42 resultados para Armer, Chip


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The recent discovery that vitamin E (VE) regulates gene activity at the transcriptional level indicates that VE may exert part of its biological effects by mechanisms which may be independent of its well-recognised antioxidant function. The objective of this study was the identification of hepatic vitamin E-sensitive genes and examination of the effects of VE on their corresponding biological endpoints. Two groups of male rats were randomly assigned to either a VE-sufficient diet or to a control diet deficient in VE for 290 days. High-density oligonucleotide microarrays comprising over 7000 genes were used to assess the transcriptional response of the liver. Differential gene expression was monitored over a period of 9 months, at four different time-points, and rats were individually profiled. This experimental strategy identified several VE-sensitive genes, which were chronically altered by dietary VE. VE supplementation down-regulated scavenger receptor CD36, coagulation factor IX and 5-alpha-steroid reductase type 1 mRNA levels while hepatic gamma glutamyl-cysteinyl synthetase was significantly up-regulated. Measurement of the corresponding biological endpoints such as activated partial thromboplastin time, plasma dihydrotestosterone and hepatic glutathione substantiated the gene chip data which indicated that dietary VE plays an important role in a range of metabolic processes within the liver. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pullpipelining, a pipeline technique where data is pulled from successor stages from predecessor stages is proposed Control circuits using a synchronous, a semi-synchronous and an asynchronous approach are given. Simulation examples for a DLX generic RISC datapath show that common control pipeline circuit overhead is avoided using the proposal. Applications to linear systolic arrays in cases when computation is finished at early stages in the array are foreseen. This would allow run-time data-driven digital frequency modulation of synchronous pipelined designs. This has applications to implement algorithms exhibiting average-case processing time using a synchronous approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the design, implementation and synthesis of an FFT module that has been specifically optimized for use in the OFDM based Multiband UWB system, although the work is generally applicable to many other OFDM based receiver systems. Previous work has detailed the requirements for the receiver FFT module within the Multiband UWB ODFM based system and this paper draws on those requirements coupled with modern digital architecture principles and low power design criteria to converge on our optimized solution. The FFT design obtained in this paper is also applicable for implementation of the transmitter IFFT module therefore only needing one FFT module for half-duplex operation. The results from this paper enable the baseband designers of the 200Mbit/sec variant of Multiband UWB systems (and indeed other OFDM based receivers) using System-on-Chip (SoC), FPGA and ASIC technology to create cost effective and low power solutions biased toward the competitive consumer electronics market.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the architectural design, implementation and associated simulated peformance results of a possible receiver solution fir a multiband Ultra-Wideband (UWB) receiver. The paper concentrates on the tradeoff between the soft-bit width and numerical precision requirements for the receiver versus performance. The required numerical precision results obtained in this paper can be used by baseband designers of cost effective UWB systems using Systein-on-Chip (SoC), FPGA and ASIC technology solutions biased toward the competitive consumer electronics market(1).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the design, implementation and synthesis of an FFT module that has been specifically optimized for use in the OFDM based Multiband UWB system, although the work is generally applicable to many other OFDM based receiver systems. Previous work has detailed the requirements for the receiver FFT module within the Multiband UWB ODFM based system and this paper draws on those requirements coupled with modern digital architecture principles and low power design criteria to converge on our optimized solution particularly aimed at a low-clock rate implementation. The FFT design obtained in this paper is also applicable for implementation of the transmitter IFFT module therefore only needing one FFT module in the device for half-duplex operation. The results from this paper enable the baseband designers of the 200Mbit/sec variant of Multiband UWB systems (and indeed other OFDM based receivers) using System-on-Chip (SoC), FPGA and ASIC technology to create cost effective and low power consumer electronics product solutions biased toward the very competitive market.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the requirements on the numerical precision for a practical Multiband Ultra-Wideband (UWB) consumer electronic solution. To this end we first present the possibilities that UWB has to offer to the consumer electronics market and the possible range of devices. We then show the performance of a model of the UWB baseband system implemented using floating point precision. Then, by simulation we find the minimal numerical precision required to maintain floating-point performance for each of the specific data types and signals present in the UWB baseband. Finally, we present a full description of the numerical requirements for both the transmit and receive components of the UWB baseband. The numerical precision results obtained in this paper can then be used by baseband designers to implement cost effective UWB systems using System-on-Chip (SoC), FPGA and ASIC technology solutions biased toward the competitive consumer electronics market(1).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

I was born human. But this was an accident of fate - a condition merely of time and place. I believe it's something we have the power to change. I will tell you why. In August 1998, a silicon chip was implanted in my arm, allowing a computer to monitor me as I moved through the halls and offices of the Department of Cybernetics at the University of Reading, just west of London, where I've been a professor since 1988. My implant communicated via radio waves with a network of antennas throughout the department that in turn transmitted the signals to a computer programmed to respond to my actions. At the main entrance, a voice box operated by the computer said "Hello" when I entered; the computer detected my progress through the building, opening the door to my lab for me as I approached it and switching on the lights. For the nine days the implant was in place, I performed seemingly magical acts simply by walking in a particular direction. The aim of this experiment was to determine whether information could be transmitted to and from an implant. Not only did we succeed, but the trial demonstrated how the principles behind cybernetics could perform in real-life applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multi-rate multicarrier DS/CDMA is a potentially attractive multiple access method for future wireless communications networks that must support multimedia, and thus multi-rate, traffic. Several receiver structures exist for single-rate multicarrier systems, but little has been reported on multi-rate multicarrier systems. Considering that high-performance detection such as coherent demodulation needs the explicit knowledge of the channel, based on the finite-length chip waveform truncation, this paper proposes a subspace-based scheme for timing and channel estimation in multi-rate multicarrier DS/CDMA systems, which is applicable to both multicode and variable spreading factor systems. The performance of the proposed scheme for these two multi-rate systems is validated via numerical simulations. The effects of the finite-length chip waveform truncation on the performance of the proposed scheme is also analyzed theoretically.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this book is to provide and introduction to microprocessor systems, their operation and design. It covers those topics needed by engineers and computer scientists who are interested in applying microprocessors in practical situations, namely computer hardware including logic and interfacing, software, in particular high level and assembly language programming, and the design and testing of such systems. The fundamental principles of micrprocessor systems are described and these are illustrated with reference to two microprocessors, the 32-bit MC68020 from Motorola and a single chip microcomputer, the 8051 from Intel; and in addition, interfacing to the general purpose STE bus is described. The details of the processors and the bus are concentrated in three chapters, thus allowing the presentation of the material to be independent of the microprocessors if that is desired, and permitting the specific details to be found easily.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Schottky barrier diodes have been integrated into on-chip rectangular waveguides. Two novel techniques have been developed to fabricate diodes with posts suitable for integration into waveguides. One technique produces diodes with anode diameters of the order of microns with post heights from 90 to 125 microns and the second technique produces sub-micron anodes with post heights around 20 microns. A method has been developed to incorporate these structures into a rectangular waveguide and provide a top contact onto the anode which could be used as an I.F. output in a mixer circuit. Devices have been fabricated and D.C. characterized.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new technique is reported for micro-machining millimetre-wave rectangular waveguide components. S-parameter measurements on these structures show that they achieve lower loss than those produced using any other on-chip fabrication technique, have highly accurate dimensions, are physically robust, and are cheap and easy to manufacture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a simple device for multiplex quantitative enzyme-linked immunosorbant assays (ELISA) made from a novel melt-extruded microcapillary film (MCF) containing a parallel array of 200µm capillaries along its length. To make ELISA devices different protein antigens or antibodies were immobilised inside individual microcapillaries within long reels of MCF extruded from fluorinated ethylene propylene (FEP). Short pieces of coated film were cut and interfaced with a pipette, allowing sequential uptake of samples and detection solutions into all capillaries from a reagent well. As well as being simple to produce, these FEP MCF devices have excellent light transmittance allowing direct optical interrogation of the capillaries for simple signal quantification. Proof of concept experiments demonstrate both quantitative and multiplex assays in FEP MCF devices using a standard direct ELISA procedure and read using a flatbed scanner. This new multiplex immunoassay platform should find applications ranging from lab detection to point-of-care and field diagnostics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A parallel processor architecture based on a communicating sequential processor chip, the transputer, is described. The architecture is easily linearly extensible to enable separate functions to be included in the controller. To demonstrate the power of the resulting controller some experimental results are presented comparing PID and full inverse dynamics on the first three joints of a Puma 560 robot. Also examined are some of the sample rate issues raised by the asynchronous updating of inertial parameters, and the need for full inverse dynamics at every sample interval is questioned.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To investigate the occurrence of antimicrobial resistance genes of human clinical relevance in Salmonella isolated from livestock in Great Britain. Two hundred and twenty-five Salmonella enterica isolates were characterized using an antimicrobial resistance gene chip and disc diffusion assays. Plasmid profiling, conjugation experiments and identification of Salmonella genomic island 1 (SGI1) were performed for selected isolates. Approximately 43% of Salmonella harboured single or multiple antimicrobial resistance genes with pig isolates showing the highest numbers where 96% of Salmonella Typhimurium harboured one or more resistance genes. Isolates harbouring multiple resistances divided into three groups. Group 1 isolates harboured ampicillin/streptomycin/sulphonamide/tetracycline resistance and similar phenotypes. This group contained isolates from pigs, cattle and poultry that were from several serovars including Typhimurium, 4,[5],12:i:-, Derby, Ohio and Indiana. All Group 2 isolates were from pigs and were Salmonella Typhimurium. They contained a non-sul-type class 1 integron and up to 13 transferrable resistances. All Group 3 isolates harboured a class 1 integron and were isolated from all animal species included in the study. Most isolates were Salmonella Typhimurium and harboured SGI1. Salmonella isolated from livestock was shown to harbour antimicrobial resistance genes although no or little resistance to third-generation cephalosporins or ciprofloxacin, respectively, was detected. The preponderance in pigs of multidrug-resistant Salmonella Typhimurium makes it important to introduce control measures such as improved biosecurity to ensure that they do not pass through the food chain and limit human therapeutic options.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The layer-by-layer deposition of polymers onto surfaces allows the fabrication of multilayered materials for a wide range of applications, from drug delivery to biosensors. This work describes the analysis of complex formation between poly(acrylic acid) and methylcellulose in aqueous solutions using Biacore, a surface plasmon resonance analytical technique, traditionally used to examine biological interactions. This technique characterized the layer-by-layer deposition of these polymers on the surface of a Biacore sensor chip. The results were subsequently used to optimize the experimental conditions for sequential layer deposition on glass slides. The role of the solution pH and poly(acrylic acid) molecular weight on the formation of interpolymer multilayered coatings was researched, and showed that the optimal deposition of the polymer complexes was achieved at pHs ≤2.5 with a poly(acrylic acid) molecular weight of 450 kDa.