28 resultados para GPS monitor aerospace
Resumo:
Previous studies have reported that cheese curd syneresis kinetics can be monitored by dilution of chemical tracers, such as Blue Dextran, in whey. The objective of this study was to evaluate an improved tracer method to monitor whey volumes expelled over time during syneresis. Two experiments with different ranges of milk fat (0-5% and 2.3-3.5%) were carried out in an 11 L double-O laboratory scale cheese vat. Tracer was added to the curd-whey mixture during the cutting phase of cheese making and samples were taken at 10 min intervals up to 75 min after cutting. The volume of whey expelled was measured gravimetrically and the dilution of tracer in the whey was measured by absorbance at 620 nm. The volumes of whey expelled were significantly reduced at higher milk fat levels. Whey yield was predicted with a SEP ranging from 3.2 to 6.3 g whey/100 mL of milk and a CV ranging from 2.03 to 2.7% at different milk fat levels.
Resumo:
There is growing interest in the ways in which the location of a person can be utilized by new applications and services. Recent advances in mobile technologies have meant that the technical capability to record and transmit location data for processing is appearing in off-the-shelf handsets. This opens possibilities to profile people based on the places they visit, people they associate with, or other aspects of their complex routines determined through persistent tracking. It is possible that services offering customized information based on the results of such behavioral profiling could become commonplace. However, it may not be immediately apparent to the user that a wealth of information about them, potentially unrelated to the service, can be revealed. Further issues occur if the user agreed, while subscribing to the service, for data to be passed to third parties where it may be used to their detriment. Here, we report in detail on a short case study tracking four people, in three European member states, persistently for six weeks using mobile handsets. The GPS locations of these people have been mined to reveal places of interest and to create simple profiles. The information drawn from the profiling activity ranges from intuitive through special cases to insightful. In this paper, these results and further extensions to the technology are considered in light of European legislation to assess the privacy implications of this emerging technology.
Resumo:
This is the first in a short series of articles that focus on what GPs should consider when monitoring and prescribing specialist-initiated palliative-care drugs. This first article summarises the key issues for patients receiving ketamine.
Resumo:
Surface-based GPS measurements of zenith path delay (ZPD) can be used to derive vertically integrated water vapor (IWV) of the atmosphere. ZPD data are collected in a global network presently consisting of 160 stations as part of the International GPS Service. In the present study, ZPD data from this network are converted into IWV using observed surface pressure and mean atmospheric water vapor column temperature obtained from the European Centre for Medium-Range Weather Forecasts' (ECMWF) operational analyses (OA). For the 4 months of January/July 2000/2001, the GPS-derived IWV values are compared to the IWV from the ECMWF OA, with a special focus on the monthly averaged difference (bias) and the standard deviation of daily differences. This comparison shows that the GPS-derived IWV values are well suited for the validation of OA of IWV. For most GPS stations, the IWV data agree quite well with the analyzed data indicating that they are both correct at these locations. Larger differences for individual days are interpreted as errors in the analyses. A dry bias in the winter is found over central United States, Canada, and central Siberia, suggesting a systematic analysis error. Larger differences were mainly found in mountain areas. These were related to representation problems and interpolation difficulties between model height and station height. In addition, the IWV comparison can be used to identify errors or problems in the observations of ZPD. This includes errors in the data itself, e.g., erroneous outlier in the measured time series, as well as systematic errors that affect all IWV values at a specific station. Such stations were excluded from the intercomparison. Finally, long-term requirements for a GPS-based water vapor monitoring system are discussed.
Resumo:
This is the second in a short series of articles that focus on what GPs should consider when monitoring and prescribing specialist‐initiated palliative‐care drugs. Here, the authors summarise the key issues around the use of methadone for pain management.
Resumo:
The Mediterranean is an important eco-region, however, it suffers from the lack of common procedures for the management and monitoring of its protected areas sustainability. The INNOVA project addresses this issue by developing a procedure namely PASEMP as well as tools which can assist Protected Areas Managers and responsible authorities to develop and implement a monitoring strategy for their areas. This handbook is proposed as a flexible tool, or a reference text which should be used in combination with the PASEMP guidelines to identify indicators, but also contains guidance on how to implement and report the monitoring strategy results.
Resumo:
Producing according to enhanced farm animal welfare (FAW) standards increases costs along the livestock value chain, especially for monitoring certified animal friendly products. In the choice between public or private bodies for carrying out and monitoring certification, consumer preferences and trust play a role. We explore this issue by applying logit analysis involving socio-economic and psychometric variables to survey data from Italy. Results identify marked consumer preferences for public bodies and trust in stakeholders a key determinant.
Resumo:
We present one of the first studies of the use of Distributed Temperature Sensing (DTS) along fibre-optic cables to purposely monitor spatial and temporal variations in ground surface temperature (GST) and soil temperature, and provide an estimate of the heat flux at the base of the canopy layer and in the soil. Our field site was at a groundwater-fed wet meadow in the Netherlands covered by a canopy layer (between 0-0.5 m thickness) consisting of grass and sedges. At this site, we ran a single cable across the surface in parallel 40 m sections spaced by 2 m, to create a 40×40 m monitoring field for GST. We also buried a short length (≈10 m) of cable to depth of 0.1±0.02 m to measure soil temperature. We monitored the temperature along the entire cable continuously over a two-day period and captured the diurnal course of GST, and how it was affected by rainfall and canopy structure. The diurnal GST range, as observed by the DTS system, varied between 20.94 and 35.08◦C; precipitation events acted to suppress the range of GST. The spatial distribution of GST correlated with canopy vegetation height during both day and night. Using estimates of thermal inertia, combined with a harmonic analysis of GST and soil temperature, substrate and soil-heat fluxes were determined. Our observations demonstrate how the use of DTS shows great promise in better characterising area-average substrate/soil heat flux, their spatiotemporal variability, and how this variability is affected by canopy structure. The DTS system is able to provide a much richer data set than could be obtained from point temperature sensors. Furthermore, substrate heat fluxes derived from GST measurements may be able to provide improved closure of the land surface energy balance in micrometeorological field studies. This will enhance our understanding of how hydrometeorological processes interact with near-surface heat fluxes.