101 resultados para Photoacoustic spectrometer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laser photoacoustic spectra of vapour phase CHDCl2 reveal the presence of an interaction which has been ascribed to interbond coupling between C-H and C-D local modes. The absolute value of the interbond coupling parameter for the CHD group, determined from a fit of a model local mode hamiltonian to the experimental data, is shown to be given approximately by the geometric mean of the interbond coupling parameters of the CH2 and CD2 groups recently derived from similar studies of CH2Cl2 and CD2Cl2. Such behaviour is understood in terms of a simple analysis in which kinetic coupling effects dominate. It is suggested that C-H stretch/bend Fermi resonance is responsible for some weaker features in the spectra and modelling calculations are described which allow an order of magnitude estimate of the size of the coupling parameter involved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We use proper orthogonal decomposition (POD) to study a transient teleconnection event at the onset of the 2001 planet-encircling dust storm on Mars, in terms of empirical orthogonal functions (EOFs). There are several differences between this and previous studies of atmospheric events using EOFs. First, instead of using a single variable such as surface pressure or geopotential height on a given pressure surface, we use a dataset describing the evolution in time of global and fully three-dimensional atmospheric fields such as horizontal velocity and temperature. These fields are produced by assimilating Thermal Emission Spectrometer observations from NASA's Mars Global Surveyor spacecraft into a Mars general circulation model. We use total atmospheric energy (TE) as a physically meaningful quantity which weights the state variables. Second, instead of adopting the EOFs to define teleconnection patterns as planetary-scale correlations that explain a large portion of long time-scale variability, we use EOFs to understand transient processes due to localised heating perturbations that have implications for the atmospheric circulation over distant regions. The localised perturbation is given by anomalous heating due to the enhanced presence of dust around the northern edge of the Hellas Planitia basin on Mars. We show that the localised disturbance is seemingly restricted to a small number (a few tens) of EOFs. These can be classified as low-order, transitional, or high-order EOFs according to the TE amount they explain throughout the event. Despite the global character of the EOFs, they show the capability of accounting for the localised effects of the perturbation via the presence of specific centres of action. We finally discuss possible applications for the study of terrestrial phenomena with similar characteristics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Infrared spectra of the two stretching fundamentals of both HBS and DBS have been observed, using a continuous flow system through a multiple reflection long path cell at a pressure around 1 Torr and a Nicolet Fourier Transform spectrometer with a resolution of about 0•1 cm-1. The v3 BS stretching fundamental of DBS, near 1140 cm-1, is observed in strong Fermi resonance with the overtone of the bend 2v2. The bending fundamental v2 has not been observed and must be a very weak band. The analysis of the results in conjunction with earlier work gives the equilibrium structure (re(BH) = 1•1698(12) , re(BS) = 1•5978(3) ) and the harmonic and anharmonic force field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The intracavity photoacoustic dye laser spectrum of CHCl3 in the gas phase at 16 350 cm−1 is reported. The v=6–0 overtone of the CH stretch is observed, and found to exhibit a rotational band contour closely analogous to the v=1–0 fundamental. The implication of this result for intramolecular vibrational energy redistribution is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With a cesium-iodide prism the long wavelength range of an infrared spectrometer may be extended to 55µ The use of such a prism, the choice of optical system, and the problems of stray radiation are all discussed. Accurate data are assembled for calibration in this region, and sample calibration traces are shown. A simple gas absorption cell is described for use at long wavelengths.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Techniques for obtaining quantitative values of the temperatures and concentrations of remote hot gaseous effluents from their measured passive emission spectra have been examined in laboratory experiments. The high sensitivity of the spectrometer in the vicinity of the 2397 cm-1 band head region of CO2 has allowed the gas temperature to be calculated from the relative intensity of the observed rotational lines. The spatial distribution of the CO2 in a methane flame has been reconstructed tomographically using a matrix inversion technique. The spectrometer has been calibrated against a black body source at different temperatures and a self absorption correction has been applied to the data avoiding the need to measure the transmission directly. Reconstruction artifacts have been reduced by applying a smoothing routine to the inversion matrix.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A case study of atmospheric aerosol measurements exploring the impact of the vertical distribution of aerosol chemical composition upon the radiative budget in North-Western Europe is presented. Sub-micron aerosol chemical composition was measured by an Aerodyne Aerosol Mass Spectrometer (AMS) on both an airborne platform and a ground-based site at Cabauw in the Netherlands. The examined period in May 2008 was characterised by enhanced pollution loadings in North-Western Europe and was dominated by ammonium nitrate and Organic Matter (OM). Both ammonium nitrate and OM were observed to increase with altitude in the atmospheric boundary layer. This is primarily attributed to partitioning of semi-volatile gas phase species to the particle phase at reduced temperature and enhanced relative humidity. Increased ammonium nitrate concentrations in particular were found to strongly increase the ambient scattering potential of the aerosol burden, which was a consequence of the large amount of associated water as well as the enhanced mass. During particularly polluted conditions, increases in aerosol optical depth of 50–100% were estimated to occur due to the observed increase in secondary aerosol mass and associated water uptake. Furthermore, the single scattering albedo was also shown to increase with height in the boundary layer. These enhancements combined to increase the negative direct aerosol radiative forcing by close to a factor of two at the median percentile level. Such increases have major ramifications for regional climate predictions as semi-volatile components are often not included in aerosol models. The results presented here provide an ideal opportunity to test regional and global representations of both the aerosol vertical distribution and subsequent impacts in North-Western Europe. North-Western Europe can be viewed as an analogue for the possible future air quality over other polluted regions of the Northern Hemisphere, where substantial reductions in sulphur dioxide emissions have yet to occur. Anticipated reductions in sulphur dioxide in polluted regions will result in an increase in the availability of ammonia to form ammonium nitrate as opposed to ammonium sulphate. This will be most important where intensive agricultural practises occur. Our observations over North-Western Europe, a region where sulphur dioxide emissions have already been reduced, indicate that failure to include the semi-volatile behaviour of ammonium nitrate will result in significant errors in predicted aerosol direct radiative forcing. Such errors will be particularly significant on regional scales.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With its highly fluctuating ion production matrix-assisted laser desorption/ionization (MALDI) poses many practical challenges for its application in mass spectrometry. Instrument tuning and quantitative ion abundance measurements using ion signal alone depend on a stable ion beam. Liquid MALDI matrices have been shown to be a promising alternative to the commonly used solid matrices. Their application in areas where a stable ion current is essential has been discussed but only limited data have been provided to demonstrate their practical use and advantages in the formation of stable MALDI ion beams. In this article we present experimental data showing high MALDI ion beam stability over more than two orders of magnitude at high analytical sensitivity (low femtomole amount prepared) for quantitative peptide abundance measurements and instrument tuning in a MALDI Q-TOF mass spectrometer. Samples were deposited on an inexpensive conductive hydrophobic surface and shrunk to droplets <10 nL in size. By using a sample droplet <10 nL it was possible to acquire data from a single irradiated spot for roughly 10,000 shots with little variation in ion signal intensity at a laser repetition rate of 5-20 Hz.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stable isotope labeling combined with MS is a powerful method for measuring relative protein abundances, for instance, by differential metabolic labeling of some or all amino acids with 14N and 15N in cell culture or hydroponic media. These and most other types of quantitative proteomics experiments using high-throughput technologies, such as LC-MS/MS, generate large amounts of raw MS data. This data needs to be processed efficiently and automatically, from the mass spectrometer to statistically evaluated protein identifications and abundance ratios. This paper describes in detail an approach to the automated analysis of uniformly 14N/15N-labeled proteins using MASCOT peptide identification in conjunction with the trans-proteomic pipeline (TPP) and a few scripts to integrate the analysis workflow. Two large proteomic datasets from uniformly labeled Arabidopsis thaliana were used to illustrate the analysis pipeline. The pipeline can be fully automated and uses only common or freely available software.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electron impact ionization of dinitrogen pentoxide for incident electron energies up to about 25 eV has been investigated by use of a crossed beams quadrupole mass spectrometer system. The experiments reported in this paper detected the fragmentation products NO2+, NO+, O+, N+, and NO3+. No stable N2O5+ ion was observed. The NO3+ fragment, for which we determine an appearance energy 13.25 +/- 0.30 ev, has not been observed previously. This appearance energy is close to the calculated threshold.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a previous work, we carried out inelastic neutron scattering (INS) spectroscopy experiments and preliminary first principles calculations on alkali metal hydrides. The complete series of alkali metal hydrides, LiH, NaH, KH, RbH and CsH was measured in the high-resolution TOSCA INS spectrometer at ISIS. Here, we present the results of ab initio electronic structure calculations of the properties of the alkali metal hydrides using both the local density approximation (LDA) and the generalized gradient approximation (GGA), using the Perdew–Burke–Ernzerhof (PBE) parameterization. Properties calculated were lattice parameters, bulk moduli, dielectric constants, effective charges, electronic densities and inelastic neutron scattering (INS) spectra. We took advantage of the currently available computer power to use full lattice dynamics theory to calculate thermodynamic properties for these materials. For the alkali metal hydrides (LiH, NaH, KH, RbH and CsH) using lattice dynamics, we found that the INS spectra calculated using LDA agreed better with the experimental data than the spectra calculated using GGA. Both zero-point effects and thermal contributions to free energies had an important effect on INS and several thermodynamic properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The absorption cross-sections of Cl2O6 and Cl2O4 have been obtained using a fast flow reactor with a diode array spectrometer (DAS) detection system. The absorption cross-sections at the wavelengths of maximum absorption (lambda(max)) determined in this study are those of Cl2O6: (1.47 +/- 0.15) x 10(-17) cm(2) molecule(-1), at lambda(max) = 276 nm and T = 298 K; and Cl2O4: (9.0 +/- 2.0) x 10(-19) cm(2) molecule(-1), at lambda(max) = 234 nm and T = 298 K. Errors quoted are two standard deviations together with estimates of the systematic error. The shapes of the absorption spectra were obtained over the wavelength range 200-450 nm for Cl2O6 and 200-350 nm for Cl2O4, and were normalized to the absolute cross-sections obtained at lambda(max) for each oxide, and are presented at 1 nm intervals. These data are discussed in relation to previous measurements. The reaction of O with OCIO has been investigated with the objective of observing transient spectroscopic absorptions. A transient absorption was seen, and the possibility is explored of identifying the species with the elusive sym-ClO3 or ClO4, both of which have been characterized in matrices, but not in the gas-phase. The photolysis of OCIO was also re-examined, with emphasis being placed on the products of reaction. UV absorptions attributable to one of the isomers of the ClO dimer, chloryl chloride (ClClO2) were observed; some Cl2O4 was also found at long photolysis times, when much of the ClClO2 had itself been photolysed. We suggest that reports of Cl2O6 formation in previous studies could be a consequence of a mistaken identification. At low temperatures, the photolysis of OCIO leads to the formation of Cl2O3 as a result of the addition of the ClO primary product to OCIO. ClClO2 also appears to be one product of the reaction between O-3 and OCIO, especially when the reaction occurs under explosive conditions. We studied the kinetics of the non-explosive process using a stopped-flow technique, and suggest a value for the room-temperature rate coefficient of (4.6 +/- 0.9) x 10(-19) cm(3) molecule(-1) s(-1) (limit quoted is 2sigma random errors). The photochemical and thermal decomposition of Cl2O6 is described in this paper. For photolysis at k = 254 nm, the removal of Cl2O6 is not accompanied by the build up of any other strong absorber. The implications of the results are either that the photolysis of Cl2O6 produces Cl-2 directly, or that the initial photofragments are converted rapidly to Cl-2. In the thermal decomposition of Cl2O6, Cl2O4 was shown to be a product of reaction, although not necessarily the major one. The kinetics of decomposition were investigated using the stopped-flow technique. At relatively high [OCIO] present in the system, the decay kinetics obeyed a first-order law, with a limiting first-order rate coefficient of 0.002 s(-1). (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Commercial dodecylbenzene cable fluid was aged at temperatures of 105 and 135 degrees C in dry oxygen-free nitrogen. In addition, selected samples were aged at 135 degrees C under sealed conditions where air was excluded from the headspace above the oil. A variety of analytical techniques, such as ultra-violet visible and infra-red spectroscopy, acid number and water content measurements, were then used to characterize the aged oils. In addition, their electrical properties were assessed by dielectric spectroscopy. Compared with ageing in air, the ageing rate was reduced significantly and, as expected, no major oxidation peaks were detected in the infrared spectrometer. Significantly, very little absorbance at 680 nm ("red absorbers") was detected in samples aged with copper and, consequentially, no large increases in dielectric loss were recorded within the ageing times considered here. This study compliments previous investigations on cable fluid and 1-phenyldodecane aged in air and show that the same ageing indicators are valid in oils aged under conditions which more closely resemble those found in high voltage plant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stable isotope labeling combined with MS is a powerful method for measuring relative protein abundances, for instance, by differential metabolic labeling of some or all amino acids with N-14 and N-15 in cell culture or hydroponic media. These and most other types of quantitative proteomics experiments using high-throughput technologies, such as LC-MS/MS, generate large amounts of raw MS data. This data needs to be processed efficiently and automatically, from the mass spectrometer to statistically evaluated protein identifications and abundance ratios. This paper describes in detail an approach to the automated analysis of Uniformly N-14/N-15-labeled proteins using MASCOT peptide identification in conjunction with the trans-proteomic pipeline (TPP) and a few scripts to integrate the analysis workflow. Two large proteomic datasets from uniformly labeled Arabidopsis thaliana were used to illustrate the analysis pipeline. The pipeline can be fully automated and uses only common or freely available software.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Liquid chromatography-mass spectrometry (LC-MS) datasets can be compared or combined following chromatographic alignment. Here we describe a simple solution to the specific problem of aligning one LC-MS dataset and one LC-MS/MS dataset, acquired on separate instruments from an enzymatic digest of a protein mixture, using feature extraction and a genetic algorithm. First, the LC-MS dataset is searched within a few ppm of the calculated theoretical masses of peptides confidently identified by LC-MS/MS. A piecewise linear function is then fitted to these matched peptides using a genetic algorithm with a fitness function that is insensitive to incorrect matches but sufficiently flexible to adapt to the discrete shifts common when comparing LC datasets. We demonstrate the utility of this method by aligning ion trap LC-MS/MS data with accurate LC-MS data from an FTICR mass spectrometer and show how hybrid datasets can improve peptide and protein identification by combining the speed of the ion trap with the mass accuracy of the FTICR, similar to using a hybrid ion trap-FTICR instrument. We also show that the high resolving power of FTICR can improve precision and linear dynamic range in quantitative proteomics. The alignment software, msalign, is freely available as open source.