68 resultados para Reconfiguration of distribution systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper aims to assess the necessity of updating the intensity-duration-frequency (IDF) curves used in Portugal to design building storm-water drainage systems. A comparative analysis of the design was performed for the three predefined rainfall regions in Portugal using the IDF curves currently in use and estimated for future decades. Data for recent and future climate conditions simulated by a global and regional climate model chain are used to estimate possible changes of rainfall extremes and its implications for the drainage systems. The methodology includes the disaggregation of precipitation up to subhourly scales, the robust development of IDF curves, and the correction of model bias. Obtained results indicate that projected changes are largest for the plains in southern Portugal (5–33%) than for mountainous regions (3–9%) and that these trends are consistent with projected changes in the long-term 95th percentile of the daily precipitation throughout the 21st century. The authors conclude there is a need to review the current precipitation regime classification and change the new drainage systems towards larger dimensions to mitigate the projected changes in extreme precipitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To mitigate the inter-carrier interference (ICI) of doubly-selective (DS) fading channels, we consider a hybrid carrier modulation (HCM) system employing the discrete partial fast Fourier transform (DPFFT) demodulation and the banded minimum mean square error (MMSE) equalization in this letter. We first provide the discrete form of partial FFT demodulation, then apply the banded MMSE equalization to suppress the residual interference at the receiver. The proposed algorithm has been demonstrated, via numerical simulations, to be its superior over the single carrier modulation (SCM) system and circularly prefixed orthogonal frequency division multiplexing (OFDM) system over a typical DS channel. Moreover, it represents a good trade-off between computational complexity and performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Implicit dynamic-algebraic equations, known in control theory as descriptor systems, arise naturally in many applications. Such systems may not be regular (often referred to as singular). In that case the equations may not have unique solutions for consistent initial conditions and arbitrary inputs and the system may not be controllable or observable. Many control systems can be regularized by proportional and/or derivative feedback.We present an overview of mathematical theory and numerical techniques for regularizing descriptor systems using feedback controls. The aim is to provide stable numerical techniques for analyzing and constructing regular control and state estimation systems and for ensuring that these systems are robust. State and output feedback designs for regularizing linear time-invariant systems are described, including methods for disturbance decoupling and mixed output problems. Extensions of these techniques to time-varying linear and nonlinear systems are discussed in the final section.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The method of distributing the outdoor air in classrooms has a major impact on indoor air quality and thermal comfort of pupils. In a previous study, ([11] Karimipanah T, Sandberg M, Awbi HB. A comparative study of different air distribution systems in a classroom. In: Proceedings of Roomvent 2000, vol. II, Reading, UK, 2000. p. 1013-18; [13] Karimipanah T, Sandberg M, Awbi HB, Blomqvist C. Effectiveness of confluent jets ventilation system for classrooms. In: Idoor Air 2005, Beijing, China, 2005 (to be presented).) presented results for four and two types of air distribution systems tested in a purpose built classroom with simulated occupancy as well as computational fluid dynamics (CFD) modelling. In this paper, the same experimental setup has been used to investigate the indoor environment in the classroom using confluent jet ventilation, see also ([12]Cho YJ, Awbi HB, Karimipanah T. The characteristics of wall confluent jets for ventilated enclosures. In: Proceedings of Roomvent 2004, Coimbra, Portugal, 2004.) Measurements of air speed, air temperature and tracer gas concentrations have been carried out for different thermal conditions. In addition, 56 cases of CFD simulations have been carried to provide additional information on the indoor air quality and comfort conditions throughout the classroom, such as ventilation effectiveness, air exchange effectiveness, effect of flow rate, effect of radiation, effect of supply temperature, etc., and these are compared with measured data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An investigation into the speciation and occurrence of nine haloacetic acids (HAAs) was conducted during the period of April 2007 to March 2008 and involved three drinking water supply systems in England, which were chosen to represent a range of source water conditions; these were an upland surface water, a lowland surface water and a groundwater. Samples were collected seasonally from the water treatment plants and at different locations in the distribution systems. The highest HAA concentrations occurred in the upland surface water system, with an average total HAA concentration of 21.3 μg/L. The lowest HAA levels were observed in the groundwater source, with a mean concentration of 0.6 μg/L. Seasonal variations were significant in the HAA concentrations; the highest total HAA concentrations were found during the autumn, when the concentrations were approximately two times higher than in winter and spring. HAA speciation varied among the water sources, with dichloroacetic acid and trichloroacetic acid dominant in the lowland surface water system and brominated species dominant in the upland surface water system. There was a strong correlation between trihalomethanes and HAAs when considering all samples from the three systems in the same data set (r2=0.88); however, the correlation was poor/moderate when considering each system independently.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper assesses the impact of the location and configuration of Battery Energy Storage Systems (BESS) on Low-Voltage (LV) feeders. BESS are now being deployed on LV networks by Distribution Network Operators (DNOs) as an alternative to conventional reinforcement (e.g. upgrading cables and transformers) in response to increased electricity demand from new technologies such as electric vehicles. By storing energy during periods of low demand and then releasing that energy at times of high demand, the peak demand of a given LV substation on the grid can be reduced therefore mitigating or at least delaying the need for replacement and upgrade. However, existing research into this application of BESS tends to evaluate the aggregated impact of such systems at the substation level and does not systematically consider the impact of the location and configuration of BESS on the voltage profiles, losses and utilisation within a given feeder. In this paper, four configurations of BESS are considered: single-phase, unlinked three-phase, linked three-phase without storage for phase-balancing only, and linked three-phase with storage. These four configurations are then assessed based on models of two real LV networks. In each case, the impact of the BESS is systematically evaluated at every node in the LV network using Matlab linked with OpenDSS. The location and configuration of a BESS is shown to be critical when seeking the best overall network impact or when considering specific impacts on voltage, losses, or utilisation separately. Furthermore, the paper also demonstrates that phase-balancing without energy storage can provide much of the gains on unbalanced networks compared to systems with energy storage.