153 resultados para Microwave measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In its periodic declarations of domestic support to the WTO, the EU has progressively reduced its amber-box declarations in line with its changing system of farm support. Surprisingly, however, in 2007/08 it managed to more than halve its amber box compared with that of the previous year, easily achieving the reduction targets being touted in the Doha Round. This was largely due to a change in the calculations for fresh fruits and vegetables. These had been linked to the entry price system, which was not affected by the 2008 fruit and vegetables reform. Why the EU chose to make this change during the ongoing Doha Round negotiations remains unclear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical characteristics of stirred curd were simultaneously monitored during syneresis in a 10-L cheese vat using computer vision and colorimetric measurements. Curd syneresis kinetic conditions were varied using 2 levels of milk pH (6.0 and 6.5) and 2 agitation speeds (12.1 and 27.2 rpm). Measured optical parameters were compared with gravimetric measurements of syneresis, taken simultaneously. The results showed that computer vision and colorimeter measurements have potential for monitoring syneresis. The 2 different phases, curd and whey, were distinguished by means of color differences. As syneresis progressed, the backscattered light became increasingly yellow in hue for circa 20 min for the higher stirring speed and circa 30 min for the lower stirring speed. Syneresis-related gravimetric measurements of importance to cheese making (e.g., curd moisture content, total solids in whey, and yield of whey) correlated significantly with computer vision and colorimetric measurements..

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2007, the Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF) was operated for a nine-month period in the Murg Valley, Black Forest, Germany, in support of the Convective and Orographically-induced Precipitation Study (COPS). The synergy of AMF and COPS partner instrumentation was exploited to derive a set of high-quality thermodynamic and cloud property profiles with 30 s resolution. In total, clouds were present 72% of the time, with multi-layer mixed phase (28.4%) and single-layer water clouds (11.3%) occurring most frequently. A comparison with the Cloudnet sites Chilbolton and Lindenberg for the same time period revealed that the Murg Valley exhibits lower liquid water paths (LWPs; median = 37.5 g m−2) compared to the two sites located in flat terrain. In order to evaluate the derived thermodynamic and cloud property profiles, a radiative closure study was performed with independent surface radiation measurements. In clear sky, average differences between calculated and observed surface fluxes are less than 2% and 4% for the short wave and long wave part, respectively. In cloudy situations, differences between simulated and observed fluxes, particularly in the short wave part, are much larger, but most of these can be related to broken cloud situations. The daytime cloud radiative effect (CRE), i.e. the difference of cloudy and clear-sky net fluxes, has been analysed for the whole nine-month period. For overcast, single-layer water clouds, sensitivity studies revealed that the CRE uncertainty is likewise determined by uncertainties in liquid water content and effective radius. For low LWP clouds, CRE uncertainty is dominated by LWP uncertainty; therefore refined retrievals, such as using infrared and/or higher microwave frequencies, are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes advances in ground-based thermodynamic profiling of the lower troposphere through sensor synergy. The well-documented integrated profiling technique (IPT), which uses a microwave profiler, a cloud radar, and a ceilometer to simultaneously retrieve vertical profiles of temperature, humidity, and liquid water content (LWC) of nonprecipitating clouds, is further developed toward an enhanced performance in the boundary layer and lower troposphere. For a more accurate temperature profile, this is accomplished by including an elevation scanning measurement modus of the microwave profiler. Height-dependent RMS accuracies of temperature (humidity) ranging from 0.3 to 0.9 K (0.5–0.8 g m−3) in the boundary layer are derived from retrieval simulations and confirmed experimentally with measurements at distinct heights taken during the 2005 International Lindenberg Campaign for Assessment of Humidity and Cloud Profiling Systems and its Impact on High-Resolution Modeling (LAUNCH) of the German Weather Service. Temperature inversions, especially of the lower boundary layer, are captured in a very satisfactory way by using the elevation scanning mode. To improve the quality of liquid water content measurements in clouds the authors incorporate a sophisticated target classification scheme developed within the European cloud observing network CloudNet. It allows the detailed discrimination between different types of backscatterers detected by cloud radar and ceilometer. Finally, to allow IPT application also to drizzling cases, an LWC profiling method is integrated. This technique classifies the detected hydrometeors into three different size classes using certain thresholds determined by radar reflectivity and/or ceilometer extinction profiles. By inclusion into IPT, the retrieved profiles are made consistent with the measurements of the microwave profiler and an LWC a priori profile. Results of IPT application to 13 days of the LAUNCH campaign are analyzed, and the importance of integrated profiling for model evaluation is underlined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We introduce the notion that the energy of individuals can manifest as a higher-level, collective construct. To this end, we conducted four independent studies to investigate the viability and importance of the collective energy construct as assessed by a new survey instrument—the productive energy measure (PEM). Study 1 (n = 2208) included exploratory and confirmatory factor analyses to explore the underlying factor structure of PEM. Study 2 (n = 660) cross-validated the same factor structure in an independent sample. In study 3, we administered the PEM to more than 5000 employees from 145 departments located in five countries. Results from measurement invariance, statistical aggregation, convergent, and discriminant-validity assessments offered additional support for the construct validity of PEM. In terms of predictive and incremental validity, the PEM was positively associated with three collective attitudes—units' commitment to goals, the organization, and overall satisfaction. In study 4, we explored the relationship between the productive energy of firms and their overall performance. Using data from 92 firms (n = 5939employees), we found a positive relationship between the PEM (aggregated to the firm level) and the performance of those firms. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estimating snow mass at continental scales is difficult, but important for understanding land-atmosphere interactions, biogeochemical cycles and the hydrology of the Northern latitudes. Remote sensing provides the only consistent global observations, butwith unknown errors. Wetest the theoretical performance of the Chang algorithm for estimating snow mass from passive microwave measurements using the Helsinki University of Technology (HUT) snow microwave emission model. The algorithm's dependence upon assumptions of fixed and uniform snow density and grainsize is determined, and measurements of these properties made at the Cold Land Processes Experiment (CLPX) Colorado field site in 2002–2003 used to quantify the retrieval errors caused by differences between the algorithm assumptions and measurements. Deviation from the Chang algorithm snow density and grainsize assumptions gives rise to an error of a factor of between two and three in calculating snow mass. The possibility that the algorithm performsmore accurately over large areas than at points is tested by simulating emission from a 25 km diameter area of snow with a distribution of properties derived from the snow pitmeasurements, using the Chang algorithm to calculate mean snow-mass from the simulated emission. The snowmass estimation froma site exhibiting the heterogeneity of the CLPX Colorado site proves onlymarginally different than that from a similarly-simulated homogeneous site. The estimation accuracy predictions are tested using the CLPX field measurements of snow mass, and simultaneous SSM/I and AMSR-E measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although there is a large body of research on brand equity, little in terms of a literature review has been published on this since Feldwick's (1996) paper. To address this gap, this paper brings together the scattered literature on consumer-based brand equity's conceptualisation and measurement. Measures of consumer-based brand equity are classified as either direct or indirect. Indirect measures assess consumer-based brand equity through its demonstrable dimensions and are superior from a diagnostic level. The paper concludes with directions for future research and managerial pointers for setting up a brand equity measurement system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concentrations of five esters of p-hydroxybenzoic acid (parabens) were measured using HPLC-MS/MS at four serial locations across the human breast from axilla to sternum using human breast tissue collected from 40 mastectomies for primary breast cancer in England between 2005 and 2008. One or more paraben esters were quantifiable in 158/160 (99%) of the tissue samples and in 96/160 (60%) all five esters were measured. Variation was notable with respect to individual paraben esters, location within one breast and similar locations in different breasts. Overall median values in nanograms per gram tissue for the 160 tissue samples were highest for n-propylparaben [16.8 (range 0–2052.7)] and methylparaben [16.6 (range 0–5102.9)]; levels were lower for n-butylparaben [5.8 (range 0–95.4)], ethylparaben [3.4 (range 0–499.7)] and isobutylparaben 2.1 (range 0–802.9). The overall median value for total paraben was 85.5 ng g−1 tissue (range 0–5134.5). The source of the paraben cannot be identified, but paraben was measured in the 7/40 patients who reported never having used underarm cosmetics in their lifetime. No correlations were found between paraben concentrations and age of patient (37–91 years), length of breast feeding (0–23 months), tumour location or tumour oestrogen receptor content. In view of the disproportionate incidence of breast cancer in the upper outer quadrant, paraben concentrations were compared across the four regions of the breast: n-propylparaben was found at significantly higher levels in the axilla than mid (P = 0.004 Wilcoxon matched pairs) or medial (P = 0.021 Wilcoxon matched pairs) regions (P = 0.010 Friedman ANOVA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been found that hydrogels may be formed by microwave irradiation of aqueous solutions containing appropriate combinations of polymers. This new method of hydrogel synthesis yields sterile hydrogels without the use of monomers, eliminating the need for the removal of unreacted species from the final product. Results for two particularly successful combinations, poly(vinyl alcohol) with either poly(acrylic acid) or poly(methylvinylether-alt-maleic anhydride), are presented. Irradiation using temperatures of 100–150 °C was found to yield hydrogels with large equilibrium swelling degrees of 500–1000 g g−1. Material leached from both types of hydrogel shows little cytotoxicity towards HT29 cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Procedures for obtaining molecular orientational parameters from wide angle X-ray scattering patterns of samples of thermotropic liquid crystalline polymers are presented. The methods described are applied to an extrusion-aligned sample of a random copolyester of poly(ethylene terephthalate) (PET) and p-acetoxybenzoic acid. Values of the orientational parameters are obtained from both the interchain and intrachain maxima in the scattering pattern. The differences in the values so derived suggest some level of local rotational correlation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measuring the retention, or residence time, of dosage forms to biological tissue is commonly a qualitative measurement, where no real values to describe the retention can be recorded. The result of this is an assessment that is dependent upon a user's interpretation of visual observation. This research paper outlines the development of a methodology to quantitatively measure, both by image analysis and by spectrophotometric techniques, the retention of material to biological tissues, using the retention of polymer solutions to ocular tissue as an example. Both methods have been shown to be repeatable, with the spectrophotometric measurement generating data reliably and quickly for further analysis.