454 resultados para Time Reading
Resumo:
Time-resolved kinetic studies of the reaction of silylene, SiH2, generated by laser flash photolysis of both silacyclopent-3-ene and phenylsilane, have been carried out to obtain second-order rate constants for its reaction with CH3Cl. The reaction was studied in the gas phase at six temperatures in the range 294-606 K. The second-order rate constants gave a curved Arrhenius plot with a minimum value at T approximate to 370 K. The reaction showed no pressure dependence in the presence of up to 100 Torr SF6. The rate constants, however, showed a weak dependence on laser pulse energy. This suggests an interpretation requiring more than one contributing reaction pathway to SiH2 removal. Apart from a direct reaction of SiH2 with CH3Cl, reaction of SiH2 with CH3 (formed by photodissociation of CH3Cl) seems probable, with contributions of up to 30% to the rates. Ab initio calculations (G3 level) show that the initial step of reaction of SiH2 with CH3Cl is formation of a zwitterionic complex (ylid), but a high-energy barrier rules out the subsequent insertion step. On the other hand, the Cl-abstraction reaction leading to CH3 + ClSiH2 has a low barrier, and therefore, this seems the most likely candidate for the main reaction pathway of SiH2 with CH3Cl. RRKM calculations on the abstraction pathway show that this process alone cannot account for the observed temperature dependence of the rate constants. The data are discussed in light of studies of other silylene reactions with haloalkanes.
First detection of methylgermylene in the gas phase and time-resolved study of some of its reactions
Resumo:
A new transient species has been produced and detected by the gas-phase, 193 nm laser flash photolysis of 1,3,4-trimethylgermacyclopent-3-ene, TMGCP. The species has strong visible absorptions in the wavelength region 450−520 nm (maximum at 485 nm) and is attributed to the germylene, MeGeH. Time-resolved kinetic studies have led to the first rate constants for its reactions with GeH4, Me2GeH2, C2H2, C2H4, C3H6, i-C4H8, TMGCP, MeOH, HCl, and SO2. The reactivity of MeGeH is compared to those of GeH2 and GeMe2. The Me-for-H substituent effect varies according to reaction type and is not constant from GeH2 to MeGeH to GeMe2.
Resumo:
In the past two decades, the geometric pathways involved in the transformations between inverse bicontinuous cubic phases in amphiphilic systems have been extensively theoretically modeled. However, little experimental data exists on the cubic-cubic transformation in pure lipid systems. We have used pressure-jump time-resolved X-ray diffraction to investigate the transition between the gyroid Q(II)(G) and double-diamond Q(II)(D) phases in mixtures of 1-monoolein in 30 wt% water. We find for this system that the cubic-cubic transition occurs without any detectable intermediate structures. In addition, we have determined the kinetics of the transition, in both the forward and reverse directions, as a function of pressure-jump amplitude, temperature, and water content. A recently developed model allows (at least in principle) the calculation of the activation energy for lipid phase transitions from such data. The analysis is applicable only if kinetic reproducibility is achieved, at least within one sample, and achievement of such kinetic reproducibility is shown here, by carrying out prolonged pressure-cycling. The rate of transformation shows clear and consistent trends with pressure-jump amplitude, temperature, and water content, all of which are shown to be in agreement with the effect of the shift in the position of the cubic-cubic phase boundary following a change in the thermodynamic parameters.
Resumo:
This paper presents the findings from a recent study funded by the Joseph Rowntree Foundation examining the housing and neighbourhood needs of 44 visually impaired children. Our research found that disabled people’s needs have been too narrowly based on ‘accessibility’ criteria, which do not take into account the health and safety issues so important for children. Indeed, the home environment is the main site of accidental death or injury for young children under 4 years, and children from low income families are particularly susceptible to burns, scalds, falls, swallowing foreign objects or poisonous substances within it (CRDU 1994). As disabled children are statistically more likely to be in low income families, this places them at high risk. If ‘accessibility’ is to be reconceived as design for usability throughout the lifecourse, this challenges us to move beyond the pragmatic but limited application of design prescriptions for disabled people as a separate and adult group, and to re-think all of the dimensions of the housing quality framework in the light of this expanded approach.
Resumo:
This research examines dynamics associated with new representational technologies in complex organizations through a study of the use of a Single Model Environment, prototyping and simulation tools in the mega-project to construct Terminal 5 at Heathrow Airport, London. The ambition of the client, BAA. was to change industrial practices reducing project costs and time to delivery through new contractual arrangements and new digitally-enabled collaborative ways of working. The research highlights changes over time and addresses two areas of 'turbulence' in the use of: 1) technologies, where there is a dynamic tension between desires to constantly improve, change and update digital technologies and the need to standardise practices, maintaining and defending the overall integrity of the system; and 2) representations, where dynamics result from the responsibilities and liabilities associated with sharing of digital representations and a lack of trust in the validity of data from other firms. These dynamics are tracked across three stages of this well-managed and innovative project and indicate the generic need to treat digital infrastructure as an ongoing strategic issue.
Resumo:
The purpose of this study was to apply and compare two time-domain analysis procedures in the determination of oxygen uptake (VO2) kinetics in response to a pseudorandom binary sequence (PRBS) exercise test. PRBS exercise tests have typically been analysed in the frequency domain. However, the complex interpretation of frequency responses may have limited the application of this procedure in both sporting and clinical contexts, where a single time measurement would facilitate subject comparison. The relative potential of both a mean response time (MRT) and a peak cross-correlation time (PCCT) was investigated. This study was divided into two parts: a test-retest reliability study (part A), in which 10 healthy male subjects completed two identical PRBS exercise tests, and a comparison of the VO2 kinetics of 12 elite endurance runners (ER) and 12 elite sprinters (SR; part B). In part A, 95% limits of agreement were calculated for comparison between MRT and PCCT. The results of part A showed no significant difference between test and retest as assessed by MRT [mean (SD) 42.2 (4.2) s and 43.8 (6.9) s] or by PCCT [21.8 (3.7) s and 22.7 (4.5) s]. Measurement error (%) was lower for MRT in comparison with PCCT (16% and 25%, respectively). In part B of the study, the VO2 kinetics of ER were significantly faster than those of SR, as assessed by MRT [33.4 (3.4) s and 39.9 (7.1) s, respectively; P<0.01] and PCCT [20.9 (3.8) s and 24.8 (4.5) s; P < 0.05]. It is possible that either analysis procedure could provide a single test measurement Of VO2 kinetics; however, the greater reliability of the MRT data suggests that this method has more potential for development in the assessment Of VO2 kinetics by PRBS exercise testing.
Resumo:
Time dependent gas hold-up generated in the 0.3 and 0.6 m diameter vessels using high viscosity castor oil and carboxy methyl cellulose (CMC) solution was compared on the basis of impeller speed (N) and gas velocity (V-G). Two types of hold-up were distinguished-the hold-up due to tiny bubbles (epsilon(ft)) and total hold-up (epsilon(f)), which included large and tiny bubbles. It was noted that vessel diameter (i.e. the scale of operation) significantly influences (i) the trends and the values of epsilon(f) and epsilon(ft), and (ii) the values of tau (a constant reflecting the time dependency of hold-up). The results showed that a scale independent correlation for gas hold-up of the form epsilon(f) or epsilon(ft) = A(N or P-G/V)(a) (V-G)(b), where "a" and "b" are positive constants is not appropriate for viscous liquids. This warrants further investigations into the effect of vessel diameter on gas hold-up in impeller agitated high viscosity liquids (mu or mu(a) > 0.4 Pa s). (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
A method is described for the analysis of deuterated and undeuterated alpha-tocopherol in blood components using liquid chromatography coupled to an orthogonal acceleration time-of-flight (TOF) mass spectrometer. Optimal ionisation conditions for undeuterated (d0) and tri- and hexadeuterated (d3 or d6) alpha-tocopherol standards were found with negative ion mode electrospray ionisation. Each species produced an isotopically resolved single ion of exact mass. Calibration curves of pure standards were linear in the range tested (0-1.5 muM, 0-15 pmol injected). For quantification of d0 and d6 in blood components following a standard solvent extraction, a stable-isotope-labelled internal standard (d3-alpha-tocopherol) was employed. To counter matrix ion suppression effects, standard response curves were generated following identical solvent extraction procedures to those of the samples. Within-day and between-day precision were determined for quantification of d0- and d6-labelled alpha-tocopherol in each blood component and both averaged 3-10%. Accuracy was assessed by comparison with a standard high-performance liquid chromatography (HPLC) method, achieving good correlation (r(2) = 0.94), and by spiking with known concentrations of alpha-tocopherol (98% accuracy). Limits of detection and quantification were determined to be 5 and 50 fmol injected, respectively. The assay was used to measure the appearance and disappearance of deuterium-labelled alpha-tocopherol in human blood components following deuterium-labelled (d6) RRR-alpha-tocopheryl acetate ingestion. The new LC/TOFMS method was found to be sensitive, required small sample volumes, was reproducible and robust, and was capable of high throughput when large numbers of samples were generated. Copyright (C) 2003 John Wiley Sons, Ltd.
Resumo:
Solvent influences on the crystallization of polymorph and hydrate forms of the nootropic drug piracetam (2-oxo-pyrrolidineacetamide) were investigated from water, methanol, 2-propanol, isobutanol, and nitromethane. Crystal growth profiles of piracetam polymorphs were constructed using time-resolved diffraction snapshots collected for each solvent system. Measurements were performed by in situ energy dispersive X-ray diffraction recorded in Station 16.4 at the synchrotron radiation source (SRS) at Daresbury Laboratory, CCLRC UK. Crystallizations from methanol, 2-propanol, isobutanol, and nitromethane progressed in a similar fashion with the initial formation of form I which then converted relatively quickly to form II with form III being generated upon further cooling. However, considerable differences were observed for the polymorphs lifetime and both the rate and temperature of conversion using the different solvents. The thermodynamically unstable form I was kinetically favored in isobutanol and nitromethane where traces of this polymorph were observed below 10 degrees C. In contrast, the transformation of form II and subsequent growth of form III were inhibited in 2-propanol and nitromethane solutions. Aqueous solutions produced hydrate forms of piracetam which are different from the reported monohydrate; this crystallization evolved through successive generation of transient structures which transformed upon exchange of intramolecular water between the liquid and crystalline phases. (c) 2007 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 96:1069-1078, 2007.
Resumo:
Determining rat preferences for, and behaviour towards, environmental enrichment objects allows us to provide evidence-based information about how the caged environment may be enriched. In recent years there have been many studies investigating the preferences of laboratory rodents for a wide variety of environmental enrichment objects and materials. While these have provided important information regarding the animals' perception of the items, very few studies have attempted to systematically investigate the precise attributes that constitute a preferred object and the behaviour that these objects afford. We have designed a research program to systematically study rats' motivation to interact with enrichment objects. Here we present the results from two experiments which examined the time rats spent with objects that only differed in size. This showed that rats spent longer with large objects rather than small ones, even though objects were presented individually. We also investigated the rats' behaviour with the objects in an open field and found that rats spent longer climbing on top of the large object. This behaviour continued when the large objects were laid on their sides instead of placed upright in the arena, suggesting that the rats were not simply climbing on the objects to investigate the top of the arena and thus an escape route, but instead were genuinely motivated to climb. This suggests that rat welfare could be enhanced by the addition to their cages of objects that permit climbing. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The present research sought to investigate the role of the basal ganglia in timing of sub- and supra-second intervals via an examination of the ability of people with Parkinson's disease (PD) to make temporal judgments in two ranges, 100-500 ms, and 1-5 s. Eighteen nondemented medicated patients with PD were compared with 14 matched controls on a duration-bisection task in which participants were required to discriminate auditory and visual signal durations within each time range. Results showed that patients with PD exhibited more variable duration judgments across both signal modality and duration range than controls, although closer analyses confirmed a timing deficit in the longer duration range only. The findings presented here suggest the bisection procedure may be a useful tool in identifying timing impairments in PD and, more generally, reaffirm the hypothesised role of the basal ganglia in temporal perception at the level of the attentionally mediated internal clock as well as memory retrieval and/or decision-making processes. (c) 2007 Elsevier Inc. All rights reserved.
Resumo:
Selecting a stimulus as the target for a goal-directed movement involves inhibiting other competing possible responses. Both target and distractor stimuli activate populations of neurons in topographic oculomotor maps such as the superior colliculus. Local inhibitory interconnections between these populations ensure only one saccade target is selected. Suppressing saccades to distractors may additionally involve inhibiting corresponding map regions to bias the local competition. Behavioral evidence of these inhibitory processes comes from the effects of distractors on oculomotor and manual trajectories. Individual saccades may initially deviate either toward or away from a distractor, but the source of this variability has not been investigated. Here we investigate the relation between distractor-related deviation of trajectory and saccade latency. Targets were presented with, or without, distractors, and the deviation of saccade trajectories arising from the presence of distractors was measured. A fixation gap paradigm was used to manipulate latency independently of the influence of competing distractors. Shorter- latency saccades deviated toward distractors and longer-latency saccades deviated away from distractors. The transition between deviation toward or away from distractors occurred at a saccade latency of around 200 ms. This shows that the time course of the inhibitory process involved in distractor related suppression is relatively slow.