146 resultados para Building energy simulations


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The transition to a low-carbon economy urgently demands better information on the drivers of energy consumption. UK government policy has prioritized energy efficiency in the built stock as a means of carbon reduction, but the sector is historically information poor, particularly the non-domestic building stock. This paper presents the results of a pilot study that investigated whether and how property and energy consumption data might be combined for non-domestic energy analysis. These data were combined in a ‘Non-Domestic Energy Efficiency Database’ to describe the location and physical attributes of each property and its energy consumption. The aim was to support the generation of a range of energy-efficiency statistics for the industrial, commercial and institutional sectors of the non-domestic building stock, and to provide robust evidence for national energy-efficiency and carbon-reduction policy development and monitoring. The work has brought together non-domestic energy data, property data and mapping in a ‘data framework’ for the first time. The results show what is possible when these data are integrated and the associated difficulties. A data framework offers the potential to inform energy-efficiency policy formation and to support its monitoring at a level of detail not previously possible.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a numerical study of urban air-flow for a group of five buildings that is located at the University of Reading in the United Kingdom. The airflow around these buildings has been simulated by using ANSYS CFD software package. In this study, the association between certain architectural forms: a street canyon, a semi-closure, and a courtyard-like space in a low-rise building complex, and the wind environment were investigated. The analysis of CFD results has provided detailed information on the wind patterns of these urban built forms. The numerical results have been compared with the experimental measurements within the building complex. The observed characteristics of urban wind pattern with respect to the built structures are presented as a guideline. This information is needed for the design and/or performance assessments of systems such as passive and low energy design approach, a natural or hybrid ventilation, and passive cooling. Also, the knowledge of urban wind patterns allows us to develop better design options for the application of renewable energy technologies within urban environment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Reducing energy use in tenanted commercial property requires a greater understanding of ‘buildings as communities’. Tenanted commercial properties represent: (1) the divergent communities that share specific buildings; and (2) the organizational communities represented by multi-site landlord and tenant companies. In any particular tenanted space the opportunity for environmental change is mediated (hindered or enabled) through the lease. This discussion draws on theoretical and practical understandings of (1) the socio-legal relationships of landlords, tenants and their advisors; (2) the real performance of engineering building services strategies to improve energy efficiency; (3) how organizational cultures affect the ability of the sector to engage with energy-efficiency strategies; and (4) the financial and economic basis of the relationship between owners and occupiers. The transformational complexity stems from: (1) the variety of commercial building stock; (2) the number of stakeholders (solicitors, investors, developers, agents, owners, tenants and facilities managers); (3) the fragmentation within the communities of practice; and (4) leasehold structures and language. An agenda is proposed for truly interdisciplinary research that brings together both the physical and the social sciences of energy use in buildings so that technological solutions are made effective by an understanding of the way that buildings are used and communities behave.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This chapter covers the basic concepts of passive building design and its relevant strategies, including passive solar heating, shading, natural ventilation, daylighting and thermal mass. In environments with high seasonal peak temperatures and/or humidity (e.g. cities in temperate regions experiencing the Urban Heat Island effect), wholly passive measures may need to be supplemented with low and zero carbon technologies (LZCs). The chapter also includes three case studies: one residential, one demonstrational and one academic facility (that includes an innovative passive downdraught cooling (PDC) strategy) to illustrate a selection of passive measures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

There is growing pressure on the construction industry to deliver energy efficient, sustainable buildings but there is evidence to suggest that, in practice, designs regularly fail to achieve the anticipated levels of in-use energy consumption. One of the key factors behind this discrepancy is the behavior of the building occupants. This paper explores how insights from experimental psychology could potentially be used to reduce the gap between the predicted and actual energy performance of buildings. It demonstrates why traditional methods to engage with the occupants are not always successful and proposes a model for a more holistic approach to this issue. The paper concludes that achieving energy efficiency in buildings is not solely a technological issue and that the construction industry needs to adopt a more user-centred approach.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Systems of two-dimensional hard ellipses of varying aspect ratios and packing fractions are studied by Monte Carlo simulations in the generalised canonical ensemble. From this microscopic model, we extract a coarse-grained macroscopic Landau-de Gennes free energy as a function of packing fraction and orientational order parameter. We separate the free energy into the ideal orientational entropy of non-interacting two-dimensional spins and an excess free energy associated with excluded volume interactions. We further explore the isotropic-nematic phase transition using our empirical expression for the free energy and find that the nature of the phase transition is continuous for the aspect ratios we studied.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Rapid rates of urbanization have resulted into increased concerns of urban environment. Amongst them, wind and thermal comfort levels for pedestrians have attracted research interest. In this regards, urban wind environment is seen as a crucial components that can lead to improved thermal comfort levels for pedestrian population. High rise building in modern urban setting causes high levels of turbulence that renders discomfort to pedestrians. Additionally, a higher frequency of high ris e buildings at a particular region acts as a shield against the wind flow to the lower buildings beyond them resulting into higher levels of discomfort to users or residents. Studies conducted on developing wind flow models using Computational Fluid Dynami cs (CFD) simulations have revealed improvement in interval to height ratios can results into improved wind flow within the simulation grid. However, high value and demand for land in urban areas renders expansion to be an impractical solution. Nonetheless, innovative utilization of architectural concepts can be imagined to improve the pedestrian comfort levels through improved wind permeability. This paper assesses the possibility of through-building gaps being a solution to improve pedestrian comfort levels.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this study, the performance, yield and characteristics of a 16 year old photovoltaic (PV) system installation have been investigated. The technology, BP Saturn modules which were steel-blue polycrystalline silicon cells are no longer in production. A bespoke monitoring system has been designed to monitor the characteristics of 6 refurbished strings, of 18 modules connected in series. The total output of the system is configured to 6.5 kWp (series to parallel configuration). In addition to experimental results, the performance ratio (PR) of known values was simulated using PVSyst, a simulation software package. From calculations using experimental values, the PV system showed approximately 10% inferior power outputs to what would have been expected as standard test conditions. However, efficiency values in comparison to standard test conditions and the performance ratio (w75% from PVSyst simulations) over the past decade have remained practically the same. This output though very relevant to the possible performance and stability of aging cells, requires additional parametric studies to develop a more robust argument. The result presented in this paper is part of an on-going investigation into PV system aging effects.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Different treatments that could be implemented in the home environ-ment are evaluated with the objective of reaching a more rational and efficient use of energy. We consider that a detailed knowledge of energy-consuming behaviour is paramount for the development and implementation of new technologies, services and even policies that could result in more rational energy use. The proposed evaluation methodology is based on the development of economic experiments implemented in an experimental economics laboratory, where the behaviour of individuals when making decisions related to energy use in the domestic environment can be tested.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cool materials are characterized by having a high solar reflectance r – which is able to reduce heat gains during daytime - and a high thermal emissivity ε that enables them to dissipate the heat absorbed throughout the day during night. Despite the concept of cool roofs - i.e. the application of cool materials to roof surfaces - is well known in US since 1990s, many studies focused on their performance in both residential and commercial sectors under various climatic conditions for US countries, while only a few case studies are analyzed in EU countries. The present work aims at analyzing the thermal benefits due to their application to existing office buildings located in EU countries. Indeed, due to their weight in the existing buildings stock, as well as the very low rate of new buildings construction, the retrofit of office buildings is a topic of great concern worldwide. After an in-depth characterization of the existing buildings stock in the EU, the book gives an insight into roof energy balance due to different technological solutions, showing in which cases and to what extent cool roofs are preferable. A detailed description of the physical properties of cool materials and their availability on the market provides a solid background for the parametric analysis carried out by means of detailed numerical models that aims at evaluating cool roofs performance for various climates and office buildings configurations. With the help of dynamic simulations, the thermal behavior of representative office buildings of the existing EU buildings stock is assessed in terms of thermal comfort and energy needs for air conditioning. The results, which consider several variations of building features that may affect the resulting energy balance, show how cool roofs are an effective strategy for reducing overheating occurrences and thus improving thermal comfort in any climate. On the other hand, potential heating penalties due to a reduction in the incoming heat fluxes through the roof are taken into account, as well as the aging process of cool materials. Finally, an economic analysis of the best performing models shows the boundaries for their economic convenience.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A combination of satellite data, reanalysis products and climate models are combined to monitor changes in water vapour, clear-sky radiative cooling of the atmosphere and precipitation over the period 1979-2006. Climate models are able to simulate observed increases in column integrated water vapour (CWV) with surface temperature (Ts) over the ocean. Changes in the observing system lead to spurious variability in water vapour and clear-sky longwave radiation in reanalysis products. Nevertheless all products considered exhibit a robust increase in clear-sky longwave radiative cooling from the atmosphere to the surface; clear-sky longwave radiative cooling of the atmosphere is found to increase with Ts at the rate of ~4 Wm-2 K-1 over tropical ocean regions of mean descending vertical motion. Precipitation (P) is tightly coupled to atmospheric radiative cooling rates and this implies an increase in P with warming at a slower rate than the observed increases in CWV. Since convective precipitation depends on moisture convergence, the above implies enhanced precipitation over convective regions and reduced precipitation over convectively suppressed regimes. To quantify this response, observed and simulated changes in precipitation rate are analysed separately over regions of mean ascending and descending vertical motion over the tropics. The observed response is found to be substantially larger than the model simulations and climate change projections. It is currently not clear whether this is due to deficiencies in model parametrizations or errors in satellite retrievals.