100 resultados para Membrane Proteome Profiling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a comparative study between LC/MALDI/MS/MS and LC/ESI/MS/MS. Diagnostic biomarkers in saliva have been identified for monitoring caries, periodontitis, oral cancer, salivary gland diseases, and systemic disorders e.g. hepatitis and HIV[1]. Saliva is similar to serum in that there are a small number of highly abundant proteins and many low abundance proteins. There are 35 previously identified salivary proteins [1-4]. We prepared a representative sample of cysteine containing peptides and oxidised them to improve their fragmentation under MALDI conditions. In total 20 proteins were identified with 6 been identified by both methods. Surprisingly there was little overlap in the peptides used to identify the proteins between the two methods

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A greater understanding of the molecular basis of hibernating myocardium may assist in identifying those patients who would most benefit from revascularization. Paired heart biopsies were taken from hypocontractile and normally-contracting myocardium (identified by cardiovascular magnetic resonance) from 6 patients with chronic stable angina scheduled for bypass grafting. Gene expression profiles of hypocontractile and normally-contracting samples were compared using Affymetrix microarrays. The data for patients with confirmed hibernating myocardium were analysed separately and a different, though overlapping, set (up to 380) of genes was identified which may constitute a molecular fingerprint for hibernating myocardium. The expression of B-type natriuretic peptide (BNP) was increased in hypocontractile relative to normally-contracting myocardium. The expression of BNP correlated most closely with the expression of proenkephalin and follistatin 3, which may constitute additional heart failure markers. Our data illustrate differential gene expression in hypocontractile and/hibernating myocardium relative to normally-contracting myocardium within individual human hearts. Changes in expression of these genes, including increased relative expression of natriuretic and other factors, may constitute a molecular signature for hypocontractile and/or hibernating myocardium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Our objective was to test the performance of CA125 in classifying serum samples from a cohort of malignant and benign ovarian cancers and age-matched healthy controls and to assess whether combining information from matrix-assisted laser desorption/ionization (MALDI) time-of-flight profiling could improve diagnostic performance. Materials and Methods: Serum samples from women with ovarian neoplasms and healthy volunteers were subjected to CA125 assay and MALDI time-of-flight mass spectrometry (MS) profiling. Models were built from training data sets using discriminatory MALDI MS peaks in combination with CA125 values and tested their ability to classify blinded test samples. These were compared with models using CA125 threshold levels from 193 patients with ovarian cancer, 290 with benign neoplasm, and 2236 postmenopausal healthy controls. Results: Using a CA125 cutoff of 30 U/mL, an overall sensitivity of 94.8% (96.6% specificity) was obtained when comparing malignancies versus healthy postmenopausal controls, whereas a cutoff of 65 U/mL provided a sensitivity of 83.9% (99.6% specificity). High classification accuracies were obtained for early-stage cancers (93.5% sensitivity). Reasons for high accuracies include recruitment bias, restriction to postmenopausal women, and inclusion of only primary invasive epithelial ovarian cancer cases. The combination of MS profiling information with CA125 did not significantly improve the specificity/accuracy compared with classifications on the basis of CA125 alone. Conclusions: We report unexpectedly good performance of serum CA125 using threshold classification in discriminating healthy controls and women with benign masses from those with invasive ovarian cancer. This highlights the dependence of diagnostic tests on the characteristics of the study population and the crucial need for authors to provide sufficient relevant details to allow comparison. Our study also shows that MS profiling information adds little to diagnostic accuracy. This finding is in contrast with other reports and shows the limitations of serum MS profiling for biomarker discovery and as a diagnostic tool

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cross-contamination between cell lines is a longstanding and frequent cause of scientific misrepresentation. Estimates from national testing services indicate that up to 36% of cell lines are of a different origin or species to that claimed. To test a standard method of cell line authentication, 253 human cell lines from banks and research institutes worldwide were analyzed by short tandem repeat profiling. The short tandem repeat profile is a simple numerical code that is reproducible between laboratories, is inexpensive, and can provide an international reference standard for every cell line. If DNA profiling of cell lines is accepted and demanded internationally, scientific misrepresentation because of cross-contamination can be largely eliminated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In membrane distillation in a conventional membrane module, the enthalpies of vaporisation and condensation are supplied and removed by changes in the temperatures of the feed and permeate streams, respectively. Less than 5% of the feed can be distilled in a single pass, because the potential changes in the enthalpies of the liquid streams are much smaller than the enthalpy of vaporisation. Furthermore, the driving force for mass transfer reduces as the feed stream temperature and vapour pressure fall during distillation. These restrictions can be avoided if the enthalpy of vaporisation is uncoupled from the heat capacities of the feed and permeate streams. A specified distillation can then be effected continuously in a single module. Calculations are presented which estimate the performance of a flat plate unit in which the enthalpy of distillation is supplied and removed by the condensing and boiling of thermal fluids in separate circuits, and the imposed temperature difference is independent of position. Because the mass flux through the membrane is dependent on vapour pressure, membrane distillation is suited to applications with a high membrane temperature. The maximum mass flux in the proposed module geometry is predicted to be 30 kg/m2 per h at atmospheric pressure when the membrane temperature is 65°C. Operation at higher membrane temperatures is predicted to raise the mass flux, for example to 85 kg/m2 per h at a membrane temperature of 100°C. This would require pressurisation to 20 bar to prevent boiling at the heating plate of the feed channel. Pre-pressurisation of the membrane pores and control of the dissolved gas concentrations in the feed and the recyled permeate should be investigated as a means to achieve high temperature membrane distillation without pore penetration and wetting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review looks at the work carried out over the past 15 years on membrane distillation and reports the conditions utilized for research. The process is still used mainly at the laboratory scale, but a few pilot plants have been built across the world, mostly for desalination and the production of potable water. Studies into membrane distillation have been concerned with the effect of mass transfer, heat transfer, and stirring rate, but the most important effect that has to be considered with this process is temperature polarization. A section on temperature polarization and the effect of boundary layers is included in this review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper concerns the modeling of membrane distillation. The model developed has been used to predict permeate fluxes using different initial operating conditions. PVDF and PTFE membranes were successfully used in a flat plate module to experimentally confirm the theoretical results. The correlation between theory and experiment was close for both membranes. The PTFE membranes produced higher fluxes than PVDF. A Versapor membrane was also used for this work. This membrane is a composite, with a thin porous layer on a support layer. It was found not to be suitable for membrane distillation. A comparison of the heat flux was also carried out. Again, there was good correlation between theory and experiment

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review looks at the work carried out over the past 15 years on membrane distillation and reports the conditions utilized for research. The process is still used mainly at the laboratory scale, but a few pilot plants have been built across the world, mostly for desalination and the production of potable water. Studies into membrane distillation have been concerned with the effect of mass transfer, heat transfer, and stirring rate, but the most important effect that has to be considered with this process is temperature polarization. A section on temperature polarization and the effect of boundary layers is included in this review.