58 resultados para bilateral haptic robot control


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to ease control, the links between actuators and robotic limbs are generally made to be as stiff as possible. This is in contrast to natural limbs, where compliance is present. Springs have been added to the drive train between the actuator and load to imitate this natural compliance. The majority of these springs have been in series between the actuator and load. However, a more biologically inspired approach is taken, here springs have been used in parallel to oppose each other. The paper will describe the application of parallel extension springs in a robot arm in order to give it compliance. Advantages and disadvantages of this application are discussed along with various control strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the Gentle/G integrated system for reach & grasp therapy retraining following brain injury. The design, control and integration of an experimental grasp assistance unit is described for use in robot assisted stroke rehabilitation. The grasp assist unit is intended to work with the hardware and software of the Gentle/S robot although the hardware could be adapted to other rehabilitation applications. When used with the Gentle/S robot a total of 6 active and 3 passive degrees of freedom are available to provide active, active assist or passive grasp retraining in combination with reaching movements in a reach-grasp-transfer-release sequence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a region-based algorithm for deriving a concise description of a first order optical flow field. The algorithm described achieves performance improvements over existing algorithms without compromising the accuracy of the flow field values calculated. These improvements are brought about by not computing the entire flow field between two consecutive images, but by considering only the flow vectors of a selected subset of the images. The algorithm is presented in the context of a project to balance a bipedal robot using visual information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents results to indicate the potential applications of a direct connection between the human nervous system and a computer network. Actual experimental results obtained from a human subject study are given, with emphasis placed on the direct interaction between the human nervous system and possible extra-sensory input. An brief overview of the general state of neural implants is given, as well as a range of application areas considered. An overall view is also taken as to what may be possible with implant technology as a general purpose human-computer interface for the future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper a look is taken at how the use of implant technology can be used to either increase the range of the abilities of a human and/or diminish the effects of a neural illness, such as Parkinson's Disease. The key element is the need for a clear interface linking the human brain directly with a computer. The area of interest here is the use of implant technology, particularly where a connection is made between technology and the human brain and/or nervous system. Pilot tests and experimentation are invariably carried out apriori to investigate the eventual possibilities before human subjects are themselves involved. Some of the more pertinent animal studies are discussed here. The paper goes on to describe human experimentation, in particular that carried out by the author himself, which led to him receiving a neural implant which linked his nervous system bi-directionally with the internet. With this in place neural signals were transmitted to various technological devices to directly control them. In particular, feedback to the brain was obtained from the fingertips of a robot hand and ultrasonic (extra) sensory input. A view is taken as to the prospects for the future, both in the near term as a therapeutic device and in the long term as a form of enhancement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In over forty years of research robots have made very little progress still largely confined to industrial manufacture and cute toys, yet in the same period computing has followed Moores Law where the capacity double roughly every two years. So why is there no Moores Law for robots? Two areas stand out as worthy of research to speedup progress. The first is to get a greater understanding of how human and animal brains control movement, the second to build a new generation of robots that have greater haptic sense, that is a better ability to adapt to the environment as it is encountered. A remarkable property of the cognitive-motor system in humans and animals is that it is slow. Recognising an object may take 250 mS, a reaction time of 150 mS is considered fast. Yet despite this slow system we are well designed to allow contact with the world in a variety of ways. We can anticipate an encounter, use the change of force as a means of communication and ignore sensory cues when they are not relevant. A better understanding of these process has allowed us to build haptic interfaces to mimic the interaction. Emerging from this understanding are new ways to control the contact between robots, the user and the environment. Rehabilitation robotics has all the elements in the subject to not only enable and change the lives of people with disabilities, but also to facilitate revolution change in classic robotics.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes impedance control of redundant drive joints with double actuation (RDJ-DA) to produce compliant motions with the future goal of higher bandwidth. First, to reduce joint inertia, a double-input-single-output mechanism with one internal degree of freedom (DOF) is presented as part of the basic structure of the RDJ-DA. Next, the basic structure of RDJ-DA is further explained and its dynamics and statics are derived. Then, the impedance control scheme of RDJ-DA to produce compliant motions is proposed and the validity of the proposed controller is investigated using numerical examples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Haptic interfaces can provide highly realistic interaction with objects within their workspace, but the task of interacting with objects over large areas or volumes is made difficult by the limits of interface travel. This paper details the development of a custom haptic interface - for navigating a large virtual environment (a simulated supermarket), and investigation into different control methods which allow for haptic interaction over extremely large workspaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Robot-mediated therapies offer entirely new approaches to neurorehabilitation. In this paper we present the results obtained from trialling the GENTLE/S neurorehabilitation system assessed using the upper limb section of the Fugl-Meyer ( FM) outcome measure. Methods: We demonstrate the design of our clinical trial and its results analysed using a novel statistical approach based on a multivariate analytical model. This paper provides the rational for using multivariate models in robot-mediated clinical trials and draws conclusions from the clinical data gathered during the GENTLE/S study. Results: The FM outcome measures recorded during the baseline ( 8 sessions), robot-mediated therapy ( 9 sessions) and sling-suspension ( 9 sessions) was analysed using a multiple regression model. The results indicate positive but modest recovery trends favouring both interventions used in GENTLE/S clinical trial. The modest recovery shown occurred at a time late after stroke when changes are not clinically anticipated. Conclusion: This study has applied a new method for analysing clinical data obtained from rehabilitation robotics studies. While the data obtained during the clinical trial is of multivariate nature, having multipoint and progressive nature, the multiple regression model used showed great potential for drawing conclusions from this study. An important conclusion to draw from this paper is that this study has shown that the intervention and control phase both caused changes over a period of 9 sessions in comparison to the baseline. This might indicate that use of new challenging and motivational therapies can influence the outcome of therapies at a point when clinical changes are not expected. Further work is required to investigate the effects arising from early intervention, longer exposure and intensity of the therapies. Finally, more function-oriented robot-mediated therapies or sling-suspension therapies are needed to clarify the effects resulting from each intervention for stroke recovery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the effect of robot-mediated therapy on arm dysfunction post stroke. Design: A series of single-case studies using a randomized multiple baseline design with ABC or ACB order. Subjects (n = 20) had a baseline length of 8, 9 or 10 data points. They continued measurement during the B - robot-mediated therapy and C - sling suspension phases. Setting: Physiotherapy department, teaching hospital. Subjects: Twenty subjects with varying degrees of motor and sensory deficit completed the study. Subjects attended three times a week, with each phase lasting three weeks. Interventions: In the robot-mediated therapy phase they practised three functional exercises with haptic and visual feedback from the system. In the sling suspension phase they practised three single-plane exercises. Each treatment phase was three weeks long. Main measures: The range of active shoulder flexion, the Fugl-Meyer motor assessment and the Motor Assessment Scale were measured at each visit. Results: Each subject had a varied response to the measurement and intervention phases. The rate of recovery was greater during the robot-mediated therapy phase than in the baseline phase for the majority of subjects. The rate of recovery during the robot-mediated therapy phase was also greater than that during the sling suspension phase for most subjects. Conclusion: The positive treatment effect for both groups suggests that robot-mediated therapy can have a treatment effect greater than the same duration of non-functional exercises. Further studies investigating the optimal duration of treatment in the form of a randomized controlled trial are warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is common to make the links between actuators and robotic limbs as stiff as possible, in complete contrast to natural systems, where compliance is present. In the past, to create some compliance in a drive, springs have been added to the link between the actuator and load. Many of these springs have been in series with the drive, but recently a more 'biological' approach has been taken where two springs have been used in parallel to counteract each other. This paper describes the application of parallel extension springs in a robot arm in order to give it compliance. Advantages and disadvantages of this application are discussed, along with various control strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new strategy for controlling rigid-robot manipulators in the presence of parametric uncertainties or un-modelled dynamics. The strategy combines an adaptation law with a well known robust controller proposed by Spong, which is derived using Lyapunov's direct method. Although the tracking problem of manipulators has been successfully solved with different strategies, there are some conditions under which their efficiency is limited. Specifically, their performance decreases when unknown loading masses or model disturbances are introduced. The aim of this work is to show that the proposed strategy performs better than existing algorithms, as verified with real-time experimental results with a Puma-560 robot. (c) 2006 Elsevier Ltd. All rights reserved.