93 resultados para evaluative conditioning


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A two-level fuzzy logic controller for use in air-conditioning systems is outlined in this paper. At the first level a simplified controller is produced from expert knowledge and envelope adjustment is introduced, while the second level provides a means for adapting this controller to different working spaces. The mechanism for adaption is easily implemented and can be used in real time. A series of simulations is presented to illustrate the proposed schema.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accumulating data suggest that diets rich in flavanols and procyanidins are beneficial for human health. In this context, there has been a great interest in elucidating the systemic levels and metabolic profiles at which these compounds occur in humans. While recent progress has been made, there still exist considerable differences and various disagreements with regard to the mammalian metabolites of these compounds, which in turn is largely a consequence of the lack of availability of authentic standards that would allow for the directed development and validation of expedient analytical methodologies. In the present study, we developed a method for the analysis of structurally-related flavanol metabolites using a wide range of authentic standards. Applying this method in the context of a human dietary intervention study using comprehensively characterized and standardized flavanol- and procyanidin-containing cocoa, we were able to identify the structurally-related (−)-epicatechin metabolites (SREM) postprandially extant in the systemic circulation of humans. Our results demonstrate that (−)-epicatechin-3′-β-D-glucuronide, (−)-epicatechin-3′-sulfate, and a 3′-O-methyl(−)-epicatechin-5/7-sulfate are the predominant SREM in humans, and further confirm the relevance of the stereochemical configuration in the context of flavanol metabolism. In addition, we also identified plausible causes for the previously reported discrepancies regarding flavanol metabolism, consisting to a significant extent of inter-laboratory differences in sample preparation (enzymatic treatment and sample conditioning for HPLC analysis) and detection systems. Thus, these findings may also aid in the establishment of consensus on this topic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In 2003 the European Commission started using Impact Assessment (IA) as the main empirical basis for its major policy proposals. The aim was to systematically assess ex ante the economic, social and environmental impacts of EU policy proposals. In parallel, research proliferated in search for theoretical grounds for IAs and in an attempt to evaluate empirically the performance of the first sets of IAs produced by the European Commission. This paper combines conceptual and evaluative studies carried out in the first five years of EU IAs. It concludes that the great discrepancy between rationale and practice calls for a different theoretical focus and a higher emphasis on evaluating empirically crucial risk economics aspects of IAs, such as the value of statistical life, price of carbon, the integration of macroeconomic modelling and scenario analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays utilising the proper HVAC system is essential both in extreme weather conditions and dense buildings design. Hydraulic loops are the most common parts in all air conditioning systems. This article aims to investigate the performance of different hydraulic loop arrangements in variable flow systems. Technical, economic and environmental assessments have been considered in this process. A dynamic system simulation is generated to evaluate the system performance and an economic evaluation is conducted by whole life cost assessment. Moreover, environmental impacts have been studied by considering the whole life energy consumption, CO2 emission, the embodied energy and embodied CO2 of the system components. Finally, decision-making in choosing the most suitable hydraulic system among five well-known alternatives has been proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Demands for thermal comfort, better indoor air quality together with lower environmental impacts have had ascending trends in the last decade. In many circumstances, these demands could not be fully covered through the soft approach of bioclimatic design like optimisation of the building orientation and internal layout. This is mostly because of the dense urban environment and building internal energy loads. In such cases, heating, ventilation, air-conditioning and refrigeration (HVAC&R) systems make a key role to fulfill the requirements of indoor environment. Therefore, it is required to select the most proper HVAC&R system. In this study, a robust decision making approach for HVAC&R system selection is proposed. Technical performance, economic aspect and environmental impacts of 36 permutations of primary and secondary systems are taken into account to choose the most proper HVAC&R system for a case study office building. The building is a representative for the dominant form of office buildings in the UK. Dynamic performance evaluation of HVAC&R alternatives using TRNSYS package together with life cycle energy cost analysis provides a reliable basis for decision making. Six scenarios broadly cover the decision makers' attitudes on HVAC&R system selection which are analysed through Analytical Hierarchy Process (AHP). One of the significant outcomes reveals that, despite both the higher energy demand and more investment requirements associated with compound heating, cooling and power system (CCHP); this system is one of the top ranked alternatives due to the lower energy cost and C02 emissions. The sensitivity analysis reveals that in all six scenarios, the first five top ranked alternatives are not changed. Finally, the proposed approach and the results could be used by researchers and designers especially in the early stages of a design process in which all involved bodies face the lack of time, information and tools for evaluation of a variety of systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the findings of the study that examines how income multiples for mortgage loan associates with home repossession using the data of the Council of Mortgage Lenders (CML). It employs a statistical measure for improving regression efficiency with conditioning information in the form of lagged instrument to unravel the pattern of association evident from the data. Based on the data, the study investigates what level of income multiples is optimum – that is the income multiple that minimises home repossession. A sensitivity analysis was undertaken to show how home repossession responds to changes in income multiples. For each of the analytical tasks, the study compares the aggregate market, first-time-buyers, and home movers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a nonlinear regression structure comprising a wavelet network and a linear term. The introduction of the linear term is aimed at providing a more parsimonious interpolation in high-dimensional spaces when the modelling samples are sparse. A constructive procedure for building such structures, termed linear-wavelet networks, is described. For illustration, the proposed procedure is employed in the framework of dynamic system identification. In an example involving a simulated fermentation process, it is shown that a linear-wavelet network yields a smaller approximation error when compared with a wavelet network with the same number of regressors. The proposed technique is also applied to the identification of a pressure plant from experimental data. In this case, the results show that the introduction of wavelets considerably improves the prediction ability of a linear model. Standard errors on the estimated model coefficients are also calculated to assess the numerical conditioning of the identification process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Numerical methods are described for determining robust, or well-conditioned, solutions to the problem of pole assignment by state feedback. The solutions obtained are such that the sensitivity of the assigned poles to perturbations in the system and gain matrices is minimized. It is shown that for these solutions, upper bounds on the norm of the feedback matrix and on the transient response are also minimized and a lower bound on the stability margin is maximized. A measure is derived which indicates the optimal conditioning that may be expected for a particular system with a given set of closed-loop poles, and hence the suitability of the given poles for assignment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For linear multivariable time-invariant continuous or discrete-time singular systems it is customary to use a proportional feedback control in order to achieve a desired closed loop behaviour. Derivative feedback is rarely considered. This paper examines how derivative feedback in descriptor systems can be used to alter the structure of the system pencil under various controllability conditions. It is shown that derivative and proportional feedback controls can be constructed such that the closed loop system has a given form and is also regular and has index at most 1. This property ensures the solvability of the resulting system of dynamic-algebraic equations. The construction procedures used to establish the theory are based only on orthogonal matrix decompositions and can therefore be implemented in a numerically stable way. The problem of pole placement with derivative feedback alone and in combination with proportional state feedback is also investigated. A computational algorithm for improving the “conditioning” of the regularized closed loop system is derived.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A robust pole assignment by linear state feedback is achieved in state-space representation by selecting a feedback which minimises the conditioning of the assigned eigenvalues of the closed-loop system. It is shown here that when this conditioning is minimised, a lower bound on the stability margin in the frequency domain is maximised.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Some points of the paper by N.K. Nichols (see ibid., vol.AC-31, p.643-5, 1986), concerning the robust pole assignment of linear multiinput systems, are clarified. It is stressed that the minimization of the condition number of the closed-loop eigenvector matrix does not necessarily lead to robustness of the pole assignment. It is shown why the computational method, which Nichols claims is robust, is in fact numerically unstable with respect to the determination of the gain matrix. In replying, Nichols presents arguments to support the choice of the conditioning of the closed-loop poles as a measure of robustness and to show that the methods of J Kautsky, N. K. Nichols and P. VanDooren (1985) are stable in the sense that they produce accurate solutions to well-conditioned problems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A low cost, disposable instrument for measuring solar radiation during meteorological balloon flights through cloud layers is described. Using a photodiode detector and low thermal drift signal conditioning circuitry, the device showed less than 1% drift for temperatures varied from +20 °C to −35 °C. The angular response to radiation, which declined less rapidly than the cosine of the angle between the incident radiation and normal incidence, is used for cloud detection exploiting the motion of the platform. Oriented upwards, the natural motion imposed by the balloon allows cloud and clear air to be distinguished by the absence of radiation variability within cloud, where the diffuse radiation present is isotropic. The optical method employed by the solar radiation instrument has also been demonstrated to provide higher resolution measurements of cloud boundaries than relative humidity measurements alone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The problem of calculating the probability of error in a DS/SSMA system has been extensively studied for more than two decades. When random sequences are employed some conditioning must be done before the application of the central limit theorem is attempted, leading to a Gaussian distribution. The authors seek to characterise the multiple access interference as a random-walk with a random number of steps, for random and deterministic sequences. Using results from random-walk theory, they model the interference as a K-distributed random variable and use it to calculate the probability of error in the form of a series, for a DS/SSMA system with a coherent correlation receiver and BPSK modulation under Gaussian noise. The asymptotic properties of the proposed distribution agree with other analyses. This is, to the best of the authors' knowledge, the first attempt to propose a non-Gaussian distribution for the interference. The modelling can be extended to consider multipath fading and general modulation