120 resultados para Robot arm


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Robot-mediated neurorehabilitation is a rapidly advancing field that seeks to use advances in robotics, virtual realities, and haptic interfaces, coupled with theories in neuroscience and rehabilitation to define new methods for treating neurological injuries such as stroke, spinal cord injury, and traumatic brain injury. The field is nascent and much work is needed to identify efficient hardware, software, and control system designs alongside the most effective methods for delivering treatment in home and hospital settings. This paper identifies the need for robots in neurorehabilitation and identifies important goals that will allow this field to advance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Movement disorders (MD) include a group of neurological disorders that involve neuromotor systems. MD can result in several abnormalities ranging from an inability to move, to severe constant and excessive movements. Strokes are a leading cause of disability affecting largely the older people worldwide. Traditional treatments rely on the use of physiotherapy that is partially based on theories and also heavily reliant on the therapists training and past experience. The lack of evidence to prove that one treatment is more effective than any other makes the rehabilitation of stroke patients a difficult task. UL motor re-learning and recovery levels tend to improve with intensive physiotherapy delivery. The need for conclusive evidence supporting one method over the other and the need to stimulate the stroke patient clearly suggest that traditional methods lack high motivational content, as well as objective standardised analytical methods for evaluating a patient's performance and assessment of therapy effectiveness. Despite all the advances in machine mediated therapies, there is still a need to improve therapy tools. This chapter describes a new approach to robot assisted neuro-rehabilitation for upper limb rehabilitation. Gentle/S introduces a new approach on the integration of appropriate haptic technologies to high quality virtual environments, so as to deliver challenging and meaningful therapies to people with upper limb impairment in consequence of a stroke. The described approach can enhance traditional therapy tools, provide therapy "on demand" and can present accurate objective measurements of a patient's progression. Our recent studies suggest the use of tele-presence and VR-based systems can potentially motivate patients to exercise for longer periods of time. Two identical prototypes have undergone extended clinical trials in the UK and Ireland with a cohort of 30 stroke subjects. From the lessons learnt with the Gentle/S approach, it is clear also that high quality therapy devices of this nature have a role in future delivery of stroke rehabilitation, and machine mediated therapies should be available to patient and his/her clinical team from initial hospital admission, through to long term placement in the patient's home following hospital discharge.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new strategy for controlling rigid-robot manipulators in the presence of parametric uncertainties or un-modelled dynamics. The strategy combines an adaptation law with a well known robust controller proposed by Spong, which is derived using Lyapunov's direct method. Although the tracking problem of manipulators has been successfully solved with different strategies, there are some conditions under which their efficiency is limited. Specifically, their performance decreases when unknown loading masses or model disturbances are introduced. The aim of this work is to show that the proposed strategy performs better than existing algorithms, as verified with real-time experimental results with a Puma-560 robot. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rodney Brooks has been called the “Self Styled Bad Boy of Robotics”. In the 1990s he gained this dubious honour by orchestrating a string of highly evocative robots from his artificial interligence Labs at the Massachusettes Institute of Technology (MIT), Boston, USA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ARM Shortwave Spectrometer (SWS) measures zenith radiance at 418 wavelengths between 350 and 2170 nm. Because of its 1-sec sampling resolution, the SWS provides a unique capability to study the transition zone between cloudy and clear sky areas. A spectral invariant behavior is found between ratios of zenith radiance spectra during the transition from cloudy to cloud-free. This behavior suggests that the spectral signature of the transition zone is a linear mixture between the two extremes (definitely cloudy and definitely clear). The weighting function of the linear mixture is a wavelength-independent characteristic of the transition zone. It is shown that the transition zone spectrum is fully determined by this function and zenith radiance spectra of clear and cloudy regions. An important result of these discoveries is that high temporal resolution radiance measurements in the clear-to-cloud transition zone can be well approximated by lower temporal resolution measurements plus linear interpolation.