Demands for thermal comfort, better indoor air quality together with lower environmental impacts have had ascending trends in the last decade. In many circumstances, these demands could not be fully covered through the soft approach of bioclimatic design like optimisation of the building orientation and internal layout. This is mostly because of the dense urban environment and building internal energy loads. In such cases, heating, ventilation, air-conditioning and refrigeration (HVAC&R) systems make a key role to fulfill the requirements of indoor environment. Therefore, it is required to select the most proper HVAC&R system. In this study, a robust decision making approach for HVAC&R system selection is proposed. Technical performance, economic aspect and environmental impacts of 36 permutations of primary and secondary systems are taken into account to choose the most proper HVAC&R system for a case study office building. The building is a representative for the dominant form of office buildings in the UK. Dynamic performance evaluation of HVAC&R alternatives using TRNSYS package together with life cycle energy cost analysis provides a reliable basis for decision making. Six scenarios broadly cover the decision makers' attitudes on HVAC&R system selection which are analysed through Analytical Hierarchy Process (AHP). One of the significant outcomes reveals that, despite both the higher energy demand and more investment requirements associated with compound heating, cooling and power system (CCHP); this system is one of the top ranked alternatives due to the lower energy cost and C02 emissions. The sensitivity analysis reveals that in all six scenarios, the first five top ranked alternatives are not changed. Finally, the proposed approach and the results could be used by researchers and designers especially in the early stages of a design process in which all involved bodies face the lack of time, information and tools for evaluation of a variety of systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Existing buildings contribute greatly to global energy use and greenhouse gas emissions. In the UK, about 18% of carbon emissions are generated by non-domestic buildings; sustainable building refurbishment can play an important role in reducing carbon emissions. This paper looks at the performance of a recently refurbished 5-storey office building in London, in terms of energy consumption as well as occupants’ satisfaction. Pre- and post-occupancy evaluation studies were conducted using online questionnaire surveys and energy consumption evaluation. Results from pre-occupancy and post-occupancy evaluation studies showed that employees, in general, were more satisfied with their work environment at the refurbished building than with that of their previous office. Employees’ self-reported productivity improved after the move to Elms House. These surveys showed a positive relationship between employees’ satisfaction with their work environment and their self-reported productivity, well-being and enjoyment at work. The factor that contributed to increasing employee satisfaction the most was: better use of interior space. Although the refurbishment was a success in terms of reducing energy consumption per m2, the performance gap was almost 3 times greater than that estimated. Unregulated loads, problems with building control, ineffective use of space and occupants’ behaviour are argued to be reasons for this gap.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In an attempt to focus clients' minds on the importance of considering the construction and maintenance costs of a commercial office building (both as a factor in staff productivity and as a fraction of lifetime staff costs) there is an often-quoted ratio of costs of 1:5:200, where for every one pound spent on construction cost, five are spent on maintenance and building operating costs and 200 on staffing and business operating costs. This seems to stem from a paper published by the Royal Academy of Engineering, in which no data is given and no derivation or defence of the ratio appears. The accompanying belief that higher quality design and construction increases staff productivity, and simultaneously reduces maintenance costs, how ever laudable, appears unsupported by research, and carries all the hallmarks of an "urban myth". In tracking down data about real buildings, a more realistic ratio appears to depend on a huge variety of variables, as well as the definition of the number of "lifetime" years. The ill-defined origins of the original ratio (1:5:200) describing these variables have made replication impossible. However, by using published sources of data, we have found that for three office buildings, a more realistic ratio is 1:0.4:12. As there is nothing in the public domain about what comprised the original research that gave rise to 1:5:200, it is not possible to make a true comparison between these new calculations and the originals. Clients and construction professionals stand to be misled because the popularity and widespread use of the wrong ratio appears to be mis-informing important investment and policy decisions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

To fully appreciate the environmental impact of an office building, the transport-related carbon dioxide (CO2) emissions resulting from its location should be considered in addition to the emissions that result from the operation of the building itself. Travel-related CO2 emissions are a function of three criteria, two of which are influenced by physical location and one of which is a function of business practice. The two spatial criteria are, first, the location of the office relative to the location of the workforce, the market, complementary business activities (and the agglomeration benefits this offers) and, second, the availability and cost of transport modes. The business criterion is the need for, and therefore frequency of, visits and this, in turn, depends on the requirement for a physically present workforce and face-to-face contact with clients. This paper examines the commuting-related CO2 emissions that result from city centre and out-of-town office locations. Using 2001 Census Special Workplace Statistics which record people’s residence, usual workplace and mode of transport between them, distance travelled and mode of travel were calculated for a sample of city centre and out-of-town office locations. The results reveal the extent of the difference between transport-related CO2 emitted by commuters to out-of-town and city centre locations. The implications that these findings have for monitoring the environmental performance of offices are discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Lighting and small power will typically account for more than half of the total electricity consumption in an office building. Significant variations in electricity used by different tenants suggest that occupants can have a significant impact on the electricity demand for these end-uses. Yet current modelling techniques fail to represent the interaction between occupant and the building environment in a realistic manner. Understanding the impact of such behaviours is crucial to improve the methodology behind current energy modelling techniques, aiming to minimise the significant gap between predicted and in-use performance of buildings. A better understanding of the impact of occupant behaviour on electricity consumption can also inform appropriate energy saving strategies focused on behavioural change. This paper reports on a study aiming to assess the intent of occupants to switch off lighting and appliances when not in use in office buildings. Based on the Theory of Planned Behaviour, the assessment takes the form of a questionnaire and investigates three predictors to behaviour individually: 1) behavioural attitude; 2) subjective norms; 3) perceived behavioural control. The paper details the development of the assessment procedure and discusses preliminary findings from the study. The questionnaire results are compared against electricity consumption data for individual zones within a multi-tenanted office building. Initial results demonstrate a statistically significant correlation between perceived behavioural control and energy consumption for lighting and small power

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The Chartered Institute of Building Service Engineers (CIBSE) produced a technical memorandum (TM36) presenting research on future climate impacting building energy use and thermal comfort. One climate projection for each of four CO2 emissions scenario were used in TM36, so providing a deterministic outlook. As part of the UK Climate Impacts Programme (UKCIP) probabilistic climate projections are being studied in relation to building energy simulation techniques. Including uncertainty in climate projections is considered an important advance to climate impacts modelling and is included in the latest UKCIP data (UKCP09). Incorporating the stochastic nature of these new climate projections in building energy modelling requires a significant increase in data handling and careful statistical interpretation of the results to provide meaningful conclusions. This paper compares the results from building energy simulations when applying deterministic and probabilistic climate data. This is based on two case study buildings: (i) a mixed-mode office building with exposed thermal mass and (ii) a mechanically ventilated, light-weight office building. Building (i) represents an energy efficient building design that provides passive and active measures to maintain thermal comfort. Building (ii) relies entirely on mechanical means for heating and cooling, with its light-weight construction raising concern over increased cooling loads in a warmer climate. Devising an effective probabilistic approach highlighted greater uncertainty in predicting building performance, depending on the type of building modelled and the performance factors under consideration. Results indicate that the range of calculated quantities depends not only on the building type but is strongly dependent on the performance parameters that are of interest. Uncertainty is likely to be particularly marked with regard to thermal comfort in naturally ventilated buildings.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper investigates whether the intrinsic energy efficiency rating of an office building has a significant impact on its rental value. A sample of 817 transactions for offices with Energy Performance Certificates (EPCs) in the UK is used to assess whether a pricing differential can be identified, depending on the energy rating. While previous analyses of this topic have typically relied on appraisal-based and/or asking rent data, the dataset used in this research contains actual contract rents as well as information on lease terms. The results indicate a significant rental premium for energy-efficient buildings. However, it is found that this premium appears to be mainly driven by the youngest cohort of state-of-the-art energy-efficient buildings. The results also show that tenants of more energy-efficient buildings tend to pay a lower service charge, but this link appears to be rather weak and limited to newer buildings. Hence, it is argued that the information contained in the EPC is still not fully taken into account in the UK commercial property market with the possible exception of both the highest and the lowest EPC ratings.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Government initiatives in several developed and developing countries to roll-out smart meters call for research on the sustainability impacts of these devices. In principle smart meters bring about higher control over energy theft and lower consumption, but require a high level of engagement by end-users. An alternative consists of load controllers, which control the load according to pre-set parameters. To date, research has focused on the impacts of these two alternatives separately. This study compares the sustainability impacts of smart meters and load controllers in an occupied office building in Italy. The assessment is carried out on three different floors of the same building. Findings show that demand reductions associated with a smart meter device are 5.2% higher than demand reductions associated with the load controller.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Thermochromic windows are able to modulate their transmittance in both the visible and the near-infrared field as a function of their temperature. As a consequence, they allow to control the solar gains in summer, thus reducing the energy needs for space cooling. However, they may also yield a reduction in the daylight availability, which results in the energy consumption for indoor artificial lighting being increased. This paper investigates, by means of dynamic simulations, the application of thermochromic windows to an existing office building in terms of energy savings on an annual basis, while also focusing on the effects in terms of daylighting and thermal comfort. In particular, due attention is paid to daylight availability, described through illuminance maps and by the calculation of the daylight factor, which in several countries is subject thresholds. The study considers both a commercially available thermochromic pane and a series of theoretical thermochromic glazing. The expected performance is compared to static clear and reflective insulating glass units. The simulations are repeated in different climatic conditions, showing that the overall energy savings compared to clear glazing can range from around 5% for cold climates to around 20% in warm climates, while not compromising daylight availability. Moreover the role played by the transition temperature of the pane is examined, pointing out an optimal transition temperatures that is irrespective of the climatic conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper investigates the extent to which office activity contributes to travel-related CO2 emission. Using ‘end-user’ figures[1], travel accounts for 32% of UK CO2 emission (Commission for Integrated Transport, 2007) and commuting and business travel accounts for a fifth of transport-related CO2 emissions, equating to 6.4% of total UK emissions (Building Research Establishment, 2000). Figures from the Department for Transport (2006) report that 70% of commuting trips were made by car, accounting for 73% of all commuting miles travelled. In assessing the environmental performance of an office building, the paper questions whether commuting and business travel-related CO2 emission is being properly assessed. For example, are office buildings in locations that are easily accessible by public transport being sufficiently rewarded? The de facto method for assessing the environmental performance of office buildings in the UK is the Building Research Establishment’s Environmental Assessment Method (BREEAM). Using data for Bristol, this paper examines firstly whether BREEAM places sufficient weight on travel-related CO2 emission in comparison with building operation-related CO2 emission, and secondly whether the methodology for assigning credits for travel-related CO2 emission efficiency is capable of discerning intra-urban differences in location such as city centre and out-of-town. The results show that, despite CO2 emission per worker from building operation and travel being comparable, there is a substantial difference in the credit-weighting allocated to each. Under the current version of BREEAM for offices, only a maximum of 4% of the available credits can be awarded for ensuring the office location is environmentally sustainable. The results also show that all locations within the established city centre of Bristol will receive maximum BREEAM credits. Given the parameters of the test there is little to distinguish one city centre location from another and out of town only one office location receives any credits. It would appear from these results that the assessment method is not able to discern subtle differences in the sustainability of office locations

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A carbon reduction strategy for a historic Grade 1 listed office building in London is presented. The study evaluates the impact of49 different carbon abatement options, quantified using building simulation software, auditing procedures and qualitative methods. The impact of each option is assessed against three criteria: carbon abatement potential, practicality and cost. The strategy comprises of18interventions,integrated within 12 key recommendations. Accumulative reduction of 37% (below a 2009 carbon emissions baseline)appears achievable and only feasible with heavy reliance on changes in occupant behaviour. This theme appears central in achieving realistic and significant carbon savings from listed buildings, where planning constraints relinquish potential for major building fabric alteration and renewable energy installations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The behaviour of building occupants can have a significant impact on in-use energy performance. In these pilot studies, based on the Elaboration Likelihood Model, interactivity was incorporated in the design of behavioural interventions to assess its effectiveness in promoting energy-saving behaviours. An interactive poster and an interactive prompt were designed to ‘nudge’ occupants’ behaviours towards energy-saving. The poster was installed in an office building and was intended to encourage occupants to save energy by taking the stairs, rather than the lifts, by providing them with cumulative metaphorical feedback. The prompt was installed in student halls of residence and intended to act as a reminder to the occupants to turn the lights off by providing them with an immediate playful reward. The results showed that interactivity can ‘nudge’ occupants’ behaviours when it is combined with a clear message/feedback. The results also suggest that simple immediate feedback can be effective in encouraging energy-efficient behaviours.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose – Corporate Occupiers require offices and services which meet their business needs, whilst landlords must attract and retain occupiers in order to maximise occupancy and rental income. The purpose of this research is to help landlords and corporate occupiers understand each other better, in order to achieve a mutually beneficial relationship. Design/methodology/approach - This paper analyses interviews with 1334 office tenants in the UK, conducted over an 11-year period, to investigate determinants of occupier satisfaction, loyalty and advocacy. Structural equation modelling and regressions are performed using respondents’ ratings of satisfaction with many aspects of occupancy as explanatory variables. The dependent variables include satisfaction with property management, value for money, overall occupier satisfaction, lease renewal intentions and occupiers’ willingness to recommend their landlord. Findings - The aspects with most impact on occupiers’ satisfaction are the office building itself, its location and amenities, and also communication with their property manager, a belief that their business needs are understood and the property manager’s responsiveness to occupiers’ requests. Occupiers’ loyalty depends mainly upon feeling that their rent and service charges provide value for money, an amicable leasing process, the professionalism of their property manager and the Corporate Social Responsibility of the Landlord. ‘Empathy’ is crucial to occupiers’ willingness to recommend their landlord, and clear documentation and efficient legal process improve occupiers’ perception of receiving ‘Value for Money’. Research Limitations - The sample is skewed towards occupiers of prime office buildings in the UK, owned by landlords who care sufficiently about their tenants to commission studies into occupier satisfaction. Practical implications - This research should help to improve the landlord – tenant relationship, benefitting the businesses that rent property and helping building managers understand where to focus their efforts to achieve maximum effect on occupier satisfaction, loyalty and advocacy. Originality/value - There has been little academic research into the determinants of satisfaction of occupiers of UK commercial property. This large-scale study enables the most influential factors to be identified and prioritised.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Building roofs play a very important role in the energy balance of buildings, especially in summer, when they are hit by a rather high solar irradiance. Depending on the type of finishing layer, roofs can absorb a great amount of heat and reach quite high temperatures on their outermost surface, which determines significant room overheating. However, the use of highly reflective cool materials can help to maintain low outer surface temperatures; this practice may improve indoor thermal comfort and reduce the cooling energy need during the hot season.This technology is currently well known and widely used in the USA, while receiving increasing attention in Europe. In order to investigate the effectiveness of cool roofs as a passive strategy for passive cooling in moderately hot climates, this paper presents the numerical results of a case study based on the dynamic thermal analysis of an existing office building in Catania (southern Italy, Mediterranean area). The results show how the application of a cool paint on the roof can enhance the thermal comfort of the occupants by reducing the operative temperatures of the rooms and to reduce the overall energy needs of the building for space heating and cooling.