130 resultados para Public performance of music


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The IPD Annual Index is the largest and most comprehensive Real Estate market index available in the UK Such coverage however inevitably leads to delays in publication. In contrast there are a number of quarterly and monthly indices which are published within days of the year end but which lack the coverage in terms of size and numbers of properties. This paper analyses these smaller but more timely indices to see whether such indices can be used to predict the performance of the IPD Annual Index. Using a number of measures of forecasting accuracy it is shown that the smaller indices provide unbiased and efficient predictions of the IPD Annual Index. Such indices also significantly outperform a naive no-change model. Although no one index performs significantly better than the others. The more timely indices however do not perfectly track the IPD Annual Index. As a result any short run predictions of performance will be subject to a degree of error. Nevertheless the more timely indices, although lacking authoritative coverage, provide a valuable service to investors giving good estimates of Real Estates performance well before the publication of the IPD Annual Index.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Predicting how insect crop pests will respond to global climate change is an important part of increasing crop production for future food security, and will increasingly rely on empirically based evidence. The effects of atmospheric composition, especially elevated carbon dioxide (eCO(2)), on insect herbivores have been well studied, but this research has focussed almost exclusively on aboveground insects. However, responses of root-feeding insects to eCO(2) are unlikely to mirror these trends because of fundamental differences between aboveground and belowground habitats. Moreover, changes in secondary metabolites and defensive responses to insect attack under eCO(2) conditions are largely unexplored for root herbivore interactions. This study investigated how eCO(2) (700 mu mol mol-1) affected a root-feeding herbivore via changes to plant growth and concentrations of carbon (C), nitrogen (N) and phenolics. This study used the root-feeding vine weevil, Otiorhynchus sulcatus and the perennial crop, Ribes nigrum. Weevil populations decreased by 33% and body mass decreased by 23% (from 7.2 to 5.4 mg) in eCO(2). Root biomass decreased by 16% in eCO(2), which was strongly correlated with weevil performance. While root N concentrations fell by 8%, there were no significant effects of eCO(2) on root C and N concentrations. Weevils caused a sink in plants, resulting in 8-12% decreases in leaf C concentration following herbivory. There was an interactive effect of CO(2) and root herbivory on root phenolic concentrations, whereby weevils induced an increase at ambient CO(2), suggestive of defensive response, but caused a decrease under eCO(2). Contrary to predictions, there was a positive relationship between root phenolics and weevil performance. We conclude that impaired root-growth underpinned the negative effects of eCO(2) on vine weevils and speculate that the plant's failure to mount a defensive response at eCO(2) may have intensified these negative effects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Kalpana Very High Resolution Radiometer (VHRR) water vapour (WV) channel is very similar to the WV channel of the Meteosat Visible and Infrared Radiation Imager (MVIRI) on Meteosat-7, and both satellites observe the Indian subcontinent. Thus it is possible to compare the performance of VHRR and MVIRI in numerical weather prediction (NWP) models. In order to do so, the impact of Kalpana- and Meteosat-7-measured WV radiances was evaluated using analyses and forecasts of moisture, temperature, geopotential and winds, using the European Centre for Medium-range Weather Forecasts (ECMWF) NWP model. Compared with experiments using Meteosat-7, the experiments using Kalpana WV radiances show a similar fit to all observations and produce very similar forecasts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Four blends formulated with low saturated fatty acid content, with the saturated component rich in stearic acid, were prepared from shea stearin, interesterified shea stearin, fully hardened soybean oil and high oleic sunflower oil in order to study their performance as shortenings in puff pastry products. The blends had a low saturated fatty acid content (30.1 ± 1.1%) compared to butter (65.9%). Saturates in the four blends examined came mainly from SSS, SOS, SSO and SOO. Puff pastry prepared from the blend that contained SOS as the main source of saturates had better properties than the other blends. It was similar to butter in compressibility of the baked product. The β-polymorphic form was present in all blends, although blends containing the highest levels of SSS also showed some β′ crystals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper provides a comparative study of the performance of cross-flow and counter-flow M-cycle heat exchangers for dew point cooling. It is recognised that evaporative cooling systems offer a low energy alternative to conventional air conditioning units. Recently emerged dew point cooling, as the renovated evaporative cooling configuration, is claimed to have much higher cooling output over the conventional evaporative modes owing to use of the M-cycle heat exchangers. Cross-flow and counter-flow heat exchangers, as the available structures for M-cycle dew point cooling processing, were theoretically and experimentally investigated to identify the difference in cooling effectiveness of both under the parallel structural/operational conditions, optimise the geometrical sizes of the exchangers and suggest their favourite operational conditions. Through development of a dedicated computer model and case-by-case experimental testing and validation, a parametric study of the cooling performance of the counter-flow and cross-flow heat exchangers was carried out. The results showed the counter-flow exchanger offered greater (around 20% higher) cooling capacity, as well as greater (15%–23% higher) dew-point and wet-bulb effectiveness when equal in physical size and under the same operating conditions. The cross-flow system, however, had a greater (10% higher) Energy Efficiency (COP). As the increased cooling effectiveness will lead to reduced air volume flow rate, smaller system size and lower cost, whilst the size and cost are the inherent barriers for use of dew point cooling as the alternation of the conventional cooling systems, the counter-flow system is considered to offer practical advantages over the cross-flow system that would aid the uptake of this low energy cooling alternative. In line with increased global demand for energy in cooling of building, largely by economic booming of emerging developing nations and recognised global warming, the research results will be of significant importance in terms of promoting deployment of the low energy dew point cooling system, helping reduction of energy use in cooling of buildings and cut of the associated carbon emission.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent activity in the development of future weather data for building performance simulation follows recognition of the limitations of traditional methods, which have been based on a stationary (observed) climate. In the UK, such developments have followed on from the availability of regional climate models as delivered in UKCIP02 and recently the probabilistic projections released under UKCP09. One major area of concern is the future performance and adaptability of buildings which employ exclusively passive or low-energy cooling systems. One such method which can be employed in an integral or retrofit situation is direct or indirect evaporative cooling. The effectiveness of evaporative cooling is most strongly influenced by the wet-bulb depression of the ambient air, hence is generally regarded as most suited to hot, dry climates. However, this technology has been shown to be effective in the UK, primarily in mixed-mode buildings or as a retrofit to industrial/commercial applications. Climate projections for the UK generally indicate an increase in the summer wet-bulb depression, suggesting an enhanced potential for the application of evaporative cooling. The paper illustrates this potential by an analysis of the probabilistic scenarios released under UKCP09, together with a detailed building/plant simulation of case study building located in the South-East of England. The results indicate a high probability that evaporative cooling will still be a viable low-energy technique in the 2050s.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

James Cooksey Culwick (1845-1907) was born in England. Trained as chorister and organist in Lichfield Cathedral, he moved to Ireland at twenty- one and remained until his death in 1907. Although his reputation as scholar, musician and teacher was acknowledged widely during his lifetime - he received an honorary doctorate from University of Dublin (1893) - little is known about the contribution he made to music education. This paper addresses this gap in the literature and argues that it was Culwick's singular achievement to pay attention to music pedagogy at secondary level, by recognizing that music could be seen as a serious career option for girls, and by providing resources for teachers which emphasised the development of an 'art-feeling' in pupils of all abilities. In addition, he considered Irish music as an art which had significance as music first, and Irish music second, and advocated a 'laudable tolerance' for opposing views on matters of cultural identity to Ireland at the end of the nineteenth century.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper evaluates the extent to which the performance of English Premier League football club managers can be attributed to skill or luck when measured separately from the characteristics of the team. We first use a specification that models managerial skill as a fixed effect and we examine the relationship between the number of points earned in league matches and the club’s wage bill, transfer spending, and the extent to which they were hit by absent players through injuries, suspensions or unavailability. We next implement a bootstrapping approach to generate a simulated distribution of average points that could have taken place after the impact of the manager has been removed. The findings suggest that there are a considerable number of highly skilled managers but also several who perform below expectations. The paper proceeds to illustrate how the approach adopted could be used to determine the optimal time for a club to part company with its manager. We are able to identify in advance several managers who the analysis suggests could have been fired earlier and others whose sackings were hard to justify based on their performances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The heat pump market in the UK has grown rapidly over the last few years. Performance analyses of vertical ground-loop heat exchanger configurations have been widely carried out using both numerical modelling and experiments. However, research findings and design recommendations on horizontal slinky-loop and vertical slinky-loop heat exchangers are far fewer compared with those for vertical ground-loop heat exchanger configurations, especially where the long-term operation of the systems is concerned. The paper presents the results obtained from a numerical simulation for the horizontal slinky-loop and vertical slinky-loop heat exchangers of a ground-source heat pump system. A three-dimensional numerical heat transfer model was developed to study the thermal performance of various heat exchanger configurations. The influence of the loop pitch (loop spacing) and the depth of a vertical slinky-loop installation were investigated and the thermal performance and excavation work required for the horizontal and vertical slinky-loop heat exchangers were compared. The influence of the installation depth for vertical slinky-loop configurations was also investigated. The results of this study show that the influence of the installation depth of the vertical slinky-loop heat exchanger on the thermal performance of the system is small. The maximum difference in the thermal performance between the vertical and horizontal slinky-loop heat exchangers with the same loop diameter and loop pitch is less than 5%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents results obtained from a numerical simulation for the horizontal slinky-loop heat exchanger of a ground-source heat pump system. A three-dimensional numerical model was developed and the results of the thermal performance of various heat exchanger configurations are presented. The investigation was carried out on five types of loop pitch (loop spacing), three types of loop diameter, three values of soil thermal properties, and allowing continuous and intermittent operation. Comparison was made for the heat transfer rate, the amount of pipe material needed, as well as excavation work required for the horizontal slinky-loop heat exchanger. The results indicate that system parameters have a significant effect on the thermal performance of the system

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Heating, ventilation, air conditioning and refrigeration (HVAC&R) systems account for more than 60% of the energy consumption of buildings in the UK. However, the effect of the variety of HVAC&R systems on building energy performance has not yet been taken into account within the existing building energy benchmarks. In addition, the existing building energy benchmarks are not able to assist decision-makers with HVAC&R system selection. This study attempts to overcome these two deficiencies through the performance characterisation of 36 HVAC&R systems based on the simultaneous dynamic simulation of a building and a variety of HVAC&R systems using TRNSYS software. To characterise the performance of HVAC&R systems, four criteria are considered; energy consumption, CO2 emissions, thermal comfort and indoor air quality. The results of the simulations show that, all the studied systems are able to provide an acceptable level of indoor air quality and thermal comfort. However, the energy consumption and amount of CO2 emissions vary. One of the significant outcomes of this study reveals that combined heating, cooling and power systems (CCHP) have the highest energy consumption with the lowest energy related CO2 emissions among the studied HVAC&R systems.