21 resultados para Determination of aluminium in water


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The coadsorption of water with organic molecules under near-ambient pressure and temperature conditions opens up new reaction pathways on model catalyst surfaces that are not accessible in conventional ultrahigh-vacuum surfacescience experiments. The surface chemistry of glycine and alanine at the water-exposed Cu{110} interface was studied in situ using ambient-pressure photoemission and X-ray absorption spectroscopy techniques. At water pressures above 10-5 Torr a significant pressure-dependent decrease in the temperature for dissociative desorption was observed for both amino acids, accompanied by the appearance of a newCN intermediate, which is not observed for lower pressures. The most likely reaction mechanisms involve dehydrogenation induced by O and/or OH surface species resulting from the dissociative adsorption of water. The linear relationship between the inverse decomposition temperature and the logarithm of water pressure enables determination of the activation energy for the surface reaction, between 213 and 232 kJ/mol, and a prediction of the decomposition temperature at the solidliquid interface by extrapolating toward the equilibrium vapor pressure. Such experiments near the equilibrium vapor pressure provide important information about elementary surface processes at the solidliquid interface, which can be retrieved neither under ultrahigh vacuum conditions nor from interfaces immersed in a solution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the synthesis and characterisation of tetrakis(2,4,6-triisopropylphenyl)diphosphine. Synthesis is effected by the treatment of PCl3 with an excess of 2,4,6-triisopropylphenyllithium (or the equivalent Grignard reagent) in 70% yield. While under normal circumstances the triarylphosphine would be expected, excessive bulk prevents this, and the resulting diphosphine is, unusually, stable to PP cleavage by further organolithium moieties. The compound is stable, both thermally (m.p. 185°C) and to air and water in the solid state, although conversion to the equivalent diorganophosphinate ester is effected by boiling ethanolic solutions in air. Crystallisation from hexane/ethanol afforded pale yellow crystals of X-ray quality. The molecule is characterised by m.p., IR, NMR, elemental analysis (C, H, P) and MS. The X-ray structure shows an antiperiplanar conformation with a PP separation of 2.2461(16) Å. Comparisons are made with other diphosphines, the title compound being only the fourth simple diphosphine to be structurally characterised.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper examines two hydrochemical time-series derived from stream samples taken in the Upper Hafren catchment, Plynlimon, Wales. One time-series comprises data collected at 7-hour intervals over 22 months (Neal et al., submitted, this issue), while the other is based on weekly sampling over 20 years. A subset of determinands: aluminium, calcium, chloride, conductivity, dissolved organic carbon, iron, nitrate, pH, silicon and sulphate are examined within a framework of non-stationary time-series analysis to identify determinand trends, seasonality and short-term dynamics. The results demonstrate that both long-term and high-frequency monitoring provide valuable and unique insights into the hydrochemistry of a catchment. The long-term data allowed analysis of long-termtrends, demonstrating continued increases in DOC concentrations accompanied by declining SO4 concentrations within the stream, and provided new insights into the changing amplitude and phase of the seasonality of the determinands such as DOC and Al. Additionally, these data proved invaluable for placing the short-term variability demonstrated within the high-frequency data within context. The 7-hour data highlighted complex diurnal cycles for NO3, Ca and Fe with cycles displaying changes in phase and amplitude on a seasonal basis. The high-frequency data also demonstrated the need to consider the impact that the time of sample collection can have on the summary statistics of the data and also that sampling during the hours of darkness provides additional hydrochemical information for determinands which exhibit pronounced diurnal variability. Moving forward, this research demonstrates the need for both long-term and high-frequency monitoring to facilitate a full and accurate understanding of catchment hydrochemical dynamics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the absence of a suitable method for routine analysis of large numbers of natural river water samples for organic nitrogen and phosphorus fractions, a new simultaneous digestion technique was developed, based on a standard persulphate digestion procedure. This allows rapid analysis of river, lake and groundwater samples from a range of environments for total nitrogen and phosphorus. The method was evaluated using a range of organic nitrogen and phosphorus structures tested at low, mid and high range concentrations from 2 to 50 mg l-1 nitrogen and 0.2 to 10 mg l-1 phosphorus. Mean recoveries for nitrogen ranged from 94.5% (2 mg I-1) to 92.7% (50 mg I-1) and for phosphorus were 98.2% (0.2 mg l-1) to 100.2% (10 mg l-1). The method is precise in its ability m reproduce results from replicate digestions, and robust in its ability to handle a variety of natural water samples in the pH range 5-8.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

From the concentrations of dissolved atmospheric noble gases in water, a so-called “noble gas temperature” (NGT) can be determined that corresponds to the temperature of the water when it was last in contact with the atmosphere. Here we demonstrate that the NGT concept is applicable to water inclusions in cave stalagmites, and yields NGTs that are in good agreement with the ambient air temperatures in the caves. We analysed samples from two Holocene and one undated stalagmite. The three stalagmites originate from three caves located in different climatic regions having modern mean annual air temperatures of 27 °C, 12 °C and 8 °C, respectively. In about half of the samples analysed Kr and Xe concentrations originated entirely from the two well-defined noble gas components air-saturated water and atmospheric air, which allowed NGTs to be determined successfully from Kr and Xe concentrations. One stalagmite seems to be particularly suitable for NGT determination, as almost all of its samples yielded the modern cave temperature. Notably, this stalagmite contains a high proportion of primary water inclusions, which seem to preserve the temperature-dependent signature well in their Kr and Xe concentrations. In future work on stalagmites detailed microscopic inspection of the fluid inclusions prior to noble gas analysis is therefore likely to be crucial in increasing the number of successful NGT determinations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surface-based GPS measurements of zenith path delay (ZPD) can be used to derive vertically integrated water vapor (IWV) of the atmosphere. ZPD data are collected in a global network presently consisting of 160 stations as part of the International GPS Service. In the present study, ZPD data from this network are converted into IWV using observed surface pressure and mean atmospheric water vapor column temperature obtained from the European Centre for Medium-Range Weather Forecasts' (ECMWF) operational analyses (OA). For the 4 months of January/July 2000/2001, the GPS-derived IWV values are compared to the IWV from the ECMWF OA, with a special focus on the monthly averaged difference (bias) and the standard deviation of daily differences. This comparison shows that the GPS-derived IWV values are well suited for the validation of OA of IWV. For most GPS stations, the IWV data agree quite well with the analyzed data indicating that they are both correct at these locations. Larger differences for individual days are interpreted as errors in the analyses. A dry bias in the winter is found over central United States, Canada, and central Siberia, suggesting a systematic analysis error. Larger differences were mainly found in mountain areas. These were related to representation problems and interpolation difficulties between model height and station height. In addition, the IWV comparison can be used to identify errors or problems in the observations of ZPD. This includes errors in the data itself, e.g., erroneous outlier in the measured time series, as well as systematic errors that affect all IWV values at a specific station. Such stations were excluded from the intercomparison. Finally, long-term requirements for a GPS-based water vapor monitoring system are discussed.