178 resultados para blocking algorithm
Resumo:
Forecasting atmospheric blocking is one of the main problems facing medium-range weather forecasters in the extratropics. The European Centre for Medium-Range Weather Forecasts (ECMWF) Ensemble Prediction System (EPS) provides an excellent basis for medium-range forecasting as it provides a number of different possible realizations of the meteorological future. This ensemble of forecasts attempts to account for uncertainties in both the initial conditions and the model formulation. Since 18 July 2000, routine output from the EPS has included the field of potential temperature on the potential vorticity (PV) D 2 PV units (PVU) surface, the dynamical tropopause. This has enabled the objective identification of blocking using an index based on the reversal of the meridional potential-temperature gradient. A year of EPS probability forecasts of Euro-Atlantic and Pacific blocking have been produced and are assessed in this paper, concentrating on the Euro-Atlantic sector. Standard verification techniques such as Brier scores, Relative Operating Characteristic (ROC) curves and reliability diagrams are used. It is shown that Euro-Atlantic sector-blocking forecasts are skilful relative to climatology out to 10 days, and are more skilful than the deterministic control forecast at all lead times. The EPS is also more skilful than a probabilistic version of this deterministic forecast, though the difference is smaller. In addition, it is shown that the onset of a sector-blocking episode is less well predicted than its decay. As the lead time increases, the probability forecasts tend towards a model climatology with slightly less blocking than is seen in the real atmosphere. This small under-forecasting bias in the blocking forecasts is possibly related to a westerly bias in the ECMWF model. Copyright © 2003 Royal Meteorological Society
Resumo:
It is argued that the essential aspect of atmospheric blocking may be seen in the wave breaking of potential temperature (θ) on a potential vorticity (PV) surface, which may be identified with the tropopause, and the consequent reversal of the usual meridional temperature gradient of θ. A new dynamical blocking index is constructed using a meridional θ difference on a PV surface. Unlike in previous studies, the central blocking latitude about which this difference is constructed is allowed to vary with longitude. At each longitude it is determined by the latitude at which the climatological high-pass transient eddy kinetic energy is a maximum. Based on the blocking index, at each longitude local instantaneous blocking, large-scale blocking, and blocking episodes are defined. For longitudinal sectors, sector blocking and sector blocking episodes are also defined. The 5-yr annual climatologies of the three longitudinally defined blocking event frequencies and the seasonal climatologies of blocking episode frequency are shown. The climatologies all pick out the eastern North Atlantic–Europe and eastern North Pacific–western North America regions. There is evidence that Pacific blocking shifts into the western central Pacific in the summer. Sector blocking episodes of 4 days or more are shown to exhibit different persistence characteristics to shorter events, showing that blocking is not just the long timescale tail end of a distribution. The PV–θ index results for the annual average location of Pacific blocking agree with synoptic studies but disagree with modern quantitative height field–based studies. It is considered that the index used here is to be preferred anyway because of its dynamical basis. However, the longitudinal discrepancy is found to be associated with the use in the height field index studies of a central blocking latitude that is independent of longitude. In particular, the use in the North Pacific of a latitude that is suitable for the eastern North Atlantic leads to spurious categorization of blocking there. Furthermore, the PV–θ index is better able to detect Ω blocking than conventional height field indices.
Resumo:
A set of filters based on the sequence of semiconductor edges is described which offers continuity of short-wave infrared blocking. The rejection throughout the stop region is greater than 103 for each filter and the transmission better than 70% through one octave with a square cutoff. The cutoff points are located at intervals of about two-thirds of an octave. Filters at 2.6 ,µm, 5.5 µm, and 12 µm which use a low-passing multilayer in combination with a semiconductor absorption edge are described in detail. The design of multilayers for optimum performance is discussed by analogy with the synthesis of electric circuit filters.
Resumo:
The North Pacific and Bering Sea regions represent loci of cyclogenesis and storm track activity. In this paper climatological properties of extratropical storms in the North Pacific/Bering Sea are presented based upon aggregate statistics of individual storm tracks calculated by means of a feature-tracking algorithm run using NCEP–NCAR reanalysis data from 1948/49 to 2008, provided by the NOAA/Earth System Research Laboratory and the Cooperative Institute for Research in Environmental Sciences, Climate Diagnostics Center. Storm identification is based on the 850-hPa relative vorticity field (ζ) instead of the often-used mean sea level pressure; ζ is a prognostic field, a good indicator of synoptic-scale dynamics, and is directly related to the wind speed. Emphasis extends beyond winter to provide detailed consideration of all seasons. Results show that the interseasonal variability is not as large during the spring and autumn seasons. Most of the storm variables—genesis, intensity, track density—exhibited a maxima pattern that was oriented along a zonal axis. From season to season this axis underwent a north–south shift and, in some cases, a rotation to the northeast. This was determined to be a result of zonal heating variations and midtropospheric moisture patterns. Barotropic processes have an influence in shaping the downstream end of storm tracks and, together with the blocking influence of the coastal orography of northwest North America, result in high lysis concentrations, effectively making the Gulf of Alaska the “graveyard” of Pacific storms. Summer storms tended to be longest in duration. Temporal trends tended to be weak over the study area. SST did not emerge as a major cyclogenesis control in the Gulf of Alaska.
Resumo:
There is widely believed to be a link between stratospheric flow variability and stationary, persistent “blocking” weather systems, but the precise nature of this link has proved elusive. Using data from the ERA-40 Reanalysis and an atmospheric general circulation model (GCM) with a well-resolved stratosphere (HadGAM), it is shown that there are in fact several different highly significant associations, with blocking in different regions being related to different patterns of stratospheric variability. This is true in both hemispheres and in both data sets. The associations in HadGAM are shown to be very similar to those in ERA-40, although the model has a tendency to underestimate both European blocking and the wave number 2 stratospheric variability to which this is related. Although the focus is on stratospheric variability in general, several of the blocking links are seen to occur in association with the major stratospheric sudden warmings. In general, the direction of influence appears to be upward, as blocking anomalies are shown to modify the planetary stationary waves, leading to an upward propagation of wave activity into the stratosphere. However, significant correlations are also apparent with the zonal mean flow in the stratosphere leading the occurrence of blocking at high latitudes. Finally, the underestimation of blocking is an enduring problem in GCMs, and an example has recently been given in which improving the resolution of the stratosphere improved the representation of blocking. Here, however, another example is given, in which increasing the stratospheric resolution unfortunately does not lead to an improvement in blocking.
Resumo:
This paper presents a parallel genetic algorithm to the Steiner Problem in Networks. Several previous papers have proposed the adoption of GAs and others metaheuristics to solve the SPN demonstrating the validity of their approaches. This work differs from them for two main reasons: the dimension and the characteristics of the networks adopted in the experiments and the aim from which it has been originated. The reason that aimed this work was namely to build a comparison term for validating deterministic and computationally inexpensive algorithms which can be used in practical engineering applications, such as the multicast transmission in the Internet. On the other hand, the large dimensions of our sample networks require the adoption of a parallel implementation of the Steiner GA, which is able to deal with such large problem instances.
Resumo:
The paper presents a design for a hardware genetic algorithm which uses a pipeline of systolic arrays. These arrays have been designed using systolic synthesis techniques which involve expressing the algorithm as a set of uniform recurrence relations. The final design divorces the fitness function evaluation from the hardware and can process chromosomes of different lengths, giving the design a generic quality. The paper demonstrates the design methodology by progressively re-writing a simple genetic algorithm, expressed in C code, into a form from which systolic structures can be deduced. This paper extends previous work by introducing a simplification to a previous systolic design for the genetic algorithm. The simplification results in the removal of 2N 2 + 4N cells and reduces the time complexity by 3N + 1 cycles.
Resumo:
We advocate the use of systolic design techniques to create custom hardware for Custom Computing Machines. We have developed a hardware genetic algorithm based on systolic arrays to illustrate the feasibility of the approach. The architecture is independent of the lengths of chromosomes used and can be scaled in size to accommodate different population sizes. An FPGA prototype design can process 16 million genes per second.
Resumo:
Capturing the pattern of structural change is a relevant task in applied demand analysis, as consumer preferences may vary significantly over time. Filtering and smoothing techniques have recently played an increasingly relevant role. A dynamic Almost Ideal Demand System with random walk parameters is estimated in order to detect modifications in consumer habits and preferences, as well as changes in the behavioural response to prices and income. Systemwise estimation, consistent with the underlying constraints from economic theory, is achieved through the EM algorithm. The proposed model is applied to UK aggregate consumption of alcohol and tobacco, using quarterly data from 1963 to 2003. Increased alcohol consumption is explained by a preference shift, addictive behaviour and a lower price elasticity. The dynamic and time-varying specification is consistent with the theoretical requirements imposed at each sample point. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Studies in polytunnels were conducted to investigate the effects of ultraviolet (UV)-blocking films on naturally occurring insect pests and their arthropod natural enemies on a cucumber crop. Within tunnels clad with Antibotrytis (blocks light < 400 nm) and UVI/EVA (UV transmitting), 5.8 and 23.4 times more aphids, respectively, were recorded on traps compared with those on traps within tunnels clad with XL 385 (blocks light < 385 nm). When all plants within the UVI/EVA tunnels had become heavily infested with aphids, half of the plants in XL 385 tunnels were uninfested. More Coleoptera and thrips (approximately two times) were recorded under the UVI/EVA film than under the UV-blocking films, but for other arthropod pests (e. g. whitefly, leafhoppers), clear conclusions could not be drawn as low numbers were recorded. Substantial numbers of chalcid parasitoids and syrphids were found under the UV-blocking films, but further research is needed to evaluate fully the effect of such films on biological control of aphids. Higher syrphid numbers and more aphid mummies were recorded under the UVI/EVA film, probably because of the higher numbers of aphids present in tunnels clad with this film. The potential that UV-blocking films have as an effective component of commercial Integrated Pest Management (IPM) systems, for protected horticultural crops, is discussed.
Resumo:
The parasitoid Encarsia formosa Gahan (Hymenoptera: Aphelinidae) has been used successfully for the control of Trialeurodes vaporariorum (Westwood) (Homoptera: Aleyrodidae). The development of UV-blocking plastic films has added a new component to future integrated pest management systems by disrupting insect pest infestation when UV light is excluded. Because both T. vaporariorum and E. formosa are reported to have similar spectral efficiency, there was a need to identify the impact of UV-blocking films on the dispersal behavior of both the pest and the natural enemy. In field studies, using choice-chamber experiments, E. formosa showed some preference to disperse into compartments where less UV light was blocked. However, further studies indicated that the effect was primarily attributable to the different light diffusion properties of the films tested. Thus, unlike its whitefly host, when the UV-absorbing properties of the films were similar, but the light diffusion properties differed, E.formosa adults preferred to disperse into compartments clad with films that had high light diffusion properties. When the plastic films differed most in their UV-absorbing capacity and had no light-diffusion capability, the initial dispersal of E. formosa between treatments was similar, although a small preference toward the environment with UV light was observed over time. When parasitoid dispersal was measured 3 h after release, more parasitoids were found on plants, suggesting that the parasitoids would search plants for whitefly hosts, even in a UV-blocked light environment. The potential for the integration of UV-blocking films with E. formosa in an advanced whitefly management system is discussed.