1 resultado para Suppliers

em Universitat de Girona, Spain


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thesis involves the development and implementation of a new and robust control system based on permeability trends but at the same time capable of reducing aeration proportionally to permeate flux. Permeability was made a key parameter for directly comparing temporary changes in membrane performance. Transmembrane pressure and flux were gathered every 10 seconds and permeability values were automatically calculated; different mathematical algorithms were applied for the signal filtering of on-line data. Short term and long term permeability trends were compared once a day, and a control action was applied proportionally to the short term/long term permeability ratio without exceeding the aeration flow recommended by the membrane suppliers.