146 resultados para Building energy simulations


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present simulations of London's meteorology using the Met Office Unified Model with a new, sophisticated surface energy-balance scheme to represent the urban surfaces, called MORUSES. Simulations are performed with the urban surfaces represented and with the urban surfaces replaced with grass in order to calculate the urban increment on the local meteorology. The local urban effects were moderated to some extent by the passage of an onshore flow that propagated up the Thames estuary and across the city, cooling London slightly in the afternoon. Validations of screen-level temperature show encouraging agreement to within 1–2 K, when the urban increment is up to 5 K. The model results are then used to examine factors shaping the spatial and temporal structure of London's atmospheric boundary layer. The simulations reconcile the differences in the temporal evolution of the urban heat island (UHI) shown in various studies and demonstrate that the variation of UHI with time depends strongly on the urban fetch. The UHI at a location downwind of the city centre shows a decrease in UHI during the night, while the UHI at the city centre stays constant. Finally, the UHI at a location upwind of the city centre increases continuously. The magnitude of the UHI by the time of the evening transition increases with urban fetch. The urban increments are largest at night, when the boundary layer is shallow. The boundary layer experiences continued warming after sunset, as the heat from the urban fabric is released, and a weakly convective boundary layer develops across the city. The urban land-use fraction is the dominant control on the spatial structure in the sensible heat flux and the resulting urban increment, although even the weak advection present in this case study is sufficient to advect the peak temperature increments downwind of the most built-up areas. Copyright © 2011 Royal Meteorological Society and British Crown Copyright, the Met Office

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates whether obtaining sustainable building certification entails a rental premium for commercial office buildings and tracks its development over time. To this aim, both a difference-in-differences and a fixed-effects model approach are applied to a large panel dataset of office buildings in the United States in the 2000–2010 period. The results indicate a significant rental premium for both ENERGY STAR and LEED certified buildings. Controlling for confounding factors, this premium is shown to have increased steadily from 2006 to 2008, followed by a moderate decline in the subsequent periods. The results also show a significant positive relationship between ENERGY STAR labeling and building occupancy rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The peak congestion of the European grid may create significant impacts on system costs because of the need for higher marginal cost generation, higher cost system balancing and increasing grid reinforcement investment. The use of time of use rates, incentives, real time pricing and other programmes, usually defined as Demand Side Management (DSM), could bring about significant reductions in prices, limit carbon emissions from dirty power plants, and improve the integration of renewable sources of energy. Unlike previous studies on elasticity of residential electricity demand under flat tariffs, the aim of this study is not to investigate the known relatively inelastic relationship between demand and prices. Rather, the aim is to assess how occupancy levels vary in different European countries. This reflects the reality of demand loads, which are predominantly determined by the timing of human activities (e.g. travelling to work, taking children to school) rather than prices. To this end, two types of occupancy elasticity are estimated: baseline occupancy elasticity and peak occupancy elasticity. These represent the intrinsic elasticity associated with human activities of single residential end-users in 15 European countries. This study makes use of occupancy time-series data from the Harmonised European Time Use Survey database to build European occupancy curves; identify peak occupancy periods; draw time use demand curves for video and TV watching activity; and estimate national occupancy elasticity levels of single-occupant households. Findings on occupancy elasticities provide an indication of possible DSM strategies based on occupancy levels and not prices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study presents the findings of applying a Discrete Demand Side Control (DDSC) approach to the space heating of two case study buildings. High and low tolerance scenarios are implemented on the space heating controller to assess the impact of DDSC upon buildings with different thermal capacitances, light-weight and heavy-weight construction. Space heating is provided by an electric heat pump powered from a wind turbine, with a back-up electrical network connection in the event of insufficient wind being available when a demand occurs. Findings highlight that thermal comfort is maintained within an acceptable range while the DDSC controller maintains the demand/supply balance. Whilst it is noted that energy demand increases slightly, as this is mostly supplied from the wind turbine, this is of little significance and hence a reduction in operating costs and carbon emissions is still attained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and aims CCAAT/enhancer-binding protein alpha (CEBPA) is a transcription factor involved in adipogenesis and energy homeostasis. Caloric restriction reduces CEBPA protein expression in patients with metabolic syndrome (MetS). A previous report linked rs12691 SNP in CEBPA to altered concentration of fasting triglycerides. Our objective was to assess the effects of rs12691 in glucose metabolism in Metabolic Syndrome (MetS) patients. Methods and results Glucose metabolism was assessed by static (glucose, insulin, adiponectin, leptin and resistin plasma concentrations) and dynamic (disposition index, insulin sensitivity index, HOMA-IR and acute insulin response to glucose) indices, performed at baseline and after 12 weeks of 4 dietary interventions (high saturated fatty acid (SFA), high monounsaturated fatty acid (MUFA), low-fat and low-fat-high-n3 polyunsaturated fatty acid (PUFA)) in 486 subjects with MetS. Carriers of the minor A allele of rs12691 had altered disposition index (p = 0.0003), lower acute insulin response (p = 0.005) and a lower insulin sensitivity index (p = 0.025) indicating a lower insulin sensitivity and a lower insulin secretion, at baseline and at the end of the diets. Furthermore, A allele carriers displayed lower HDL concentration. Conclusion The presence of the A allele of rs12691 influences glucose metabolism of MetS patients. Clinical Trials Registry number NCT00429195.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are varieties of physical and behavioral factors to determine energy demand load profile. The attainment of the optimum mix of measures and renewable energy system deployment requires a simple method suitable for using at the early design stage. A simple method of formulating load profile (SMLP) for UK domestic buildings has been presented in this paper. Domestic space heating load profile for different types of houses have been produced using thermal dynamic model which has been developed using thermal resistant network method. The daily breakdown energy demand load profile of appliance, domestic hot water and space heating can be predicted using this method. The method can produce daily load profile from individual house to urban community. It is suitable to be used at Renewable energy system strategic design stage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Demands for thermal comfort, better indoor air quality together with lower environmental impacts have had ascending trends in the last decade. In many circumstances, these demands could not be fully covered through the soft approach of bioclimatic design like optimisation of the building orientation and internal layout. This is mostly because of the dense urban environment and building internal energy loads. In such cases, heating, ventilation, air-conditioning and refrigeration (HVAC&R) systems make a key role to fulfill the requirements of indoor environment. Therefore, it is required to select the most proper HVAC&R system. In this study, a robust decision making approach for HVAC&R system selection is proposed. Technical performance, economic aspect and environmental impacts of 36 permutations of primary and secondary systems are taken into account to choose the most proper HVAC&R system for a case study office building. The building is a representative for the dominant form of office buildings in the UK. Dynamic performance evaluation of HVAC&R alternatives using TRNSYS package together with life cycle energy cost analysis provides a reliable basis for decision making. Six scenarios broadly cover the decision makers' attitudes on HVAC&R system selection which are analysed through Analytical Hierarchy Process (AHP). One of the significant outcomes reveals that, despite both the higher energy demand and more investment requirements associated with compound heating, cooling and power system (CCHP); this system is one of the top ranked alternatives due to the lower energy cost and C02 emissions. The sensitivity analysis reveals that in all six scenarios, the first five top ranked alternatives are not changed. Finally, the proposed approach and the results could be used by researchers and designers especially in the early stages of a design process in which all involved bodies face the lack of time, information and tools for evaluation of a variety of systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To fully appreciate the environmental impact of a workplace the transport-related carbon dioxide (CO2) emissions resulting from its location should be considered in addition to the emissions that result from the occupation of the building itself. Since the first one was built in the early 1980s, business parks have become a significant workplace location for service-sector workers; a sector of the economy that grew rapidly at that time as the UK manufacturing output declined and the employment base shifted to retail services and de-regulated financial services. This paper examines the transport-related CO2 emissions associated with these workplace locations in comparison to town and city centre locations. Using 2001 Census Special Workplace Statistics which record people’s residence, usual workplace and mode of transport between them, distance travelled and mode of travel were calculated for a sample of city centre and out-of-town office locations. The results reveal the extent of the difference between transport-related CO2 emitted by commuters to out-of-town and city centre locations. The implications that these findings have for monitoring the environmental performance of workplaces are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the first part of this article, we introduced a new urban surface scheme, the Met Office – Reading Urban Surface Exchange Scheme (MORUSES), into the Met Office Unified Model (MetUM) and compared its impact on the surface fluxes with respect to the current urban scheme. In this second part, we aim to analyze further the reasons behind the differences. This analysis is conducted by a comparison of the performance of the two schemes against observations and against a third model, the Single Column Reading Urban model (SCRUM). The key differences between the three models lie in how each model incorporates the heat stored in the urban fabric and how the surface-energy balance is coupled to the underlying substrate. The comparison of the models with observations from Mexico City reveals that the performance of MORUSES is improved if roof insulation is included by minimizing the roof thickness. A comparison of MORUSES and SCRUM reveals that, once insulation is included within MORUSES, these two models perform equally well against the observations overall, but that there are differences in the details of the simulations at the roof and canyon level. These differences are attributed to the different representations of the heat-storage term, specifically differences in the dominant frequencies captured by the urban canopy and substrate, between the models. These results strongly suggest a need for an urban model intercomparison exercise. Copyright © 2010 Royal Meteorological Society and Crown Copyright

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The past decade has witnessed a sharp increase in published research on energy and buildings. This paper takes stock of work in this area, with a particular focus on construction research and the analysis of non-technical dimensions. While there is widespread recognition as to the importance of non-technical dimensions, research tends to be limited to individualistic studies of occupants and occupant behavior. In contrast, publications in the mainstream social science literature display a broader range of interests, including policy developments, structural constraints on the diffusion and use of new technologies and the construction process itself. The growing interest of more generalist scholars in energy and buildings provides an opportunity for construction research to engage a wider audience. This would enrich the current research agenda, helping to address unanswered problems concerning the relatively weak impact of policy mechanisms and new technologies and the seeming recalcitrance of occupants. It would also help to promote the academic status of construction research as a field. This, in turn, depends on greater engagement with interpretivist types of analysis and theory building, thereby challenging deeply ingrained views on the nature and role of academic research in construction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describe a simulation program, which uses Trengenza’s average room illuminance method in conjunction with hourly solar irradiance and luminous efficacy, to predict the potential lighting energy saving for a side-lit room. Two lighting control algorithms of photoelectric switching (on/off) and photoelectric dimming (top-up) have been coded in the program. A simulation for a typical UK office room has been conducted and the results show that energy saving due to the sunlight dependent on the various factors such as orientation, control methods, building depth, glazing area and shading types, etc. This simple tool can be used for estimating the potential lighting energy saving of the windows with various shading devices at the early design stage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A cloud-resolving model is modified to implement the weak temperature gradient approximation in order to simulate the interactions between tropical convection and the large-scale tropical circulation. The instantaneous domain-mean potential temperature is relaxed toward a reference profile obtained from a radiative–convective equilibrium simulation of the cloud-resolving model. For homogeneous surface conditions, the model state at equilibrium is a large-scale circulation with its descending branch in the simulated column. This is similar to the equilibrium state found in some other studies, but not all. For this model, the development of such a circulation is insensitive to the relaxation profile and the initial conditions. Two columns of the cloud-resolving model are fully coupled by relaxing the instantaneous domain-mean potential temperature in both columns toward each other. This configuration is energetically closed in contrast to the reference-column configuration. No mean large-scale circulation develops over homogeneous surface conditions, regardless of the relative area of the two columns. The sensitivity to nonuniform surface conditions is similar to that obtained in the reference-column configuration if the two simulated columns have very different areas, but it is markedly weaker for columns of comparable area. The weaker sensitivity can be understood as being a consequence of a formulation for which the energy budget is closed. The reference-column configuration has been used to study the convection in a local region under the influence of a large-scale circulation. The extension to a two-column configuration is proposed as a methodology for studying the influence on local convection of changes in remote convection.