25 resultados para Impulse response
Resumo:
Models of perceptual decision making often assume that sensory evidence is accumulated over time in favor of the various possible decisions, until the evidence in favor of one of them outweighs the evidence for the others. Saccadic eye movements are among the most frequent perceptual decisions that the human brain performs. We used stochastic visual stimuli to identify the temporal impulse response underlying saccadic eye movement decisions. Observers performed a contrast search task, with temporal variability in the visual signals. In experiment 1, we derived the temporal filter observers used to integrate the visual information. The integration window was restricted to the first similar to 100 ms after display onset. In experiment 2, we showed that observers cannot perform the task if there is no useful information to distinguish the target from the distractor within this time epoch. We conclude that (1) observers did not integrate sensory evidence up to a criterion level, (2) observers did not integrate visual information up to the start of the saccadic dead time, and (3) variability in saccade latency does not correspond to variability in the visual integration period. Instead, our results support a temporal filter model of saccadic decision making. The temporal impulse response identified by our methods corresponds well with estimates of integration times of V1 output neurons.
Resumo:
This article investigates the relation between stimulus-evoked neural activity and cerebral hemodynamics. Specifically, the hypothesis is tested that hemodynamic responses can be modeled as a linear convolution of experimentally obtained measures of neural activity with a suitable hemodynamic impulse response function. To obtain a range of neural and hemodynamic responses, rat whisker pad was stimulated using brief (less than or equal to2 seconds) electrical stimuli consisting of single pulses (0.3 millisecond, 1.2 mA) combined both at different frequencies and in a paired-pulse design. Hemodynamic responses were measured using concurrent optical imaging spectroscopy and laser Doppler flowmetry, whereas neural responses were assessed through current source density analysis of multielectrode recordings from a single barrel. General linear modeling was used to deconvolve the hemodynamic impulse response to a single "neural event" from the hemodynamic and neural responses to stimulation. The model provided an excellent fit to the empirical data. The implications of these results for modeling schemes and for physiologic systems coupling neural and hemodynamic activity are discussed.
Resumo:
In an ideal "reverberant" room, the energy of the impulse responses decays smoothly, at a constant rate of dB/s, so that gradually-decaying tails are added at the ends of sounds. Conversely, a single echo gives a flat energy-decay up to the echo's arrival time, which then drops abruptly, so that sounds with only echoes lack the decaying-tail feature of reverberation. The perceptual effects of these types of reflection pattern were measured with test-words from a continuum of steps between "sir" and "stir", which were each embedded in a carrier phrase. When the proportion of reflected sound in test-words is increased, to a level above the amount in the carrier, the test words sound more like "sir". However, when the proportion of reflected sound in the carrier is also increased, to match the amount in the test word, there can be a perceptual compensation where test words sound more like "stir" again. A reference condition used real-room reverberation from recordings at different source to receiver distances. In a synthetic-reverberation condition, the reflection pattern was from a "colorless" impulse response, comprising exponentially-decaying reflections that were spaced at intervals. In a synthetic-echo condition, the reflection pattern was obtained from the synthetic reverberation by removing the intervals between reflections before delaying the resulting cluster relative to the direct sound. Compensation occurred in the reference condition and in different types of synthetic reverberation, but not in synthetic-echo conditions. This result indicates that the presence of tails from reverberation informs the compensation mechanism.
Resumo:
In the United Kingdom and in fact throughout Europe, the chosen standard for digital terrestrial television is the European Telecommunications Standards Institute (ETSI) ETN 300 744 also known as Digital Video Broadcasting - Terrestrial (DVB-T). The modulation method under this standard was chosen to be Orthogonal Frequency Division Multiplex (0FD4 because of the apparent inherent capability for withstanding the effects of multipath. Within the DVB-T standard, the addition of pilot tones was included that can be used for many applications such as channel impulse response estimation or local oscillator phase and frequency offset estimation. This paper demonstrates a technique for an estimation of the relative path attenuation of a single multipath signal that can be used as a simple firmware update for a commercial set-top box. This technique can be used to help eliminate the effects of multipath(1).
Resumo:
Finding an estimate of the channel impulse response (CIR) by correlating a received known (training) sequence with the sent training sequence is commonplace. Where required, it is also common to truncate the longer correlation to a sub-set of correlation coefficients by finding the set of N sequential correlation coefficients with the maximum power. This paper presents a new approach to selecting the optimal set of N CIR coefficients from the correlation rather than relying on power. The algorithm reconstructs a set of predicted symbols using the training sequence and various sub-sets of the correlation to find the sub-set that results in the minimum mean squared error between the actual received symbols and the reconstructed symbols. The application of the algorithm is presented in the context of the TDMA based GSM/GPRS system to demonstrate an improvement in the system performance with the new algorithm and the results are presented in the paper. However, the application lends itself to any training sequence based communication system often found within wireless consumer electronic device(1).
Resumo:
The paper analyzes the performance of the unconstrained filtered-x LMS (FxLMS) algorithm for active noise control (ANC), where we remove the constraints on the controller that it must be causal and has finite impulse response. It is shown that the unconstrained FxLMS algorithm always converges to, if stable, the true optimum filter, even if the estimation of the secondary path is not perfect, and its final mean square error is independent of the secondary path. Moreover, we show that the sufficient and necessary stability condition for the feedforward unconstrained FxLMS is that the maximum phase error of the secondary path estimation must be within 90°, which is the only necessary condition for the feedback unconstrained FxLMS. The significance of the analysis on a practical system is also discussed. Finally we show how the obtained results can guide us to design a robust feedback ANC headset.
Resumo:
The analysis of office market dynamics has generally concentrated on the impact of underlying fundamental demand and supply variables. This paper takes a slightly different approach to many previous examinations of rental dynamics. Within a Vector-Error-Correction framework the empirical analysis concentrates upon the impact of economic and financial variables on rents in the City of London and West End of London office markets. The impulse response and variance decomposition reveal that while lagged rental values and key demand drivers play a highly important role in the dynamics of rents, financial variables are also influential. Stock market performance not only influences the City of London market but also the West End, whilst the default spread plays an important role in recent years. It is argued that both series incorporate expectations about future economic performance and that this is the basis of their influence upon rental values.
Resumo:
Interference by siren background-noise with speech transmitted from radio equipment (3) of an emergency-service vehicle, is reduced by apparatus (1) that subtracts (43) an estimate nk of the correlated siren-noise component from the contaminated signal yk supplied by the cab-microphone (2). The estimate nk is computed by FIR (finite impulse response) filtering of a siren-reference signal xk supplied by a unit (4) from one or more microphones located on or near the siren, or from the electric waveform driving the siren. The filter-coefficients wk are adjusted according to an LMS (least mean square) adaptive algorithm that is applied to the correlated-noise component ek of the fed-back noise-reduced signal, so as to bring about iterative cancellation with close frequency-tracking, of the siren noise.
Resumo:
Constrained principal component analysis (CPCA) with a finite impulse response (FIR) basis set was used to reveal functionally connected networks and their temporal progression over a multistage verbal working memory trial in which memory load was varied. Four components were extracted, and all showed statistically significant sensitivity to the memory load manipulation. Additionally, two of the four components sustained this peak activity, both for approximately 3 s (Components 1 and 4). The functional networks that showed sustained activity were characterized by increased activations in the dorsal anterior cingulate cortex, right dorsolateral prefrontal cortex, and left supramarginal gyrus, and decreased activations in the primary auditory cortex and "default network" regions. The functional networks that did not show sustained activity were instead dominated by increased activation in occipital cortex, dorsal anterior cingulate cortex, sensori-motor cortical regions, and superior parietal cortex. The response shapes suggest that although all four components appear to be invoked at encoding, the two sustained-peak components are likely to be additionally involved in the delay period. Our investigation provides a unique view of the contributions made by a network of brain regions over the course of a multiple-stage working memory trial.
Resumo:
We present a neoclassical model of capital accumulation with frictional labour markets. Under standard parameter values the equilibrium of the model is indeterminate and consequently displays expectations-driven business cycles – so-called endogenous business cycles. We study the properties of such cycles, and find that the model predicts the high autocorrelation in output growth and the hump-shaped impulse response of output found in US data – important features that existing endogenous real business cycle models fail to explain. The indeterminacy of the equilibrium stems from job search externalities and does not rely on increasing returns to scale as in most models.
Resumo:
A custom-built deconvolution technique for pulsed terahertz imaging is presented in this paper. It is examined as a tool for the measurement of thin transparent films. The power of the technique is illustrated by using the impulse response function, calculated in the deconvolution process, to recreate terahertz images of both sides of a piece of paper derived from one single terahertz reflection measurement.
Resumo:
Changes to the electroencephalogram (EEG) observed during general anesthesia are modeled with a physiological mean field theory of electrocortical activity. To this end a parametrization of the postsynaptic impulse response is introduced which takes into account pharmacological effects of anesthetic agents on neuronal ligand-gated ionic channels. Parameter sets for this improved theory are then identified which respect known anatomical constraints and predict mean firing rates and power spectra typically encountered in human subjects. Through parallelized simulations of the eight nonlinear, two-dimensional partial differential equations on a grid representing an entire human cortex, it is demonstrated that linear approximations are sufficient for the prediction of a range of quantitative EEG variables. More than 70 000 plausible parameter sets are finally selected and subjected to a simulated induction with the stereotypical inhaled general anesthetic isoflurane. Thereby 86 parameter sets are identified that exhibit a strong “biphasic” rise in total power, a feature often observed in experiments. A sensitivity study suggests that this “biphasic” behavior is distinguishable even at low agent concentrations. Finally, our results are briefly compared with previous work by other groups and an outlook on future fits to experimental data is provided.
Resumo:
Understanding neurovascular coupling is a prerequisite for the interpretation of results obtained from modern neuroimaging techniques. This study investigated the hemodynamic and neural responses in rat somatosensory cortex elicited by 16 seconds electrical whisker stimuli. Hemodynamics were measured by optical imaging spectroscopy and neural activity by multichannel electrophysiology. Previous studies have suggested that the whisker-evoked hemodynamic response contains two mechanisms, a transient ‘backwards’ dilation of the middle cerebral artery, followed by an increase in blood volume localized to the site of neural activity. To distinguish between the mechanisms responsible for these aspects of the response, we presented whisker stimuli during normocapnia (‘control’), and during a high level of hypercapnia. Hypercapnia was used to ‘predilate’ arteries and thus possibly ‘inhibit’ aspects of the response related to the ‘early’ mechanism. Indeed, hemodynamic data suggested that the transient stimulus-evoked response was absent under hypercapnia. However, evoked neural responses were also altered during hypercapnia and convolution of the neural responses from both the normocapnic and hypercapnic conditions with a canonical impulse response function, suggested that neurovascular coupling was similar in both conditions. Although data did not clearly dissociate early and late vascular responses, they suggest that the neurovascular coupling relationship is neurogenic in origin.
Resumo:
Using previously published data from the whisker barrel cortex of anesthetized rodents (Berwick et al 2008 J. Neurophysiol. 99 787–98) we investigated whether highly spatially localized stimulus-evoked cortical hemodynamics responses displayed a linear time-invariant (LTI) relationship with neural activity. Presentation of stimuli to individual whiskers of 2 s and 16 s durations produced hemodynamics and neural activity spatially localized to individual cortical columns. Two-dimensional optical imaging spectroscopy (2D-OIS) measured hemoglobin responses, while multi-laminar electrophysiology recorded neural activity. Hemoglobin responses to 2 s stimuli were deconvolved with underlying evoked neural activity to estimate impulse response functions which were then convolved with neural activity evoked by 16 s stimuli to generate predictions of hemodynamic responses. An LTI system more adequately described the temporal neuro-hemodynamics coupling relationship for these spatially localized sensory stimuli than in previous studies that activated the entire whisker cortex. An inability to predict the magnitude of an initial 'peak' in the total and oxy- hemoglobin responses was alleviated when excluding responses influenced by overlying arterial components. However, this did not improve estimation of the hemodynamic responses return to baseline post-stimulus cessation.
Resumo:
Neurovascular coupling in response to stimulation of the rat barrel cortex was investigated using concurrent multichannel electrophysiology and laser Doppler flowmetry. The data were used to build a linear dynamic model relating neural activity to blood flow. Local field potential time series were subject to current source density analysis, and the time series of a layer IV sink of the barrel cortex was used as the input to the model. The model output was the time series of the changes in regional cerebral blood flow (CBF). We show that this model can provide excellent fit of the CBF responses for stimulus durations of up to 16 s. The structure of the model consisted of two coupled components representing vascular dilation and constriction. The complex temporal characteristics of the CBF time series were reproduced by the relatively simple balance of these two components. We show that the impulse response obtained under the 16-s duration stimulation condition generalised to provide a good prediction to the data from the shorter duration stimulation conditions. Furthermore, by optimising three out of the total of nine model parameters, the variability in the data can be well accounted for over a wide range of stimulus conditions. By establishing linearity, classic system analysis methods can be used to generate and explore a range of equivalent model structures (e.g., feed-forward or feedback) to guide the experimental investigation of the control of vascular dilation and constriction following stimulation.