47 resultados para Imperfect maintenance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A parallel interference cancellation (PIC) detection scheme is proposed to suppress the impact of imperfect synchronisation. By treating as interference the extra components in the received signal caused by timing misalignment, the PIC detector not only offers much improved performance but also retains a low structural and computational complexity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the impact of imperfect synchronisation on D-STBC when combined with incremental relay. To suppress such an impact, a novel detection scheme is proposed, which retains the two key features of the STBC principle: simplicity (i.e. linear computational complexity), and optimality (i.e. maximum likelihood). These two features make the new detector very suitable for low power wireless networks (e.g. sensor networks).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most research on D-STBC has assumed that cooperative relay nodes are perfectly synchronised. Since such an assumption is difficult to achieve in many practical systems, this paper proposes a simple yet optimum detector for the case of two relay nodes, which proves to be much more robust against timing misalignment than the conventional STBC detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most research on distributed space time block coding (STBC) has so far focused on the case of 2 relay nodes and assumed that the relay nodes are perfectly synchronised at the symbol level. By applying STBC to 3-or 4-relay node systems, this paper shows that imperfect synchronisation causes significant performance degradation to the conventional detector. To this end, we propose a new STBC detection solution based on the principle of parallel interference cancellation (PIC). The PIC detector is moderate in computational complexity but is very effective in suppressing the impact of imperfect synchronisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A parallel interference cancellation (PIC) detection scheme is proposed to suppress the impact of imperfect synchronisation. By treating as interference the extra components in the received signal caused by timing misalignment, the PIC detector not only offers much improved performance but also retains a low structural and computational complexity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Significant performance gain can potentially be achieved by employing distributed space-time block coding (D-STBC) in ad hoc or mesh networks. So far, however, most research on D-STBC has assumed that cooperative relay nodes are perfectly synchronized. Considering the difficulty in meeting such an assumption in many practical systems, this paper proposes a simple and near-optimum detection scheme for the case of two relay nodes, which proves to be able to handle far greater timing misalignment than the conventional STBC detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – The purpose of this paper is to present the findings and lessons learned from three case studies conducted for facilities located in California, North America. The findings aim to focus on energy and maintenance management practices and the interdependent link between energy and maintenance. Design/methodology/approach – The research is based on a positivist epistemological philosophical approach informed by action research. The research cycle was completed for each case study. A case study report was provided to each facility management team to foster collaboration with the researcher and to document case study process and results. Findings – Composite findings of the case studies include: there is an interdependent link between energy and maintenance management; reactive maintenance and energy management methods are commonly used; and more proactively operated and managed buildings require the interdependent link between energy maintenance management to be better understood. Research limitations/implications – The three case studies were located in California. Although the case study results can be generalized, determination of how to generalize and apply the results to commercial buildings outside of the USA is beyond the scope of this paper. Practical implications – Detailed discussion of the needs of the three facility management teams are discussed by identifying a current challenge, developing a solution and documenting lessons learned using the research cycle. Originality/value – The paper seeks to demonstrate the interdependencies of energy and maintenance management, two topics which are often researched interdependently. Additionally, the paper provides insight about maintenance management, a topic often cited as being under researched.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aircraft Maintenance, Repair and Overhaul (MRO) feedback commonly includes an engineer’s complex text-based inspection report. Capturing and normalizing the content of these textual descriptions is vital to cost and quality benchmarking, and provides information to facilitate continuous improvement of MRO process and analytics. As data analysis and mining tools requires highly normalized data, raw textual data is inadequate. This paper offers a textual-mining solution to efficiently analyse bulk textual feedback data. Despite replacement of the same parts and/or sub-parts, the actual service cost for the same repair is often distinctly different from similar previously jobs. Regular expression algorithms were incorporated with an aircraft MRO glossary dictionary in order to help provide additional information concerning the reason for cost variation. Professional terms and conventions were included within the dictionary to avoid ambiguity and improve the outcome of the result. Testing results show that most descriptive inspection reports can be appropriately interpreted, allowing extraction of highly normalized data. This additional normalized data strongly supports data analysis and data mining, whilst also increasing the accuracy of future quotation costing. This solution has been effectively used by a large aircraft MRO agency with positive results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although much has been written about the effect on services of public sector restructuring, little is yet available on public leisure provision. This omission is addressed by considering how the delivery of public leisure services in Britain has been affected by the imposition of Compulsory Competitive Tendering (CCT). In particular, it focuses on the changing relationship between the central and local levels of government recognising, on the part of local government, a continuum of structural responses to central initiatives which have, in some cases, conspired to reduce the impact of CCT on public leisure provision. The paper concludes that although attempts have been made to protect local services, the outcome of the CCT process has been the regeneration of public leisure provision away from its service roots, but within an enduring ideological paradigm of conservative professionalism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Until the law was amended in 1984, the tenants of agricultural holdings enjoyed security of tenure for life, plus the prospect of two family successions to their tenancies, virtually guaranteeing a tenant- farming family at least three generations occupation of a holding. The orthodox view has been that any transfers of interests that took place before the passing of the Act which introduced the scheme in 1976 would not count towards the inherent 'totting-up' process. The 1993 High Court judgement in Saunders v Ralph has raised serious questions as to the validity of that assertion. This paper seeks to identify the key legal provisions involved and to highlight the problems that may result from the case.