21 resultados para Accelerated Solvent Extraction (Dionex ASE)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple parallel synthesis and evaluation have been combined in order to identify new nitrogen heterocycles for the partitioning of minor actinides(III) such as americium(III) from lanthanides such as europium(Ill). An array of triazine-containing molecules was made using multiple parallel syntheses from diketones and amide hydrazides. An excess of each of the resulting purified reagents was dissolved in 1,1,2,2-tetrachloroethane containing 2-bromodecanoic acid, and equilibrated with an aqueous solution containing the radiotracers Eu-152 and Am-241 in nitric acid ([Eu] + [Am] < 400 nanomol dm(-3)). Gamma counting of the organic and aqueous phases led to the identification of several new reagents for the selective extraction of americium(III). In particular, 6-(2-pyridyl)-2-(5,6-dialkyl-1,2,4-triazaphenyl)pyridines were found to be effective reagents for the separation of americium(III) from europium(III), (SFAm/Eu was ca. 30 in [HNO3] = 0.013 mol/L).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Templated sol-gel encapsulation of surfactant-stabilised micelles containing metal precursor(s) with ultra-thin porous silica coating allows solvent extraction of organic based stabiliser from the composites in colloidal state hence a new method of preparing supported alloy catalysts using the inorganic silica-stabilised nano-sized, homogenously mixed, silver - platinum (Ag-Pt) colloidal particles is reported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method is described for the analysis of deuterated and undeuterated alpha-tocopherol in blood components using liquid chromatography coupled to an orthogonal acceleration time-of-flight (TOF) mass spectrometer. Optimal ionisation conditions for undeuterated (d0) and tri- and hexadeuterated (d3 or d6) alpha-tocopherol standards were found with negative ion mode electrospray ionisation. Each species produced an isotopically resolved single ion of exact mass. Calibration curves of pure standards were linear in the range tested (0-1.5 muM, 0-15 pmol injected). For quantification of d0 and d6 in blood components following a standard solvent extraction, a stable-isotope-labelled internal standard (d3-alpha-tocopherol) was employed. To counter matrix ion suppression effects, standard response curves were generated following identical solvent extraction procedures to those of the samples. Within-day and between-day precision were determined for quantification of d0- and d6-labelled alpha-tocopherol in each blood component and both averaged 3-10%. Accuracy was assessed by comparison with a standard high-performance liquid chromatography (HPLC) method, achieving good correlation (r(2) = 0.94), and by spiking with known concentrations of alpha-tocopherol (98% accuracy). Limits of detection and quantification were determined to be 5 and 50 fmol injected, respectively. The assay was used to measure the appearance and disappearance of deuterium-labelled alpha-tocopherol in human blood components following deuterium-labelled (d6) RRR-alpha-tocopheryl acetate ingestion. The new LC/TOFMS method was found to be sensitive, required small sample volumes, was reproducible and robust, and was capable of high throughput when large numbers of samples were generated. Copyright (C) 2003 John Wiley Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The synthesis and extraction of americium(III) and europium(III) from aqueous nitric acid solutions by the new BTBP ligands 6,6’-bis(5,5,7,7- tetramethyl-5,7-dihydrofuro[3,4-e]-1,2,4-triazin-3-yl)-2,2’-bipyridine (Cy5-O-Me4-BTBP), and 6,6’-bis(5,5,7,7-tetramethyl-5,7-dihydrothieno[3,4-e]-1,2,4-triazin-3-yl)- 2,2’-bipyridine (Cy5-S-Me4-BTBP) is described. The affinity for Am(III) and the selectivity for Am(III) over Eu(III) of Cy5-S-Me4-BTBP were generally higher than for Cy5-O-Me4-BTBP. For both ligands, the extraction of Am(III) and Eu(III) from 3 M HNO3 into 3 mM organic solutions varied with the diluent used. The highest distribution ratios and separation factors observed were in cyclohexanone and 2-methylcyclohexanone, respectively. For Cy5-S-Me4-BTBP, there is a strong correlation between the distribution ratio for Am(III) and the permittivity of the diluent used. With 1-octanol as the diluent, low distribution ratios (D(Am) < 1) were observed for Cy5-S-Me4-BTBP although this ligand extracts Am(III) selectively (SFAm/Eu = 16-46 from 1-4 M HNO3). For Cy5-S-Me4-BTBP, Am(III) is extracted as the disolvate. The distribution ratios for Am(III), and the separation factors for Am(III) over Eu(III) are both significantly higher for CyMe4-BTBP than they are for Cy5-O-Me4-BTBP and Cy5-S-Me4-BTBP in cyclohexanone. Changing the diluent from cyclohexanone to 2-methylcyclohexanone leads to a decrease in D(Am) but an increase in SFAm/Eu for Cy5-S-Me4-BTBP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quadridentate N-heterocyclic ligand 6-(5,5,8,8-tetramethyl-5,6,7,8-tetrahydro-1,2,4-benzotriazin- 3-yl)-2,2′ : 6′,2′′-terpyridine (CyMe4-hemi-BTBP) has been synthesized and its interactions with Am(III),U(VI), Ln(III) and some transition metal cations have been evaluated by X-ray crystallographic analysis, Am(III)/Eu(III) solvent extraction experiments, UVabsorption spectrophotometry, NMR studies and ESI-MS. Structures of 1 : 1 complexes with Eu(III), Ce(III) and the linear uranyl (UO2 2+) ion were obtained by X-ray crystallographic analysis, and they showed similar coordination behavior to related BTBP complexes. In methanol, the stability constants of the Ln(III) complexes are slightly lower than those of the analogous quadridentate bis-triazine BTBP ligands, while the stability constant for the Yb(III)complex is higher. 1H NMR titrations and ESI-MS with lanthanide nitrates showed that the ligand forms only 1 : 1 complexes with Eu(III), Ce(III) and Yb(III), while both 1 : 1 and 1 : 2 complexes were formed with La(III) and Y(III) in acetonitrile. A mixture of isomeric chiral 2 : 2 helical complexes was formed with Cu(I), with a slight preference (1.4 : 1) for a single directional isomer. In contrast, a 1 : 1 complex was observed with the larger Ag(I) ion. The ligand was unable to extract Am(III) or Eu(III) from nitric acid solutions into 1-octanol, except in the presence of a synergist at low acidity. The results show that the presence of two outer 1,2,4-triazine rings is required for the efficient extraction and separation of An(III)from Ln(III) by quadridentate N-donor ligands.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The removal of the most long-lived radiotoxic elements from used nuclear fuel, minor actinides, is foreseen as an essential step toward increasing the public acceptance of nuclear energy as a key component of a low-carbon energy future. Once removed from the remaining used fuel, these elements can be used as fuel in their own right in fast reactors or converted into shorter-lived or stable elements by transmutation prior to geological disposal. The SANEX process is proposed to carry out this selective separation by solvent extraction. Recent efforts to develop reagents capable of separating the radioactive minor actinides from lanthanides as part of a future strategy for the management and reprocessing of used nuclear fuel are reviewed. The current strategies for the reprocessing of PUREX raffinate are summarized, and some guiding principles for the design of actinide-selective reagents are defined. The development and testing of different classes of solvent extraction reagent are then summarized, covering some of the earliest ligand designs right through to the current reagents of choice, bis(1,2,4-triazine) ligands. Finally, we summarize research aimed at developing a fundamental understanding of the underlying reasons for the excellent extraction capabilities and high actinide/lanthanide selectivities shown by this class of ligands and our recent efforts to immobilize these reagents onto solid phases.