37 resultados para Screen printed electrodes
Resumo:
Beckett’s sparse and minimalist pieces have continuously addressed the nature and characteristics of the media for which they were written. What does it mean when a work written specifically for television is transposed to the stage, as film director Atom Egoyan did in his 2006 version of Beckett’s Eh Joe? This article will focus on the implications of such a transposition and discuss how Egoyan’s version reveals the haptic interface present in the original piece, between body and technology, between the flesh and “spirit made light” of the electronic broadcast.
Resumo:
Neuroprostheses interfaced with transected peripheral nerves are technological routes to control robotic limbs as well as convey sensory feedback to patients suffering from traumatic neural injuries or degenerative diseases. To maximize the wealth of data obtained in recordings, interfacing devices are required to have intrafascicular resolution and provide high signal-to-noise ratio (SNR) recordings. In this paper, we focus on a possible building block of a three-dimensional regenerative implant: a polydimethylsiloxane (PDMS) microchannel electrode capable of highly sensitive recordings in vivo. The PDMS 'micro-cuff' consists of a 3.5 mm long (100 µm × 70 µm cross section) microfluidic channel equipped with five evaporated Ti/Au/Ti electrodes of sub-100 nm thickness. Individual electrodes have average impedance of 640 ± 30 kΩ with a phase angle of −58 ± 1 degrees at 1 kHz and survive demanding mechanical handling such as twisting and bending. In proof-of-principle acute implantation experiments in rats, surgically teased afferent nerve strands from the L5 dorsal root were threaded through the microchannel. Tactile stimulation of the skin was reliably monitored with the three inner electrodes in the device, simultaneously recording signal amplitudes of up to 50 µV under saline immersion. The overall SNR was approximately 4. A small but consistent time lag between the signals arriving at the three electrodes was observed and yields a fibre conduction velocity of 30 m s−1. The fidelity of the recordings was verified by placing the same nerve strand in oil and recording activity with hook electrodes. Our results show that PDMS microchannel electrodes open a promising technological path to 3D regenerative interfaces.
Resumo:
This communication examines the suitability of a photo-patternable polydimethylsiloxane (PP-PDMS) elastomer as an insulating material for implantable microelectrodes. PP-PDMS is produced by mixing a photoinitiator (2-hydroxy-2-methylpropiophenone) with the PDMS base and curing agent. Subsequent exposure to UV radiation and development of the elastomeric “photo-resist” allows for the definition of well-defined openings within the PP-PDMS film. The dielectric constants of PP-PDMS and PDMS are similar (ε ≈ 2.6, f <;1MHz). Gold film microelectrodes patterned on glass or a PDMS substrate are encapsulated with PP-PDMS, while recording sites as small as 104 μm2 can be obtained in the PP-PDMS layer. The cytotoxicity of the PP-PDMS was preliminary tested in vitro by culturing 3T3 fibroblasts in PP-PDMS extracts. No adverse effects were observed in cultures exposed to PP-PDMS films initially leached in isopropanol solvent for 48h.
Resumo:
'Typeform dialogues', as originally planned for publication, was an interactive CD-based screen interface presenting a comparative survey of typeform history and description. The CD was to be held inside a printed book that included two essays and a User’s Manual. Although 'Typeform dialogues' (CD+book) was not completed as planned, a PDF file was published containing the User’s Manual, together with background information about the interface and the project it was part of. The User's Manual presents all interface sections and features (using screen grabs) and explains their editorial rationale, design, and function.
Resumo:
Prospective measurement of nutrition, cognition, and physical activity in later life would facilitate early detection of detrimental change and early intervention but is hard to achieve in community settings. Technology can simplify the task and facilitate daily data collection. The Novel Assessment of Nutrition and Ageing (NANA) toolkit was developed to provide a holistic picture of an individual's function including diet, cognition and activity levels. This study aimed to validate the NANA toolkit for data collection in the community. Forty participants aged 65 years and over trialled the NANA toolkit in their homes for three 7-day periods at four-week intervals. Data collected using the NANA toolkit were compared with standard measures of diet (four-day food diary), cognitive ability (processing speed) and physical activity (self-report). Bland–Altman analysis of dietary intake (energy, carbohydrates, protein fat) found a good relationship with the food diary and cognitive processing speed and physical activity (hours) were significantly correlated with their standard counterparts. The NANA toolkit enables daily reporting of data that would otherwise be collected sporadically while reducing demands on participants; older adults can complete the daily reporting at home without a researcher being present; and it enables prospective investigation of several domains at once