52 resultados para electricity consumption per floor area


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Washing machine and dishwasher appliance use accounts for approximately 10% of electricity demand in EU households. The majority of this demand is due to the operation of electric heating elements inside appliances. This paper investigates the potential benefits that can be realised by adding a hot fill connection to washing appliances, with respect to carbon emissions, demand side management and renewable energy integration. Initial laboratory testing of new hot and cold fill appliances has resulted in modifications to optimise hot fill intake, and a novel numerical model presents a method of characterising appliance electricity use in different configurations. In order to validate model findings and test the use of new hot fill appliances in situ, a pilot study has recorded appliances’ resource consumption at one-minute resolution in fourteen households. The addition of hot fill reduced the total dishwasher and washing machine electricity consumption by 38% and 67% respectively. Depending on how hot water is supplied to appliances it is estimated that hot fill use results in an annual household carbon saving of up to 147 kgCO2. Further to direct electricity reduction, hot fill appliances can offer a method of time shifting demand away from peak periods without inconveniencing occupants’ lifestyles.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To examine the effects of the consumption of fish oils on the gene expression of lipoprotein lipase (LPL, EC 3.1.1.34) in human adipose tissue. In order to measure LPL mRNA in adipose tissue samples obtained by needle biopsy from human volunteers a competitive, reverse transcriptase PCR (RT-PCR) protocol was developed. Design: A randomised controlled, single blind cross over dietary study which compared the effects of a low level n-3 polyunsaturated fatty acids (PUFA) using normal foods enriched with eicosapentaenoic (EPA) and docosahexaenoic (DHA) (test diet), with non-enriched but otherwise identical foods (control). The diets were consumed for a period of 22 d with a wash out period of 5 months between the diets. Setting: Free-living individuals associated with the University of Surrey. Subjects: Six male subjects with a mean (±sd) age of 51.2±3.6 y were recruited. Major Outcome Measures: Pre-and postprandial blood samples were taken for the measurement of triacylglycerol (TAG), postheparin LPL activity and adipose tissue samples for the measurement of LPL mRNA levels. Results: Mean LPL expression values were 4.12´105 molecules of LPL mRNA per ng total RNA on the control diet and 4.60´105 molecules of LPL mRNA per ng total RNA on the n-3 PUFA enriched (test) diet. There was no significant difference between the levels of LPL expression following each diet, consistent with the lack of change in TAG levels in response to increased dietary n-3 PUFA intake. However, the change in LPL expression (Test-Control diet) correlated significantly with the change in fasting TAG levels (P=0.03, R=-0.87 and R2=0.75) and with the total area under the TAG-time response curve (P=0.003, R=-0.96 and R2=0.92) in individuals. Conclusions: These findings, although based on a small number of subjects, suggest that LPL expression may be a determinant of plasma TAG levels. The development of this methodology should allow further elucidation of the effects of dietary manipulation and disease processes on lipid clearance and regulation in human subjects.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Collectively small and medium sized enterprises (SMEs) are significant energy users although many are unregulated by existing policies due to their low carbon emissions. Carbon reduction is often not a priority but smart grids may create a new opportunity. A smart grid will give electricity suppliers a picture of real-time energy flows and the opportunity for consumers to receive financial incentives for engaging in demand side management. As well as creating incentives for local carbon reduction, engaging SMEs with smart grids has potential for contributing to wider grid decarbonisation. Modelling of buildings, business activities and technology solutions is needed to identify opportunities for carbon reduction. The diversity of the SME sector complicates strategy development. SMEs are active in almost every business area and occupy the full range of property types. This paper reviews previous modelling work, exposing valuable data on floor space and energy consumption associated with different business activities. Limitations are seen with the age of this data and an inability to distinguish SME energy use. By modelling SME energy use, electrical loads are identified which could be shifted on demand, in a smart network. Initial analysis of consumption, not constrained by existing policies, identifies heating and cooling in retail and commercial offices as having potential for demand response. Hot water in hotel and catering and retail sectors may also be significant because of the energy storage potential. Areas to consider for energy efficiency schemes are also indicated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper deals with the energy consumption and the evaluation of the performance of air supply systems for a ventilated room involving high- and low-level supplies. The energy performance assessment is based on the airflow rate, which is related to the fan power consumption by achieving the same environmental quality performance for each case. Four different ventilation systems are considered: wall displacement ventilation, confluent jets ventilation, impinging jet ventilation and a high level mixing ventilation system. The ventilation performance of these systems will be examined by means of achieving the same Air Distribution Index (ADI) for different cases. The widely used high-level supplies require much more fan power than those for low-level supplies for achieving the same value of ADI. In addition, the supply velocity, hence the supply dynamic pressure, for a high-level supply is much larger than for low-level supplies. This further increases the power consumption for high-level supply systems. The paper considers these factors and attempts to provide some guidelines on the difference in the energy consumption associated with high and low level air supply systems. This will be useful information for designers and to the authors' knowledge there is a lack of information available in the literature on this area of room air distribution. The energy performance of the above-mentioned ventilation systems has been evaluated on the basis of the fan power consumed which is related to the airflow rate required to provide equivalent indoor environment. The Air Distribution Index (ADI) is used to evaluate the indoor environment produced in the room by the ventilation strategy being used. The results reveal that mixing ventilation requires the highest fan power and the confluent jets ventilation needs the lowest fan power in order to achieve nearly the same value of ADI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To determine whether consumption of five portions of fruit and vegetables per day reduces the enhancement of oxidative stress induced by consumption of fish oil. Subjects: A total of 18 free-living healthy smoking volunteers, aged 18-63 y, were recruited by posters and e-mail in The University of Reading, and by leaflets in local shops. Design: A prospective study. Setting: Hugh Sinclair Unit of Human Nutrition, School of Food Biosciences, The University of Reading, Whiteknights PO Box 226, Reading RG6 6AP, UK. Intervention: All subjects consumed a daily supplement of 4 x 1 g fish oil capsules for 9 weeks. After 3 weeks, they consumed an additional five portions of fruits and vegetables per day, and then they returned to their normal diet for the last 3 weeks of the study. Fasting blood samples were taken at the ends of weeks 0, 3, 6 and 9. Results: The plasma concentrations of ascorbic acid, lutein, beta-cryptoxanthin, alpha-carotene and beta-carotene all significantly increased when fruit and vegetable intake was enhanced (P<0.05). Plasma concentrations of α-tocopherol, retinol and uric acid did not change significantly during the period of increased fruit and vegetable consumption. Plasma oxidative stability, assessed by the oxygen radical absorbance capacity (ORAC) assay, also increased from weeks 3-6 (P<0.001) but not in association with increases in measured antioxidants. Lag phase before oxidation of low-density lipoprotein (LDL) significantly decreased in the first 3 weeks of the study, reflecting the incorporation of EPA and DHA into LDL (P<0.0001). Subsequent enhanced fruit and vegetable consumption significantly reduced the susceptibility of LDL to oxidation (P<0.005). Conclusion: Fish oil reduced the oxidative stability of plasma and LDL, but the effects were partially offset by the increased consumption of fruit and vegetables.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Regular consumption of green tea polyphenols (GTP) is thought to reduce the risk of cardiovascular disease (CVD) but has also been associated with liver toxicity. The present trial aimed to assess the safety and potential CVD health beneficial effects of daily GTP consumption. We conducted a placebo-controlled parallel study to evaluate the chronic effects of GTP on liver function and CVD risk biomarkers in healthy men. Volunteers (treatment: n = 17, BMI 26.7 +/- 3.3 kg/m(2), age 41 +/- 9 y; placebo, n = 16, BMI 25.4 +/- 3.3 kg/m(2), age 40 +/- 10 y) consumed for 3 wk 6 capsules per day (2 before each principal meal) containing green tea extracts (equivalent to 714 mg/d GTP) or placebo. At the beginning and end of the intervention period, we collected blood samples from fasting subjects and measured vascular tone using Laser Doppler lontophoresis. Biomarkers of liver function and CVD risk (including blood pressure, plasma lipids, and asymmetric dimethylarginine) were unaffected by GTP consumption. After treatment, the ratio of total:HDL cholesterol was significantly reduced in participants taking GTP capsules compared with baseline. Endothelial-dependent and -independent vascular reactivity did not significantly differ between treatments. In conclusion, the present data suggests that the daily consumption of high doses of GTP by healthy men for 3 wk is safe but without effects on CVD risk biomarkers other than the total:HDL cholesterol ratio. J. Nutr. 139: 58-62, 2009.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the number of portions of fruit and vegetables consumed daily by a large representative sample of older men, and to determine how blood antioxidant (vitamins E, A and carotenoids) concentrations vary with fruit and vegetable consumption. Design: Cross-sectional study of free-living men. Subjects: Men aged 55-69 y (dietary data, n=1957; blood data, n=1874) participating in Phase III (1989-1993) of the Caerphilly and Speedwell Collaborative Heart Disease Studies. Methods: Dietary data were obtained by semi-quantitative food-frequency questionnaire and blood samples were analysed for antioxidant vitamins. Men were subdivided into groups on the basis of portions per day of fruit and vegetables. Within these sub-groups, mean and 95% ranges of intakes and of blood antioxidant levels were obtained. Log transformations were performed where appropriate. Results: Only 4.3% of the men met the recommended target of five portions, while 33.3% of the men consumed one or fewer portions of fruit and vegetables per day. Those men who consumed the poorest diets with respect to fruit and vegetable intakes were more likely to be from lower socio-economic classes, drink more alcohol and be current smokers. Fruit and vegetable intake reflected plasma concentrations of antioxidants, which showed a dose-response relationship to frequency of consumption. Conclusions: Older men in the UK consume much less fruit and vegetables than current recommendations. Major difficulties are likely to be encountered in trying to meet a dietary target that is clearly much higher than the fruit and vegetable consumption of large sections of the older population in the UK.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Canopy leaf area index (LAI), defined as the single-sided leaf area per unit ground area, is a quantitative measure of canopy foliar area. LAI is a controlling biophysical property of vegetation function, and quantifying LAI is thus vital for understanding energy, carbon and water fluxes between the land surface and the atmosphere. LAI is routinely available from Earth Observation (EO) instruments such as MODIS. However EO-derived estimates of LAI require validation before they are utilised by the ecosystem modelling community. Previous validation work on the MODIS collection 4 (c4) product suggested considerable error especially in forested biomes, and as a result significant modification of the MODIS LAI algorithm has been made for the most recent collection 5 (c5). As a result of these changes the current MODIS LAI product has not been widely validated. We present a validation of the MODIS c5 LAI product over a 121 km2 area of mixed coniferous forest in Oregon, USA, based on detailed ground measurements which we have upscaled using high resolution EO data. Our analysis suggests that c5 shows a much more realistic temporal LAI dynamic over c4 values for the site we examined. We find improved spatial consistency between the MODIS c5 LAI product and upscaled in situ measurements. However results also suggest that the c5 LAI product underestimates the upper range of upscaled in situ LAI measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Botswana has a basic need to explore its energy concept, this being its energy sources, generation and percentage of the population with access to electricity. At present, Botswana generates electricity from coal, which supplies about 29% (on average) of the country’s demand. The other 71% is imported mainly from South Africa (Eskom). Consequently, the dependence of Botswana on imports posses threats to the security of its energy supply. As a result, there is the need to understand the bases for a possible generation expansion that would substantiate existing documentation. In view of this need, this study investigates the existing energy sources as well as energy consumption and production levels in Botswana. The study would be further developed by making projections of the energy demand up until the year 2020. The key techniques that were used include; literature review, questionnaire survey and an empirical study. The results presented indicated that, current dependable operation capacity (i.e. 100MW) should be increased to 2,595 MW or more assuming 85% plant efficiency. This would then be able to meet the growing demand for energy use. In addition, the installed capacity would be able to support commercial and mining activities for the growth of the economy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For decades regulators in the energy sector have focused on facilitating the maximisation of energy supply in order to meet demand through liberalisation and removal of market barriers. The debate on climate change has emphasised a new type of risk in the balance between energy demand and supply: excessively high energy demand brings about significantly negative environmental and economic impacts. This is because if a vast number of users is consuming electricity at the same time, energy suppliers have to activate dirty old power plants with higher greenhouse gas emissions and higher system costs. The creation of a Europe-wide electricity market requires a systematic investigation into the risk of aggregate peak demand. This paper draws on the e-Living Time-Use Survey database to assess the risk of aggregate peak residential electricity demand for European energy markets. Findings highlight in which countries and for what activities the risk of aggregate peak demand is greater. The discussion highlights which approaches energy regulators have started considering to convince users about the risks of consuming too much energy during peak times. These include ‘nudging’ approaches such as the roll-out of smart meters, incentives for shifting the timing of energy consumption, differentiated time-of-use tariffs, regulatory financial incentives and consumption data sharing at the community level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fish oil supplementation during pregnancy alters breast milk composition, but there is little information about the impact of oily fish consumption. We determined whether increased salmon consumption during pregnancy alters breast milk fatty acid composition and immune factors. Women (n = 123) who rarely ate oily fish were randomly assigned to consume their habitual diet or to consume 2 portions of farmed salmon per week from 20 wk of pregnancy until delivery. The salmon provided 3.45 g long-chain (LC) (n-3) PUFA/wk. Breast milk fatty acid composition and immune factors [soluble CD14, transforming growth factor-b (TGFb)1, TGFb2, and secretory IgA] were analyzed at 1, 5, 14, and 28 d postpartum (PP). Breast milk from the salmon group had higher proportions of EPA (80%), docosapentaenoic acid (30%), and DHA (90%) on d 5 PP compared with controls (P < 0.01). The LC (n-6) PUFA:LC (n-3) PUFA ratio was lower for the salmon group on all days of PP sampling (P < 0.004), although individual (n-6) PUFA proportions, including arachidonic acid, did not differ. All breast milk immune factors decreased between d 1 and 28 PP (P < 0.001). Breast milk secretory IgA (sIgA) was lower in the salmon group (d 1–28 PP; P = 0.006). Salmon consumption during pregnancy, at the current recommended intakes, increases the LC (n-3) PUFA concentration of breast milk in early lactation, thus improving the supply of these important fatty acids to the breast-fed neonate. The consequence of the lower breast milk concentration of sIgA in the salmon group is not clear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Commercial kitchens often leave a large carbon footprint. A new dataset of energy performance metrics from a leading industrial partner is presented. Categorising these types of buildings is challenging. Electricity use has been analysed using data from automated meter readings (AMR) for the purpose of benchmarking and discussed in terms of factors such as size and food output. From the analysed results, consumption is found to be almost double previous sector estimates of 6480 million kWh per year. Recommendations are made to further improve the current benchmarks in order to attain robust, reliable and transparent figures, such as the introduction of normalised performance indicators to include kitchen size (m2) and kWh per thousand-pound turnover.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Commercial kitchens are one of the most profligate users of gas, water and electricity in the UK and can leave a large carbon footprint. It is estimated that the total energy consumption of Britain’s catering industry is in excess of 21,600 million kWh per year. In order to facilitate appropriate energy reduction within licensed restaurants, energy use must be translated into a form that can be compared between kitchens to enable operators to assess how they are improving and to allow rapid identification of facilities which require action. A review of relevant literature is presented and current benchmarking methods are discussed in order to assist in the development and categorisation of benchmarking energy reduction in commercial kitchens. Energy use within UK industry leading brands is discussed for the purpose of benchmarking in terms of factors such as size and output.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To analyse the influence of serving method on compliance and consumption of nutritional supplement drinks in older adults with cognitive impairment. Background: Oral nutritional supplement drinks have positive benefits on increasing nutritional status within undernourished elderly people leading to weight gain. However, consumption of these drinks is low and therefore limits their effectiveness. Design: This study was a non blind randomised control trial where participants either consumed nutritional supplement drinks in a glass/beaker or consumed them through a straw inserted directly into the container. Method: Participants with longstanding cognitive impairment were recruited from nursing homes (n=31) and hospitals (n=14). Participants were randomised to serving method. Nursing and care staff were instructed to give the supplement drinks three times per day on alternate days over a week by the allocated serving method. The researcher weighed the amount of supplement drink remaining after consumption. Data were collected over 12 months in 2011-2012. Results: 45 people participated in this study mean age 86.7 (SD 7.5 ) years. After randomisation there was no significant difference between the baseline characteristics of the two groups. Participants randomised to consume nutritional drinks from a glass / beaker drank significantly more than those who consumed them via a straw inserted directly into the container. However, supplements allocated to be given in a glass/beaker were more frequently omitted. Conclusion: Nutritional supplement drinks should be given to people with dementia who are able to feed themselves in a glass or a beaker if staffing resources allow (NIHR CSP ref 31101).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The growing dependence on electricity for economic growth in all countries prompts the need to manage current resources for future sustainability. In today’s world, greater emphasis is placed on energy conservation for energy security and for the development of every economy. However, for some countries understanding the basic drivers to such achievements is farfetched. The research presented in this paper investigates the electricity generation and access potential for Botswana. In addition detailed documentation and 13 years energy consumption and generation trends are investigated. Using questionnaires and empirical studies the energy demand for the entire nation was estimated. From the research it was established that current energy generation trends account for 38- 39% of the country’s population with access to electricity. Considering the percentage rate of sector energy demand, the proposed total installed capacity of 1332 MW, would not meet the country's energy demand at 100% access. The likely consequence of the lack of adequate supply would cumulate to significant increase of imports and/or load shedding to meet demand.