75 resultados para laboratory instruments
Resumo:
The hazards associated with high voltage three phase inverters ond the rotating sha@s of large electrical machines have resulted in most of the engineering courses covering these topics to be predominantly theoretical. This paper describes a set of purpose built, low voltage and low cost teaching equipment which allows the “hands on I’ instruction of three phase inverters and rotating machines. By using low voltages, the student can experiment freely with the motors and inverter and can access all of the current and voltage waveforms, which until now could only be studied in text books or observed as part of laboratory demonstrations. Both the motor and the inverter designs are optimized for teaching purposes, cost around $25 and can be made with minimal effort.
Resumo:
The hazards associated with high-voltage three-phase inverters and high-powered large electrical machines have resulted in most of the engineering courses covering three-phase machines and drives theoretically. This paper describes a set of purpose-built, low-voltage, and low-cost teaching equipment that allows the hands-on instruction of three-phase inverters and rotating machines. The motivation for moving towards a system running at low voltages is that the students can safely experiment freely with the motors and inverter. The students can also access all of the current and voltage waveforms, which until now could only be studied in textbooks or observed as part of laboratory demonstrations. Both the motor and the inverter designs are for teaching purposes and require minimal effort and cost.
Resumo:
Determining rat preferences for, and behaviour towards, environmental enrichment objects allows us to provide evidence-based information about how the caged environment may be enriched. In recent years there have been many studies investigating the preferences of laboratory rodents for a wide variety of environmental enrichment objects and materials. While these have provided important information regarding the animals' perception of the items, very few studies have attempted to systematically investigate the precise attributes that constitute a preferred object and the behaviour that these objects afford. We have designed a research program to systematically study rats' motivation to interact with enrichment objects. Here we present the results from two experiments which examined the time rats spent with objects that only differed in size. This showed that rats spent longer with large objects rather than small ones, even though objects were presented individually. We also investigated the rats' behaviour with the objects in an open field and found that rats spent longer climbing on top of the large object. This behaviour continued when the large objects were laid on their sides instead of placed upright in the arena, suggesting that the rats were not simply climbing on the objects to investigate the top of the arena and thus an escape route, but instead were genuinely motivated to climb. This suggests that rat welfare could be enhanced by the addition to their cages of objects that permit climbing. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Whereas several clinical endpoints in monitoring the response to treatment in patients with Huntington's disease (HD) have been explored, there has been a paucity of research in the quality of life in such patients. The aim of this study was to validate the use of two generic health-related quality of life instruments (the Short Form 36 health survey questionnaire [SF-36] and the Sickness Impact Profile [SIP]) and to evaluate their psychometric properties. We found that both instruments demonstrated acceptable convergent validity and reliability for patients and carers. However, there was an advantage in using the SF-36 because of its more robust construct validity and test-retest reliability; furthermore, motor symptoms appeared to influence some strictly nonmotor dimensions of the SIP. On a pragmatic level, the SF-36 is shorter and quicker to administer and, therefore, easier for patients at various stages of the disease to complete. Thus, the SF-36 would appear to be the recommended instrument of choice for patients with HD and their carers, although further work needs to be done to investigate the sensitivity of this instrument longitudinally. (C) 2004 Movement Disorder Society.
Resumo:
Objective: Community-based care for mental disorders places considerable burden on families and carers. Measuring their experiences has become a priority, but there is no consensus on appropriate instruments. We aimed to review instruments carers consider relevant to their needs and assess evidence for their use. Method: A literature search was conducted for outcome measures used with mental health carers. Identified instruments were assessed for their relevance to the outcomes identified by carers and their psychometric properties. Results: Three hundred and ninety two published articles referring to 241 outcome measures were identified, 64 of which were eligible for review (used in three or more studies). Twenty-six instruments had good psychometric properties; they measured (i) carers' well-being, (ii) the experience of caregiving and (iii) carers' needs for professional support. Conclusion: Measures exist which have been used to assess the most salient aspects of carer outcome in mental health. All require further work to establish their psychometric properties fully.
Resumo:
Background Screening instruments for autistic-spectrum disorders have not been compared in the same sample. Aims To compare the Social Communication Questionnaire (SCQ), the Social Responsiveness Scale (SRS) and the Children's Communication Checklist (CCC). Method Screen and diagnostic assessments on 119 children between 9 and 13 years of age with special educational needs with and without autistic-spectrum disorders were weighted to estimate screen characteristics for a realistic target population. Results The SCQ performed best (area under receiver operating characteristic curve (AUC)=0.90; sensitivity. 6; specificity 0.78). The SRS had a lower AUC (0.77) with high sensitivity (0.78) and moderate specificity (0.67). The CCC had a high sensitivity but lower specificity (AUC=0.79; sensitivity 0.93; specificity 0.46). The AUC of the SRS and CCC was lower for children with IQ < 70. Behaviour problems reduced specificity for all three instruments. Conclusions The SCQ, SRS and CCC showed strong to moderate ability to identify autistic-spectrum disorder in this at-risk sample of school-age children with special educational needs.
Resumo:
Laboratory Fourier transform spectroscopy of pure water vapor and water vapor mixed with air has been conducted between 1200 and 8000 cm−1 and at temperatures between 293 and 351 K with the purpose of detecting and characterizing the water vapor continuum. The spectral features of the continuum within the major water absorption bands are presented and compared where possible to those from previous experimental studies and to the commonly used MT_CKD and CKD models. It was observed that in the main, both models adequately capture the general spectral form of the continuum; however, there were a number of exceptions. Overall, there is no evidence to indicate that MT_CKD is an improvement upon the older CKD model in these spectral regions. There was generally good agreement between our results and those of other experimental investigators. The general mathematical forms of the self-continuum temperature dependence, given by both Roberts et al. (1976) and CKD/MT_CKD, fit well to the experimental continuum in these spectral regions. However, the range of temperatures over which we made measurements is not sufficient to discriminate between these two forms or to exclude the possibility of other forms of temperature dependence being more appropriate. At the same time, the actual parameters currently used in CKD/MT_CKD to describe the temperature dependence in many spectral regions cannot reproduce the observed strong spectral variation in the temperature dependence. It has not been possible to make definitive conclusions about the magnitude of the continuum absorption in the far wings of the absorption bands investigated here.
Resumo:
Control systems theory can be a discipline difficult to learn without some laboratory help. With the help of focused laboratories this discipline turns to be very interesting to the students involved. The main problem is that laboratories aren't always available to students, and sometimes, when they are available, aren't big enough to a growing student population. Thus, with computer networks growing so fast, why don't create remote control labs that can be used by a large number of students? Why don't create remote control labs using Internetⓒ Copyright ?2001 IFAC Keywords: Remote Control, Computer Networks, Database, Educational Aids, Laboratory Education, Communication Control Applications.
Resumo:
Accurate estimates for the fall speed of natural hydrometeors are vital if their evolution in clouds is to be understood quantitatively. In this study, laboratory measurements of the terminal velocity vt for a variety of ice particle models settling in viscous fluids, along with wind-tunnel and field measurements of ice particles settling in air, have been analyzed and compared to common methods of computing vt from the literature. It is observed that while these methods work well for a number of particle types, they fail for particles with open geometries, specifically those particles for which the area ratio Ar is small (Ar is defined as the area of the particle projected normal to the flow divided by the area of a circumscribing disc). In particular, the fall speeds of stellar and dendritic crystals, needles, open bullet rosettes, and low-density aggregates are all overestimated. These particle types are important in many cloud types: aggregates in particular often dominate snow precipitation at the ground and vertically pointing Doppler radar measurements. Based on the laboratory data, a simple modification to previous computational methods is proposed, based on the area ratio. This new method collapses the available drag data onto an approximately universal curve, and the resulting errors in the computed fall speeds relative to the tank data are less than 25% in all cases. Comparison with the (much more scattered) measurements of ice particles falling in air show strong support for this new method, with the area ratio bias apparently eliminated.
Resumo:
In situ analysis has become increasingly important for contaminated land investigation and remediation. At present, portable techniques are used mainly as scanning tools to assess the spread and magnitude of the contamination, and are an adjunct to conventional laboratory analyses. A site in Cornwall, containing naturally occurring radioactive material (NORM), provided an opportunity for Reading University PhD student Anna Kutner to compare analytical data collected in situ with data generated by laboratory-based methods. The preliminary results in this paper extend the author‟s poster presentation at last September‟s GeoSpec2010 conference held in Lancaster.