21 resultados para QUANTITATION


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Listeria monocytogenes the alternative sigma factor σB plays important roles in both virulence and stress tolerance. In this study a proteomic approach was used to define components of the σB regulon in L. monocytogenes 10403S (serotype 1/2a). Using two-dimensional gel electrophoresis and the recently developed isobaric tags for relative and absolute quantitation technique, the protein expression profiles of the wild type and an isogenic ΔsigB deletion strain were compared. Overall, this study identified 38 proteins whose expression was σB dependent; 17 of these proteins were found to require the presence of σB for full expression, while 21 were expressed at a higher level in the ΔsigB mutant background. The data obtained with the two proteomic approaches showed limited overlap (four proteins were identified by both methods), a finding that highlights the complementarity of the two technologies. Overall, the proteomic data reaffirmed a role for σB in the general stress response and highlighted a probable role for σB in metabolism, especially in the utilization of alternative carbon sources. Proteomic and physiological data revealed the involvement of σB in glycerol metabolism. Five newly identified members of the σB regulon were shown to be under direct regulation of σB using reverse transcription-PCR (RT-PCR), while random amplification of cDNA ends-PCR was used to map four σB-dependent promoters upstream from lmo0796, lmo1830, lmo2391, and lmo2695. Using RT-PCR analysis of known and newly identified σB-dependent genes, as well as proteomic analyses, σB was shown to play a major role in the stationary phase of growth in complex media.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The butanol-HCl spectrophotometric assay is widely used for quantifying extractable and insoluble condensed tannins (CT, syn. proanthocyanidins) in foods, feeds, and foliage of herbaceous and woody plants, but the method underestimates total CT content when applied directly to plant material. To improve CT quantitation, we tested various cosolvents with butanol-HCl and found that acetone increased anthocyanidin yields from two forage Lotus species having contrasting procyanidin and prodelphinidin compositions. A butanol-HCl-iron assay run with 50% (v/v) acetone gave linear responses with Lotus CT standards and increased estimates of total CT in Lotus herbage and leaves by up to 3.2-fold over the conventional method run without acetone. The use of thiolysis to determine the purity of CT standards further improved quantitation. Gel-state 13C and 1H–13C HSQC NMR spectra of insoluble residues collected after butanol-HCl assays revealed that acetone increased anthocyanidin yields by facilitating complete solubilization of CT from tissue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the development of a rapid method with ultraperformance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) for the qualitative and quantitative analyses of plant proanthocyanidins directly from crude plant extracts. The method utilizes a range of cone voltages to achieve the depolymerization step in the ion source of both smaller oligomers and larger polymers. The formed depolymerization products are further fragmented in the collision cell to enable their selective detection. This UPLC-MS/MS method is able to separately quantitate the terminal and extension units of the most common proanthocyanidin subclasses, that is, procyanidins and prodelphinidins. The resulting data enable (1) quantitation of the total proanthocyanidin content, (2) quantitation of total procyanidins and prodelphinidins including the procyanidin/prodelphinidin ratio, (3) estimation of the mean degree of polymerization for the oligomers and polymers, and (4) estimation of how the different procyanidin and prodelphinidin types are distributed along the chromatographic hump typically produced by large proanthocyanidins. All of this is achieved within the 10 min period of analysis, which makes the presented method a significant addition to the chemistry tools currently available for the qualitative and quantitative analyses of complex proanthocyanidin mixtures from plant extracts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a new concept for rapid and fully portable Prostate Specific Antigen (PSA) measurement, termed “Lab-in-a-Briefcase”, which integrates an affordable microfluidic ELISA platform utilising a melt-extruded fluoropolymer Micro Capillary Film (MCF) containing 10 bore, 200 μm internal diameter capillaries, a disposable multi-syringe aspirator (MSA) plus a sample tray pre-loaded with all required immunoassay reagents, and a portable film scanner for colorimetric signal digital quantitation. Each MSA can perform 10 replicate microfluidic immunoassays on 8 samples, allowing 80measurements to be made in less than 15 minutes based on semi-automated operation and norequirement of additional fluid handling equipment. An assay was optimised for measurement of a clinically relevant range of PSA from 0.9 to 60.0 ng/ml in 15 minutes with CVs in the order of 5% based on intra-assay variability when read using a consumer flatbed film scanner. The PSA assay performance in the MSA remained robust in the presence of undiluted or 1:2 diluted human serum or whole blood, and the matrix effect could simply be overcome by extending sample incubation times. The PSA "Lab-in-a-briefcase" is particularly suited to a low-resource health setting where diagnostic labs and automated immunoassay systems are not accessible, by allowing PSA measurement outside the laboratory using affordable equipment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glutamine synthetase (GS) is a key enzyme in nitrogen (N) assimilation, particularly during seed development. Three cytosolic GS isoforms (HvGS1) were identified in barley (Hordeum vulgare L. cv Golden Promise). Quantitation of gene expression, localization and response to N supply revealed that each gene plays a non-redundant role in different tissues and during development. Localization of HvGS1_1 in vascular cells of different tissues, combined with its abundance in the stem and its response to changes in N supply, indicate that it is important in N transport and remobilization. HvGS1_1 is located on chromosome 6H at 72.54 cM, close to the marker HVM074 which is associated with a major quantitative trait locus (QTL) for grain protein content (GPC). HvGS1_1 may be a potential candidate gene to manipulate barley GPC. HvGS1_2 mRNA was localized to the leaf mesophyll cells, in the cortex and pericycle of roots, and was the dominant HvGS1 isoform in these tissues. HvGS1_2 expression increased in leaves with an increasing supply of N, suggesting its role in the primary assimilation of N. HvGS1_3 was specifically and predominantly localized in the grain, being highly expressed throughout grain development. HvGS1_3 expression increased specifically in the roots of plants grown on high NH+4, suggesting that it has a primary role in grain N assimilation and also in the protection against ammonium toxicity in roots. The expression of HvGS1 genes is directly correlated with protein and enzymatic activity, indicating that transcriptional regulation is of prime importance in the control of GS activity in barley.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immunodiagnostic microneedles provide a novel way to extract protein biomarkers from the skin in a minimally invasive manner for analysis in vitro. The technology could overcome challenges in biomarker analysis specifically in solid tissue, which currently often involves invasive biopsies. This study describes the development of a multiplex immunodiagnostic device incorporating mechanisms to detect multiple antigens simultaneously, as well as internal assay controls for result validation. A novel detection method is also proposed. It enables signal detection specifically at microneedle tips and therefore may aid the construction of depth profiles of skin biomarkers. The detection method can be coupled with computerised densitometry for signal quantitation. The antigen specificity, sensitivity and functional stability of the device were assessed against a number of model biomarkers. Detection and analysis of endogenous antigens (interleukins 1α and 6) from the skin using the device was demonstrated. The results were verified using conventional enzyme-linked immunosorbent assays. The detection limit of the microneedle device, at ≤10 pg/mL, was at least comparable to conventional plate-based solid-phase enzyme immunoassays.