90 resultados para Rotation matrix
Resumo:
Some absorption bands of diazomethane vapour between 1950-3500 cm-1 have been measured with very high resolving power. The rotational structure of two parallel bands and of one perpendicular band has been resolved, and approximate values have been determined for the rotational constants. The results are consistent with the geometrical structure usually accepted for this molecule. A peculiarity in the results for the band near 2100 cm-1, together with other facts, leads to the suggestion that a tautomeric form of this molecule exists, HCN=NH, being an isoelectronic analogue of hydrazoic acid.
Resumo:
High-resolution Fourier-transform infrared spectra have been recorded and analyzed for the nu4, nu5, and nu6 fundamental bands of trans-HONO, and for the nu4 fundamental of cis-HONO. The spectral resolution was better than 0.01/cm, and the rotational structure has been analyzed to give improved ground-state and excited-state rotational constants, with a standard deviation of the fit to the observed line positions of around 0.0006/cm. Two Coriolis interactions have been analyzed between the nu5 and nu6 bands of trans-HONO.
Resumo:
High resolution vibration-rotation spectra of 13C2H2 were recorded in a number of regions from 2000 to 5200 cm−1 at Doppler or pressure limited resolution. In these spectral ranges cold and hot bands involving the bending-stretching combination levels have been analyzed up to high J values. Anharmonic quartic resonances for the combination levels ν1 + mν4 + nν5, ν2 + mν4 + (n + 2) ν5 and ν3 + (m − 1) ν4 + (n + 1) ν5 have been studied, and the l-type resonances within each polyad have been explicitly taken into account in the analysis of the data. The least-squares refinement provides deperturbed values for band origins and rotational constants, obtained by fitting rotation lines only up to J ≈ 20 with root mean square errors of ≈ 0.0003 cm−1. The band origins allowed us to determine a number of the anharmonicity constants xij0.
Resumo:
The fundamental vibration-rotational absorption band of hydrogen chloride near 3 45,t has been remeasured using higher resolving power than previously. The wave-lengths of the absorption lines have been determined more precisely, and the isotopic splitting of lines has been completely resolved. The results have provided new and more satisfactory values for the rotational constants Bi, and the centrifugal stretching constants Di, and their relative values for the two isotopic species agree closely with what is to be expected for the difference in mass. The positions of the lines in the pure rotational absorption spectrum have been calculated from the derived data, and agree closely with those recently observed. The bond lengths re for each isotopic species H35C1 and H37C1 is found to be 1-2744A.
Resumo:
The vibrational spectrum of dimethyl acetylene has been remeasured with better resolving power than hitherto, and the rotational fine structure of some perpendicular type bands has been partly analyzed. The energy levels of a molecule of this kind in which internal rotation of methyl groups may arise have been re-examined theoretically and the rotational structure of the absorption bands has been more clearly defined than previously. The experimental results are consistent with the assumption of unrestricted internal rotation of the methyl groups, and the Coriolis factors $\zeta _{i}$ for several vibrations have been determined.
Resumo:
Rotation lines in the fundamental vibration bands of 13C16O and 12C180 have been measured, using very high resolving power and more accurate wavelength calibrations than previously. The molecular rotational and vibrational constants have been deduced and compared in relation to the mass differences between these molecules and the main species 12C160.
Resumo:
The problems of inverting experimental information obtained from vibration-rotation spectroscopy to determine the potential energy surface of a molecule are discussed, both in relation to semi-rigid molecules like HCN, NO2, H2CO, etc., and in relation to non-rigid or floppy molecules with large amplitude vibrations like HCNO, C3O2, and small ring molecules. Although standard methods exist for making the necessary calculations in the former case, they are complex, and they require an abundance of precise data on the spectrum that is rarely available. In the case of floppy molecules there are often data available over many excited states of the large amplitude vibration, but there are difficulties in knowing the precise form of the large amplitude coordinate(s), and in allowing for the vibrational averaging effects of the other modes. In both cases difficulties arise from the curvilinear nature of the vibrational paths which are not adequately handled by our present theories.
Resumo:
High-resolution Fourier transform infrared spectra have been recorded and analyzed for the ν3, ν4, ν5, and ν6 fundamental bands of trans-DONO, and for the ν4 fundamental of cis-DONO. The spectral resolution was better than 0.01 cm−1, and the bands have been fitted using an asymmetric top Hamiltonian with a standard deviation of around 0.0006 cm−1.
Resumo:
The influence matrix is used in ordinary least-squares applications for monitoring statistical multiple-regression analyses. Concepts related to the influence matrix provide diagnostics on the influence of individual data on the analysis - the analysis change that would occur by leaving one observation out, and the effective information content (degrees of freedom for signal) in any sub-set of the analysed data. In this paper, the corresponding concepts have been derived in the context of linear statistical data assimilation in numerical weather prediction. An approximate method to compute the diagonal elements of the influence matrix (the self-sensitivities) has been developed for a large-dimension variational data assimilation system (the four-dimensional variational system of the European Centre for Medium-Range Weather Forecasts). Results show that, in the boreal spring 2003 operational system, 15% of the global influence is due to the assimilated observations in any one analysis, and the complementary 85% is the influence of the prior (background) information, a short-range forecast containing information from earlier assimilated observations. About 25% of the observational information is currently provided by surface-based observing systems, and 75% by satellite systems. Low-influence data points usually occur in data-rich areas, while high-influence data points are in data-sparse areas or in dynamically active regions. Background-error correlations also play an important role: high correlation diminishes the observation influence and amplifies the importance of the surrounding real and pseudo observations (prior information in observation space). Incorrect specifications of background and observation-error covariance matrices can be identified, interpreted and better understood by the use of influence-matrix diagnostics for the variety of observation types and observed variables used in the data assimilation system. Copyright © 2004 Royal Meteorological Society
Resumo:
With its highly fluctuating ion production matrix-assisted laser desorption/ionization (MALDI) poses many practical challenges for its application in mass spectrometry. Instrument tuning and quantitative ion abundance measurements using ion signal alone depend on a stable ion beam. Liquid MALDI matrices have been shown to be a promising alternative to the commonly used solid matrices. Their application in areas where a stable ion current is essential has been discussed but only limited data have been provided to demonstrate their practical use and advantages in the formation of stable MALDI ion beams. In this article we present experimental data showing high MALDI ion beam stability over more than two orders of magnitude at high analytical sensitivity (low femtomole amount prepared) for quantitative peptide abundance measurements and instrument tuning in a MALDI Q-TOF mass spectrometer. Samples were deposited on an inexpensive conductive hydrophobic surface and shrunk to droplets <10 nL in size. By using a sample droplet <10 nL it was possible to acquire data from a single irradiated spot for roughly 10,000 shots with little variation in ion signal intensity at a laser repetition rate of 5-20 Hz.
Resumo:
It has become evident that the mystery of life will not be deciphered just by decoding its blueprint, the genetic code. In the life and biomedical sciences, research efforts are now shifting from pure gene analysis to the analysis of all biomolecules involved in the machinery of life. One area of these postgenomic research fields is proteomics. Although proteomics, which basically encompasses the analysis of proteins, is not a new concept, it is far from being a research field that can rely on routine and large-scale analyses. At the time the term proteomics was coined, a gold-rush mentality was created, promising vast and quick riches (i.e., solutions to the immensely complex questions of life and disease). Predictably, the reality has been quite different. The complexity of proteomes and the wide variations in the abundances and chemical properties of their constituents has rendered the use of systematic analytical approaches only partially successful, and biologically meaningful results have been slow to arrive. However, to learn more about how cells and, hence, life works, it is essential to understand the proteins and their complex interactions in their native environment. This is why proteomics will be an important part of the biomedical sciences for the foreseeable future. Therefore, any advances in providing the tools that make protein analysis a more routine and large-scale business, ideally using automated and rapid analytical procedures, are highly sought after. This review will provide some basics, thoughts and ideas on the exploitation of matrix-assisted laser desorption/ ionization in biological mass spectrometry - one of the most commonly used analytical tools in proteomics - for high-throughput analyses.
Resumo:
We have combined several key sample preparation steps for the use of a liquid matrix system to provide high analytical sensitivity in automated ultraviolet -- matrix-assisted laser desorption/ionisation -- mass spectrometry (UV-MALDI-MS). This new sample preparation protocol employs a matrix-mixture which is based on the glycerol matrix-mixture described by Sze et al. The low-femtomole sensitivity that is achievable with this new preparation protocol enables proteomic analysis of protein digests comparable to solid-state matrix systems. For automated data acquisition and analysis, the MALDI performance of this liquid matrix surpasses the conventional solid-state MALDI matrices. Besides the inherent general advantages of liquid samples for automated sample preparation and data acquisition the use of the presented liquid matrix significantly reduces the extent of unspecific ion signals in peptide mass fingerprints compared to typically used solid matrices, such as 2,5-dihydroxybenzoic acid (DHB) or alpha-cyano-hydroxycinnamic acid (CHCA). In particular, matrix and low-mass ion signals and ion signals resulting from cation adduct formation are dramatically reduced. Consequently, the confidence level of protein identification by peptide mass mapping of in-solution and in-gel digests is generally higher.