69 resultados para Project 2002-043-B : Smart Building For Healthy and Sustainable Workplaces – Scoping Study


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acid mine drainage (AMD) is a widespread environmental problem associated with both working and abandoned mining operations. As part of an overall strategy to determine a long-term treatment option for AMD, a pilot passive treatment plant was constructed in 1994 at Wheat Jane Mine in Cornwall, UK. The plant consists of three separate systems; each containing aerobic reed beds, anaerobic cell and rock filters, and represents the largest European experimental facility of its kind. The systems only differ by the type of pre-treatment utilised to increase the pH of the influent minewater (pH<4): lime-dosed (LD), anoxic limestone drain (ALD) and lime free (LF), which receives no form of pre-treatment. The Wheal Jane pilot plant offered a unique facility and a major research project was established to evaluate the pilot plant and study in detail the biological mechanisms and the geochemical and physical processes that control passive treatment systems. The project has led to data, knowledge, models and design criteria for the future design, planning and sustainable management of passive treatment systems. A multidisciplinary team of scientists and managers from the U.K. universities, the Environment Agency and the Mining Industry has been put together to obtain the maximum advantage from the excellent facilities facility at Wheal Jane. (C) 2004 Elseaier B.V All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The principles of organization theory are applied to the organization of construction projects. This is done by proposing a framework for modelling the whole process of building procurement. This consists of a framework for describing the environments within which construction projects take place. This is followed by the development of a series of hypotheses about the organizational structure of construction projects. Four case studies are undertaken, and the extent to which their organizational structure matches the model is compared to the level of success achieved by each project. To this end there is a systematic method for evaluating the success of building project organizations, because any conclusions about the adequacy of a particular organization must be related to the degree of success achieved by that organization. In order to test these hypotheses, a mapping technique is developed. The technique offered is a development of a technique known as Linear Responsibility Analysis, and is called "3R analysis" as it deals with roles, responsibilities and relationships. The analysis of the case studies shows that they tended to suffer due to inappropriate organizational structure. One of the prevailing problems of public sector organization is that organizational structures are inadequately defined, and too cumbersome to respond to environmental demands on the project. The projects tended to be organized as rigid hierarchies, particularly at decision points, when what was required was a more flexible, dynamic and responsive organization. The study concludes with a series of recommendations; including suggestions for increasing the responsiveness of construction project organizations, and reducing the lead-in times for the inception periods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A combined windcatcher and light pipe (SunCatcher) was installed in the seminar room at the University of Reading, UK. Monitoring of indoor environment in real weather conditions was conducted to evaluate the application of windcatchers for natural ventilation. In addition, a subjective occupancy survey was undertaken. External weather conditions and internal indoor air quality indicators were recorded. The tracer-gas decay method using SF6 was used to establish air change rate for various conditions. The results indicated that the ventilation rate achieved through the windcatcher depends on the difference between internal and external air temperatures, and on wind speed and direction, in agreement with other published work in the area. The indoor air quality parameters were found to be within acceptable levels when the windcatcher was in operation. The measured air change rate was between 1.5ac/h and 6.8ac/h. Occupants questionnaires showed 75 per cent satisfaction with the internal conditions and welcomed the installation of the systems in UK buildings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Building services are worth about 2% GDP and are essential for the effective and efficient operations of the building. It is increasingly recognised that the value of a building is related to the way it supports the client organisations ongoing business operations. Building services are central to the functional performance of buildings and provide the necessary conditions for health, well-being, safety and security of the occupants. They frequently comprise several technologically distinct sub-systems and their design and construction requires the involvement of numerous disciplines and trades. Designers and contractors working on the same project are frequently employed by different companies. Materials and equipment is supplied by a diverse range of manufacturers. Facilities managers are responsible for operation of the building service in use. The coordination between these participants is crucially important to achieve optimum performance, but too often is neglected. This leaves room for serious faults. The need for effective integration is important. Modern technology offers increasing opportunities for integrated personal-control systems for lighting, ventilation and security as well as interoperability between systems. Opportunities for a new mode of systems integration are provided by the emergence of PFI/PPP procurements frameworks. This paper attempts to establish how systems integration can be achieved in the process of designing, constructing and operating building services. The essence of the paper therefore is to envisage the emergent organisational responses to the realisation of building services as an interactive systems network.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article considers how visual practices are used to manage knowledge in project-based work. It compares project-based work in a capital goods manufacturer and an architectural firm. Visual representations are used extensively in both cases, but the nature of visual practice differs significantly between the two. The research explores the kinds of knowledge that are (and aren't) developed and made visible in strategizing and planning activities. For example, whereas the emphasis of project-based work in the former firm is on exploitation of knowledge and it visualizes its project context largely in commercial and processual terms, the emphasis in the latter is on exploration and it uses a wide range of visual materials to understand physical interdependencies across the project boundary. We contend particular kinds of visual tools can help project teams step between exploration and exploitation within a project, and articulate the types of representations, foci of attention and patterns of interaction involved. The findings suggest that business managers can make more deliberate choices about how knowledge is made visible, and can change visual practice to align the project with exploring and exploiting opportunities. It raises the question: What don't you see within your organization? The work contributes to academic debates about managing through projects, strategising and organizing, while the focus on visual representation disrupts the tacit-codified dichotomy in the broad debate on knowledge and learning, and highlights the craft skills central to strategizing and organizing.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The content of this paper is a snapshot of a current project looking at producing a real-time sensor-based building assessment tool, and a system that personalises workspaces using multi-agent technology. Both systems derive physical environment information from a wireless sensor network that allows clients to subscribe to real-time sensed data. The principal ideologies behind this project are energy efficiency and well-being of occupants; in the context of leveraging the current state-of-the-art in agent technology, wireless sensor networks and building assessment systems to enable the optimisation and assessment of buildings. Participants of this project are from both industry (construction and research) and academia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the effects of substituting dietary saturated fatty acids (SFAs) with monounsaturated fatty acids (MUFAs) on postprandial chylomicron (triacylglycerol (TAG), apolipoprotein B-48 (apo B-48) and retinyl ester (RE)), chylomicron particle size and factor VII (FVII) response when subjects were given a standard meal. In a controlled sequential design, 51 healthy young subjects followed an SFA-rich diet (Reference diet) for 8 weeks after which half of the subjects followed a moderate MUFA diet (n = 25) and half followed a high MUFA diet (n = 26) for 16 weeks. Fasting lipoprotein and lipid measurements were evaluated at baseline and at 8-week intervals during the Reference and MUFA diets. In 25 of the subjects (n = 12 moderate MUFA, n = 13 high MUFA), postprandial responses to a standard test meal containing RE and 13 C-tripalmitin were investigated at the end of the Reference and the MUFA diet periods. Although there were no differences in the postprandial lipid markers (TAG, RE, C-13-TAG) on the two diets, the postprandial apo B-48 response (incremental area under the curve (IAUC) was reduced by 21% on the moderate MUFA diet (NS) and by 54% on the high MUFA diet (P < 0.01). The postprandial peak concentrations of apo B-48 were reduced by 33% on the moderate MUFA diet (P < 0.01) and 48% on the high MUFA diet (P < 0.001). Fasting values for factor VII activity (FVIIc), activated factor VII (FVIIa) or factor VII antigen (FVIIag) did not differ significantly when subjects were transferred from Reference to MUFA diets. However, the postprandial increases in coagulation FVII activity (FVIIc) were 18% lower and of activated FVII (FVIIa) were 17% lower on the moderate MUFA diet (NS). Postprandial increases in FVIIc and FVIIa were 50% (P < 0.05) and 29% (P < 0.07) lower on the high MUFA diet and the area under the postprandial FVIIc response curve (AUC) was also lower on the high MUFA diet (P < 0.05). Significantly higher ratios of RE:apo B-48 (P < 0.001) and 13 C-palmitic acid:apo B-48 (P < 0.01) during both MUFA diets suggest that the CMs formed carry larger amounts of dietary lipids per particle, reflecting an adaptation to form larger lipid droplets in the enterocyte when increased amounts of dietary MUFAs are fed. Smaller numbers of larger chylomicrons may explain attenuated activation of factor VII during the postprandial state when the background diet is rich in MUFA. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Certain milk factors may promote the growth of a host-friendly gastrointestinal microbiota, for example, one that is predominated by bifidobacteria, a perceived healthpromoting genus. This may explain why breast-fed infants experience fewer intestinal infections than their formula-fed counterparts who are believed to have a more diverse microbiota, which is similar to that of adults. The effects of formulas supplemented with 2 such ingredients from bovine milk, a-lactalbumin (alpha-lac) and casein glycomacropeptide (GMP), on gut flora were investigated in this study. Patients and Methods: Six-week-old (4-8 wk), healthy term infants were randomised to a standard infant formula or 1 of 2 test formulae enriched in alpha-Jac with higher or lower GMP until 6 months. Faecal bacteriology was determined by the culture-independent procedure fluorescence in situ hybridisation. Results: There was a large fluctuation of bacterial counts within groups with no statistically significant differences between groups. Although all groups showed a. predominance of bifidobacteria, breast-fed infants had a small temporary increase in counts. Other bacterial levels varied in formula-fed groups, which overall showed an adult-like faecal microflora. Conclusions: It can be speculated that a prebiotic effect for alpha-lac and GMP is achieved only with low starting populations of beneficial microbiota (eg, infants not initially breast-fed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The content of this paper is a snapshot of a current project looking at producing a real-time sensor-based building assessment tool, and a system that personalises work-spaces using multi-agent technology. Both systems derive physical environment information from a wireless sensor network that allows clients to subscribe to real-time sensed data. The principal ideologies behind this project are energy efficiency and well-being of occupants; in the context of leveraging the current state-of-the-art in agent technology, wireless sensor networks and building assessment systems to enable the optimisation and assessment of buildings. Participants of this project are from both industry (construction and research) and academia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

People's interaction with the indoor environment plays a significant role in energy consumption in buildings. Mismatching and delaying occupants' feedback on the indoor environment to the building energy management system is the major barrier to the efficient energy management of buildings. There is an increasing trend towards the application of digital technology to support control systems in order to achieve energy efficiency in buildings. This article introduces a holistic, integrated, building energy management model called `smart sensor, optimum decision and intelligent control' (SMODIC). The model takes into account occupants' responses to the indoor environments in the control system. The model of optimal decision-making based on multiple criteria of indoor environments has been integrated into the whole system. The SMODIC model combines information technology and people centric concepts to achieve energy savings in buildings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IPLV overall coefficient, presented by Air-Conditioning and Refrigeration Institute (ARI) of America, shows running/operation status of air-conditioning system host only. For overall operation coefficient, logical solution has not been developed, to reflect the whole air-conditioning system under part load. In this research undertaking, the running time proportions of air-conditioning systems under part load have been obtained through analysis on energy consumption data during practical operation in all public buildings in Chongqing. This was achieved by using analysis methods, based on the statistical energy consumption data distribution of public buildings month-by-month. Comparing with the weight number of IPLV, part load operation coefficient of air-conditioning system, based on this research, does not only show the status of system refrigerating host, but also reflects and calculate energy efficiency of the whole air-conditioning system. The coefficient results from the processing and analyzing of practical running data, shows the practical running status of area and building type (actual and objective) not clear. The method is different from model analysis which gets IPLV weight number, in the sense that this method of coefficient results in both four equal proportions and also part load operation coefficient of air-conditioning system under any load rate as necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study was designed to examine whether the type of fat ingested in an initial test meal influences the response and density distribution of dietary-derived lipoproteins in the Svedberg flotation rate (Sf)>400, Sf 60 - 400 and Sf 20 - 60 lipoprotein fractions. A single-blind randomized within-subject crossover design was used to study the effects of palm oil, safflower oil, a mixture of fish and safflower oil, and olive oil on postprandial apolipoprotein (apo) B-48, retinyl ester and triacylglycerol responses in each lipoprotein fraction following an initial test meal containing one of the oils and a second standardized test meal. For all dietary oils, late postprandial (300min) concentrations of triacylglycerol and apo B-48 were significantly higher in the Sf 60 - 400 fraction than in the Sf>400 fraction (P<0.02). Significantly greater apo B-48 incremental areas under the curve (IAUCs) were also observed in the Sf 60 - 400 fraction than in the Sf>400 fraction following palm oil, safflower oil and olive oil (P<0.04), with a similar non-significant trend for fish/safflower oil. Olive oil resulted in a significantly greater apo B-48 IAUC in the Sf>400 fraction (P<0.02) than did any of the other dietary oils, as well as a tendency for a higher IAUC in the Sf 60 - 400 fraction compared with the palm, safflower and fish/safflower oils. In conclusion, we have found that the majority of intestinally derived lipoproteins present in the circulation following meals enriched with saturated, polyunsaturated or monounsaturated fatty acids are of the density and size of small chylomicrons and chylomicron remnants. Olive oil resulted in a greater apo B-48 response compared with the other dietary oils following sequential test meals, suggesting the formation of a greater number of small (Sf 60 - 400) and large (Sf>400) apo B-48-containing lipoproteins in response to this dietary oil.