72 resultados para ARM MOVEMENTS
Resumo:
The ARM Shortwave Spectrometer (SWS) measures zenith radiance at 418 wavelengths between 350 and 2170 nm. Because of its 1-sec sampling resolution, the SWS provides a unique capability to study the transition zone between cloudy and clear sky areas. A spectral invariant behavior is found between ratios of zenith radiance spectra during the transition from cloudy to cloud-free. This behavior suggests that the spectral signature of the transition zone is a linear mixture between the two extremes (definitely cloudy and definitely clear). The weighting function of the linear mixture is a wavelength-independent characteristic of the transition zone. It is shown that the transition zone spectrum is fully determined by this function and zenith radiance spectra of clear and cloudy regions. An important result of these discoveries is that high temporal resolution radiance measurements in the clear-to-cloud transition zone can be well approximated by lower temporal resolution measurements plus linear interpolation.
Resumo:
The main objective is to generate kinematic models for the head and neck movements. The motivation comes from our study of individuals with quadriplegia and the need to design rehabilitation aiding devices such as robots and teletheses that can be controlled by head-neck movements. It is then necessary to develop mathematical models for the head and neck movements. Two identification methods have been applied to study the kinematics of head-neck movements of able-body as well as neck-injured subjects. In particular, sagittal plane movements are well modeled by a planar two-revolute-joint linkage. In fact, the motion in joint space seems to indicate that sagittal plane movements may be classified as a single DOF motion. Finally, a spatial three-revolute-joint system has been employed to model 3D head-neck movements.
Resumo:
In this chapter we described how the inclusion of a model of a human arm, combined with the measurement of its neural input and a predictor, can provide to a previously proposed teleoperator design robustness under time delay. Our trials gave clear indications of the superiority of the NPT scheme over traditional as well as the modified Yokokohji and Yoshikawa architectures. Its fundamental advantages are: the time-lead of the slave, the more efficient, and providing a more natural feeling manipulation, and the fact that incorporating an operator arm model leads to more credible stability results. Finally, its simplicity allows less likely to fail local control techniques to be employed. However, a significant advantage for the enhanced Yokokohji and Yoshikawa architecture results from the very fact that it’s a conservative modification of current designs. Under large prediction errors, it can provide robustness through directing the master and slave states to their means and, since it relies on the passivity of the mechanical part of the system, it would not confuse the operator. An experimental implementation of the techniques will provide further evidence for the performance of the proposed architectures. The employment of neural networks and fuzzy logic, which will provide an adaptive model of the human arm and robustifying control terms, is scheduled for the near future.
Resumo:
Smooth trajectories are essential for safe interaction in between human and a haptic interface. Different methods and strategies have been introduced to create such smooth trajectories. This paper studies the creation of human-like movements in haptic interfaces, based on the study of human arm motion. These motions are intended to retrain the upper limb movements of patients that lose manipulation functions following stroke. We present a model that uses higher degree polynomials to define a trajectory and control the robot arm to achieve minimum jerk movements. It also studies different methods that can be driven from polynomials to create more realistic human-like movements for therapeutic purposes.
Resumo:
Two experiments examined imitation of lateralised body movement sequences presented at six viewing angles (0º, 60º, 120º, 180º, 240º, and 300º rotation relative to the participant’s body). Experiment 1 found that, when participants were instructed simply to ‘‘do what the model does’’, at all viewing angles they produced more actions using the same side of the body as the model (anatomical matches), than actions using the opposite side (anatomical non-matches). In Experiment 2 participants were instructed to produce either anatomical matches or anatomical non-matches of observed actions. When the model was viewed from behind (0º), the anatomically matching group were more accurate than the anatomically non-matching group, but the non-matching group was superior when the model faced the participant (180º and 240º). No reliable differences were observed between groups at 60º, 120º, and 300º. In combination, the results of Experiments 1 and 2 suggest that, when they are confronting a model, people choose to imitate the hard way; they attempt to match observed actions anatomically, in spite of the fact that anatomical matching is more subject to error than anatomical non-matching.
Resumo:
Understanding human movement is key to improving input devices and interaction techniques. This paper presents a study of mouse movements of motion-impaired users, with an aim to gaining a better understanding of impaired movement. The cursor trajectories of six motion-impaired users and three able-bodied users are studied according to their submovement structure. Several aspects of the movement are studied, including the frequency and duration of pauses between submovements, verification times, the number of submovements, the peak speed of submovements and the accuracy of submovements in two-dimensions. Results include findings that some motion-impaired users pause more often and for longer than able-bodied users, require up to five times more submovements to complete the same task, and exhibit a correlation between error and peak submovement speed that does not exist for able-bodied users.
Resumo:
Soft skin artefacts made of knitted nylon reinforced silicon rubber were fabricated mimicking octopus skin. A combination of ecoflex 0030 and 0010 were used as matrix of the composite to obtain the right stiffness for the skin artefacts. Material properties were characterised using static uniaxial tension and scissors cutting tests. Two types of tactile sensors were developed to detect normal contact; one used quantum tunnelling composite materials and the second was fabricated from silicone rubber and a conductive textile. Sensitivities of the sensors were tested by applying different modes of loading and the soft sensors were incorporated into the skin prototype. Passive suckers were developed and tested against squid suckers. An integrated skin prototype with embedded deformable sensors and attached suckers developed for the arm of an octopus inspired robot is also presented.
Resumo:
Accurate observations of cloud microphysical properties are needed for evaluating and improving the representation of cloud processes in climate models and better estimate of the Earth radiative budget. However, large differences are found in current cloud products retrieved from ground-based remote sensing measurements using various retrieval algorithms. Understanding the differences is an important step to address uncertainties in the cloud retrievals. In this study, an in-depth analysis of nine existing ground-based cloud retrievals using ARM remote sensing measurements is carried out. We place emphasis on boundary layer overcast clouds and high level ice clouds, which are the focus of many current retrieval development efforts due to their radiative importance and relatively simple structure. Large systematic discrepancies in cloud microphysical properties are found in these two types of clouds among the nine cloud retrieval products, particularly for the cloud liquid and ice particle effective radius. Note that the differences among some retrieval products are even larger than the prescribed uncertainties reported by the retrieval algorithm developers. It is shown that most of these large differences have their roots in the retrieval theoretical bases, assumptions, as well as input and constraint parameters. This study suggests the need to further validate current retrieval theories and assumptions and even the development of new retrieval algorithms with more observations under different cloud regimes.
Resumo:
Objective: A phytoestrogen-rich diet has been suggested to protect against a variety of common diseases but UK intake data on phytoestrogens or their food sources is sparse. This study aims to estimate the average intake of isoflavones, lignans, enterolignans and coumestrol from 7-day food diaries (7dFD), and to provide data on total isoflavone, lignan and phytoestrogen consumption by food group. Design: Development of a food composition database for twelve phytoestrogens and analysis of soya food and phytoestrogen consumption in a population-based study. Setting: Men and women, aged 40-79 years from the general population participating in EPIC-Norfolk between 1993 and 1997, with nutrient and food data from 7dFD. Subjects: A subset of 20 437 participants. Results: The median daily phytoestrogen intake for men was 1.20mg (interquartile range (IQR) 0.93-1.54 mg; mean 1.50 mg, SD 1.50 mg) and 0.89 mg for women (IQR 0.71-1.14 mg; mean 1.20 mg, SD 1.70 mg). In soya-consumers (SC), median daily intakes were higher: 2.86 mg in men (IQR – 1.30-7.27mg; mean 5.05 mg, SD 5.03 mg) and 3.14 mg in women (IQR – 1.09-7.33mg; mean 5.40 mg, SD 6.09 mg). In both men and women, bread made the greatest contribution to phytoestrogen intake – 40.7% and 35.7% respectively. In SC men and women, vegetable dishes and soya/goat’s/sheep’s milks were the main contributors – 42.6% and 18.9% in men and 38.8% and 29.1% in women, respectively. Conclusions: The ability to estimate phytoestrogen intake in Western populations more accurately will aid investigations into their suggested effects on health.