65 resultados para COSMIC GAMMA SOURCES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three strains of a gram-negative, blood or serum requiring, rod-shaped bacterium recovered from human clinical specimens were characterised by phenotypic and molecular taxonomic methods. Comparative 16S rRNA gene sequencing showed the unknown rod-shaped strains are members of the same species as some fastidious isolates recovered from human blood specimens and previously designated "Leptotrichia sanguinegens". Based on phylogenetic and phenotypic evidence, it is proposed that the isolates from human sources be classified in a new genus Sneathia, as Sneathia sanguinegens gen. nov., sp. nov. The type strain of Sneathia sanguinegens is CCUG 41628T.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two vertical cosmic ray telescopes for atmospheric cosmic ray ionization event detection are compared. Counter A, designed for low power remote use, was deployed in the Welsh mountains; its event rate increased with altitude as expected from atmospheric cosmic ray absorption. Independently, Counter B’s event rate was found to vary with incoming particle acceptance angle. Simultaneous colocated comparison of both telescopes exposed to atmospheric ionization showed a linear relationship between their event rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

*** Purpose – Computer tomography (CT) for 3D reconstruction entails a huge number of coplanar fan-beam projections for each of a large number of 2D slice images, and excessive radiation intensities and dosages. For some applications its rate of throughput is also inadequate. A technique for overcoming these limitations is outlined. *** Design methodology/approach – A novel method to reconstruct 3D surface models of objects is presented, using, typically, ten, 2D projective images. These images are generated by relative motion between this set of objects and a set of ten fanbeam X-ray sources and sensors, with their viewing axes suitably distributed in 2D angular space. *** Findings – The method entails a radiation dosage several orders of magnitude lower than CT, and requires far less computational power. Experimental results are given to illustrate the capability of the technique *** Practical implications – The substantially lower cost of the method and, more particularly, its dramatically lower irradiation make it relevant to many applications precluded by current techniques *** Originality/value – The method can be used in many applications such as aircraft hold-luggage screening, 3D industrial modelling and measurement, and it should also have important applications to medical diagnosis and surgery.