65 resultados para Stroke length
Resumo:
Typeface design: collaborative work commissioned by Adobe Inc. Published but unreleased. The Adobe Devanagari typefaces were commissioned from Tiro Typeworks and collaboratively designed by Tim Holloway, Fiona Ross and John Hudson, beginning in 2005. The types were officially released in 2009. The design brief was to produce a typeface for modern business communications in Hindi and other languages, to be legible both in print and on screen. Adobe Devanagari was designed to be highly readable in a range of situations including quite small sizes in spreadsheets and in continuous text setting, as well as at display sizes, where the full character of the typeface reveals itself. The construction of the letters is based on traditional penmanship but possesses less stroke contrast than many Devanagari types, in order to maintain strong, legible forms at smaller sizes. To achieve a dynamic, fluid style the design features a rounded treatment of distinguishing terminals and stroke reversals, open counters that also aid legibility at smaller sizes, and delicately flaring strokes. Together, these details reveal an original hand and provide a contemporary approach that is clean, clear and comfortable to read whether in short or long passages of text. This new approach to a traditional script is intended to counter the dominance of rigid, staccato-like effects of straight verticals and horizontals in earlier types and many existing fonts. OpenType Layout features in the fonts provide both automated and discretionary access to an extensive glyph set, enabling sophisticated typography. Many conjuncts preferred in classical literary texts and particularly in some North Indian languages are included; these literary conjuncts may be substituted by specially designed alternative linear forms and fitted half forms. The length of the ikars—ि and ी—varies automatically according to adjacent letter or conjunct width. Regional variants of characters and numerals (e.g. Marathi forms) are included as alternates. Careful attention has been given to the placements of all vowel signs and modifiers. The fonts include both proportional and tabular numerals in Indian and European styles. Extensive kerning covers several thousand possible combinations of half forms and full forms to anticipate arbitrary conjuncts in foreign loan words. _____
Resumo:
Searching for the optimum tap-length that best balances the complexity and steady-state performance of an adaptive filter has attracted attention recently. Among existing algorithms that can be found in the literature, two of which, namely the segmented filter (SF) and gradient descent (GD) algorithms, are of particular interest as they can search for the optimum tap-length quickly. In this paper, at first, we carefully compare the SF and GD algorithms and show that the two algorithms are equivalent in performance under some constraints, but each has advantages/disadvantages relative to the other. Then, we propose an improved variable tap-length algorithm using the concept of the pseudo fractional tap-length (FT). Updating the tap-length with instantaneous errors in a style similar to that used in the stochastic gradient [or least mean squares (LMS)] algorithm, the proposed FT algorithm not only retains the advantages from both the SF and the GD algorithms but also has significantly less complexity than existing algorithms. Both performance analysis and numerical simulations are given to verify the new proposed algorithm.
Resumo:
This work investigates the optimum decision delay and tap-length of the finite-length decision feedback equalizer. First we show that, if the feedback filter (FBF) length Nb is equal to or larger than the channel memory v and the decision delay Δ is smaller than the feedforward filter (FFF) length Nf, then only the first Δ+1 elements of the FFF can be nonzero. Based on this result we prove that the maximum effective FBF length is equal to the channel memory v, and if Nb ≥ v and Nf is long enough, the optimum decision delay that minimizes the MMSE is Nf-1.
Resumo:
The power of an adaptive equalizer is maximized when the structural parameters including the tap-length and decision delay can be optimally chosen. Although the method for adjusting either the tap-length or decision delay has been proposed, adjusting both simultaneously becomes much more involved as they interact with each other. In this paper, this problem is solved by putting a linear prewhitener before the equalizer, with which the equivalent channel becomes maximum-phase. This implies that the optimum decision delay can be simply ¯xed at the tap-length minus one, while the tap-length can then be chosen using a similar approach as that proposed in our previous work.
Resumo:
This paper investigates how to choose the optimum tap-length and decision delay for the decision feedback equalizer (DFE). Although the feedback filter length can be set as the channel memory, there is no closed-form expression for the feedforward filter length and decision delay. In this paper, first we analytically show that the two dimensional search for the optimum feedforward filter length and decision delay can be simplified to a one dimensional search, and then describe a new adaptive DFE where the optimum structural parameters can be self-adapted.
Resumo:
Most existing models of language production and speech motor control do not explicitly address how language requirements affect speech motor functions, as these domains are usually treated as separate and independent from one another. This investigation compared lip movements during bilabial closure between five individuals with mild aphasia and five age and gender-matched control speakers when the linguistic characteristics of the stimuli were varied by increasing the number of syllables. Upper and lower lip movement data were collected for mono-, bi- and tri-syllabic nonword sequences using an AG 100 EMMA system. Each task was performed under both normal and fast rate conditions. Single articulator kinematic parameters (peak velocity, amplitude, duration,and cyclic spatio-temporal index) were measured to characterize lip movements. Results revealed that compared to control speakers, individuals with aphasia showed significantly longer movement duration and lower movement stability for longer items (bi- and tri-syllables). Moreover, utterance length affected the lip kinematics, in that the monosyllables had smaller peak velocities, smaller amplitudes and shorter durations compared to bi- and trisyllables, and movement stability was lowest for the trisyllables. In addition, the rate-induced changes (smaller amplitude and shorter duration with increased rate) were most prominent for the short items (i.e., monosyllables). These findings provide further support for the notion that linguistic changes have an impact on the characteristics of speech movements, and that individuals with aphasia are more affected by such changes than control speakers.
Resumo:
Strokes affect thousands of people worldwide leaving sufferers with severe disabilities affecting their daily activities. In recent years, new rehabilitation techniques have emerged such as constraint-induced therapy, biofeedback therapy and robot-aided therapy. In particular, robotic techniques allow precise recording of movements and application of forces to the affected limb, making it a valuable tool for motor rehabilitation. In addition, robot-aided therapy can utilise visual cues conveyed on a computer screen to convert repetitive movement practice into an engaging task such as a game. Visual cues can also be used to control the information sent to the patient about exercise performance and to potentially address psychosomatic variables influencing therapy. This paper overviews the current state-of-the-art on upper limb robot-mediated therapy with a focal point on the technical requirements of robotic therapy devices leading to the development of upper limb rehabilitation techniques that facilitate reach-to-touch, fine motor control, whole-arm movements and promote rehabilitation beyond hospital stay. The reviewed literature suggest that while there is evidence supporting the use of this technology to reduce functional impairment, besides the technological push, the challenge ahead lies on provision of effective assessment of outcome and modalities that have a stronger impact transferring functional gains into functional independence.
Resumo:
A growing awareness of the potential for machine-mediated neurorehabilitation has led to several novel concepts for delivering these therapies. To get from laboratory demonstrators and prototypes to the point where the concepts can be used by clinicians in practice still requires significant additional effort, not least in the requirement to assess and measure the impact of any proposed solution. To be widely accepted a study is required to use validated clinical measures but these tend to be subjective, costly to administer and may be insensitive to the effect of the treatment. Although this situation will not change, there is good reason to consider both clinical and mechanical assessments of recovery. This article outlines the problems in measuring the impact of an intervention and explores the concept of providing more mechanical assessment techniques and ultimately the possibility of combining the assessment process with aspects of the intervention.