Wind catcher systems have been employed in buildings in the Middle East for many centuries and they are known by different names in different parts of the region. Recently there has been an increase in the application of this approach for natural ventilation and passive cooling in the UK and other countries. This paper presents the results of experimental wind tunnel and smoke visualisation testing, combined with CFD modelling, to investigate the performance of the wind catcher. For this purpose, a full-scale commercial system was connected to a test room and positioned centrally in an open boundary wind tunnel. Because much ventilation design involves the use of computational fluid dynamics, the measured performance of the system was also compared against the results of CFD analysis. Configurations included both a heated and unheated space to determine the impact of internal heat sources on airflow rate. Good comparisons between measurement and CFD analysis were obtained. Measurements showed that sufficient air change could be achieved to meet both air quality needs and passive cooling.
Resumo:
A combined windcatcher and light pipe (SunCatcher) was installed in the seminar room at the University of Reading, UK. Monitoring of indoor environment in real weather conditions was conducted to evaluate the application of windcatchers for natural ventilation. In addition, a subjective occupancy survey was undertaken. External weather conditions and internal indoor air quality indicators were recorded. The “tracer-gas decay” method using SF6 was used to establish air change rate for various conditions. The results indicated that the ventilation rate achieved through the windcatcher depends on the difference between internal and external air temperatures, and on wind speed and direction, in agreement with other published work in the area. The indoor air quality parameters were found to be within acceptable levels when the windcatcher was in operation. The measured air change rate was between 1.5ac/h and 6.8ac/h. Occupants’ questionnaires showed 75 per cent satisfaction with the internal conditions and welcomed the installation of the systems in UK buildings.
Resumo:
This paper presents the results of performance monitoring under real winter weather conditions, controlled laboratory testing and computational fluid dynamics (CFD) analysis of a wall mounted ventilation air inlet heat convector. For real winter weather monitoring, the wall-mounted convector was installed in a laboratory room of the Engineering Building of the School of Construction Management and Engineering. Air and hot water temperatures and air speeds were measured at the entrance to the convector and in the room. The hot water temperature was controlled at 40, 60 and 80 °C. The monitoring results were later used as boundary conditions for a CFD simulation to investigate the air movement in the room. Controlled laboratory testing was conducted in laboratories at the University of Reading, UK and at Wetterstad Consultancy, Sweden. The results of the performance investigation showed that the system contributed greatly to the room heating, particularly at a water temperature of 80 °C. Also adequate fresh air was supplied to the room. Such a system is able to provide an energy efficient method of eliminating problems associated with cold winter draughts.
Resumo:
This paper deals with the energy consumption and the evaluation of the performance of air supply systems for a ventilated room involving high- and low-level supplies. The energy performance assessment is based on the airflow rate, which is related to the fan power consumption by achieving the same environmental quality performance for each case. Four different ventilation systems are considered: wall displacement ventilation, confluent jets ventilation, impinging jet ventilation and a high level mixing ventilation system. The ventilation performance of these systems will be examined by means of achieving the same Air Distribution Index (ADI) for different cases. The widely used high-level supplies require much more fan power than those for low-level supplies for achieving the same value of ADI. In addition, the supply velocity, hence the supply dynamic pressure, for a high-level supply is much larger than for low-level supplies. This further increases the power consumption for high-level supply systems. The paper considers these factors and attempts to provide some guidelines on the difference in the energy consumption associated with high and low level air supply systems. This will be useful information for designers and to the authors' knowledge there is a lack of information available in the literature on this area of room air distribution. The energy performance of the above-mentioned ventilation systems has been evaluated on the basis of the fan power consumed which is related to the airflow rate required to provide equivalent indoor environment. The Air Distribution Index (ADI) is used to evaluate the indoor environment produced in the room by the ventilation strategy being used. The results reveal that mixing ventilation requires the highest fan power and the confluent jets ventilation needs the lowest fan power in order to achieve nearly the same value of ADI.
Resumo:
In designing modern office buildings, building spaces are frequently zoned by introducing internal partitioning, which may have a significant influence on the room air environment. This internal partitioning was studied by means of model test, numerical simulation, and statistical analysis as the final stage. In this paper, the results produced from the statistical analysis are summarized and presented.
Effect of internal partitioning on indoor air quality of rooms with mixing ventilation - basic study
Resumo:
The internal partitioning, which is frequently introduced in open-space planning due to its flexibility, was tested to study its effects on the room air quality as well as ventilation performance. For the study, physical tests using a small model room and numerical modeling using CFD computation were utilized to evaluate different test conditions employing mixing ventilation from the ceiling. The partition parameters, such as its location, height, and the gap underneath, as well as contaminant source location were tested under isothermal conditions. This paper summarizes the results from the study.
Resumo:
This paper presents an investigation of the natural ventilation cooling potential (NVCP) of office buildings in the five generally recognised climate zones in China using the Thermal Resistance Ventilation (TRV) model, which is a simplified, coupled, thermal and airflow model. The acceptable operative temperature for naturally conditioned space supplied by the ASHARE Standard 55-2004 has been used for the comfort temperature setting. Dynamic simulations for a typical office room in the five representative cities, which are Harbin, Beijing, Shanghai, Kunming and Guangzhou, have been carried out. The study demonstrates that the NVCP depends on the multiple impacts of climate, the building's thermal characteristics, internal gains, ventilation profiles and regimes. The work shows how the simplified method can be used to generate detailed, indoor, operative temperature data based on the various building conditions and control profiles which are used to investigate the NVCP at the strategic design stage. The simulation results presented in this paper can be used as a reference guideline for natural ventilation design in China.
Resumo:
Background: Hawthorn (Crataegus laevigata) leaves, flowers and berries are used by herbal practitioners in the UK to treat hypertension in conjunction with prescribed drugs. Small-scale human studies support this approach. Aim: To investigate the effects of hawthorn for hypertension in patients with type 2 diabetes taking prescribed drugs. Design of study: Randomised controlled trial. Setting: General practices in Reading, UK. Method: Patients with type 2 diabetes (n = 79) were randomised to daily 1200 mg hawthorn extract (n = 39) or placebo (n = 40) for 16 weeks. At baseline and outcome a wellbeing questionnaire was completed and blood pressure and fasting blood samples taken. A food frequency questionnaire estimated nutrient intake. Results: Hypotensive drugs were used by 71% of the study population with a mean intake of 4.4 hypoglycaemic and/or hypotensive drugs. Fat intake was lower and sugar intake higher than recommendations, and low micronutrient intake was prevalent. There was a significant group difference in mean diastolic blood pressure reductions (P = 0.035): the hawthorn group showed greater reductions (baseline: 85.6 mmHg, 95% confidence interval [Cl] = 83.3 to 87.8; outcome: 83.0 mmHg, 95% Cl = 80.5 to 85.7) than the placebo group (baseline: 84.5 mmHg, 95% Cl = 82 to 87; outcome: 85.0 mmHg, 95% Cl = 82.2 to 87.8). There was no group difference in systolic blood pressure reduction from baseline (3.6 and 0.8 mmHg for hawthorn and placebo groups, respectively; P = 0.329). Although mean fat intake met current recommendations, mean sugar intake was higher and there were indications of potential multiple micronutrient deficiencies. No herb-drug interaction was found and minor health complaints were reduced from baseline in both groups. Conclusions: This is the first randomised controlled trial to demonstrate a hypotensive effect of hawthorn in patients with diabetes taking medication.
Resumo:
Background N-3 polyunsaturated fatty acids (PUFAs) from oily fish protect against death from cardiovascular disease. We aimed to assess the hypothesis that incorporation of n-3 and n-6 PUFAs into advanced atherosclerotic plaques increases and decreases plaque stability, respectively. Methods We did a randomised controlled trial of patients awaiting carotid endarterectomy. We randomly allocated patients control, sunflower oil (n-6), or fish-oil (n-3) capsules until surgery. Primary outcome was plaque morphology indicative of stability or instability, and outcome measures were concentrations of EPA, DHA, and linoleic acid in carotid plaques; plaque morphology; and presence of macrophages in plaques. Analysis was per protocol. Findings 188 patients were enrolled and randomised; 18 withdrew and eight were excluded. Duration of oil treatment was 7-189 days (median 42) and did not differ between groups. The proportions of EPA and DHA were higher in carotid plaque fractions in patients receiving fish oil compared with those receiving control (absolute difference 0.5 [95% CI 0.3-0.7], 0.4 [0.1-0.6], and 0.2 [0.1-0.4] g/100 g total fatty acids for EPA; and 0.3 [0.0-0.8], 0.4 [0.1-0.7], and 0.3 [0.1-0.6] g/100 g total fatty acids for DHA; in plaque phospholipids, cholesteryl esters, and triacylglycerols, respectively). Sunflower oil had little effect on the fatty acid composition of lipid fractions. Fewer plaques from patients being treated with fish oil had thin fibrous caps and signs of inflammation and more plaques had thick fibrous caps and no signs of inflammation, compared with plaques in patients in the control and sunflower oil groups (odds ratio 0.52 [95% CI 0.24-0.89] and 1.19 [1.02-1.57] vs control; 0.49 [0.23-0.90] and 1.16 [1.01-1.53] vs sunflower oil). The number of macrophages in plaques from patients receiving fish oil was lower than in the other two groups. Carotid plaque morphology and infiltration by macrophages did not differ between control and sunflower oil groups. Interpretation Atherosclerotic plaques readily incorporate n-3 PUFAs from fish-oil supplementation, inducing changes that can enhance stability of atherosclerotic plaques. By contrast, increased consumption of n-6 PUFAs does not affect carotid plaque fatty-acid composition or stability over the time course studied here. Stability of plaques could explain reductions in non-fatal and fatal cardiovascular events associated with increased n-3 PUFA intake.