point to the remarkable ability of short hydrophobic peptide end groups to modulate the self-assembly properties of polymers in solution in model peptide-capped “associative polymers”. Retention of fluidity at high conjugate concentration may be valuable in potential future applications of these conjugates as bioresponsive or biocompatible materials, for example exploiting the enzyme-responsiveness of the tyrosine end-groups

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study examines the processing of subject-verb (SV) number agreement with coordinate subjects in pre-verbal and post-verbal positions in Greek. Greek is a language with morphological number marked on nominal and verbal elements. Coordinate SV agreement, however, is special in Greek as it is sensitive to the coordinate subject's position: when pre-verbal, the verb is marked for plural while when post-verbal the verb can be in the singular. We conducted two experiments, an acceptability judgment task with adult monolinguals as a pre-study (Experiment 1) and a self-paced reading task as the main study (Experiment 2) in order to obtain acceptance as well as processing data. Forty adult monolingual speakers of Greek participated in Experiment 1 and a hundred and forty one in Experiment 2. Seventy one children participated in Experiment 2: 30 Albanian-Greek sequential bilingual children and 41 Greek monolingual children aged 10–12 years. The adult data in Experiment 1 establish the difference in acceptability between singular VPs in SV and VS constructions reaffirming our hypothesis. Meanwhile, the adult data in Experiment 2 show that plural verbs accelerate processing regardless of subject position. The child online data show that sequential bilingual children have longer reading times (RTs) compared to the age-matched monolingual control group. However, both child groups follow a similar processing pattern in both pre-verbal and post-verbal constructions showing longer RTs immediately after a singular verb when the subject was pre-verbal indicating a grammaticality effect. In the post-verbal coordinate subject sentences, both child groups showed longer RTs on the first subject following the plural verb due to the temporary number mismatch between the verb and the first subject. This effect was resolved in monolingual children but was still present at the end of the sentence for bilingual children indicating difficulties to reanalyze and integrate information. Taken together, these findings demonstrate that (a) 10–12 year-old sequential bilingual children are sensitive to number agreement in SV coordinate constructions parsing sentences in the same way as monolingual children even though their vocabulary abilities are lower than that of age-matched monolingual peers and (b) bilinguals are slower in processing overall.