7 resultados para Interferometria de cauda da onda

em Universitat de Girona, Spain


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial stiffness assessed by carotid-femoral pulse wave velocity (cfPWV) measurement is now well accepted as an independent predictor of vascular mortality and morbidity. However, the value of cfPWV has been considered to be limited for risk classification in patients with several vascular risk factors. Magnetic resonance (MR) allows measurement of PWV between two points, though to date mainly used to study the aorta. To assess the common carotid artery pulse wave velocity by magnetic resonance, determine their association with classical vascular risk factors and ischemic brain injury burden in patients with suspected ischemic cerebrovascular disease

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El present treball analitza la morfologia espermàtica de l'ejaculat de Sus domesticus, la histologia del conducte epididimari i la qualitat de l'esperma epididimari. El material d'estudi prové de mascles reproductors porcins de les races Landrace i Pietrain, sans i sexualment madurs. La metodologia emprada es basa en l'examen al microscopi òptic (camp dar, contrast de fases i contrast interferencial) i al microscopi electrònic (de rastreig i de transmissió). Per a l'anàlisi estadística de les dades s'ha utilitzat el test de la X2 de Pearson (p<0,01). L'estudi de la morfologia espermàtica de l'ejaculat permet distingir diversos tipus de gàmetes que s'han classificat en tres grups: espermatozoides madurs, espermatozoides immadurs i espermatozoides aberrants, així com algunes cèI.lules somàtiques. L'espermatozoide madur de Sus domesticus és un gàmeta típic de mamífer (format per tres parts: cap, peça de connexió i cua) en que destaquen: la forma oval i plana del cap, el desenvolupament d'una protuberància acrosòmica apical en una de les cares del cap i la presencia dels cossos laminars en la peça de connexió. L'espermatozoide immadur es caracteritza per la presencia de la gota citoplasmàtica, el major desenvolupament de la protuberància acrosòmica apical i per la flexibilitat del cap. Els espermatozoides aberrants es descriuen i classifiquen segons la morfologia externa i la morfologia interna, distingint-se una amplia gama de malformacions que afecten les diverses parts de l'espermatozoide. Les cèl·lules somàtiques presents en l'ejaculat ofereixen les característiques pròpies d'un macròfag i se les ha observat englobant espermatozoides immadurs. L'estudi de l'estructura i la ultraestructura de les tres regions anatòmiques de l'epidídim (caput, corpus i cauda) revela que: a) l'epiteli epididimari és pseudoestratificat amb esterocilis, b) cada regió epididimària presenta uns valors característics en relació al diàmetre intern del conducte, a l'alçada de l'epiteli, a la longitud dels esterocilis i al nombre de cèl·lules somàtiques luminals, i c) l'epiteli epididimari esta format per cinc tipus cel·lulars: les cèl·lules principals, les cèl·lules basals, les cèl·lules dares, les cèl·lules estretes i les cèl·lules basòfiles. Dels resultats obtinguts es pot deduir que: a) aquests cinc tipus cel·lulars es distribueixen al llarg del conducte epididimari de forma no homogènia, b) les cèl·lules basals, les cèl·lules principals, les cèI.Iules dares i les cèl·lules estretes són diversos estadis del desenvolupament d'un mateix tipus cel·lular especialitzat en la secreció i reabsorció cel·lular, i c) les cèl·lules basòfiles són les precursores de les cèl·lules somàtiques luminals. La qualitat de l'esperma procedent de les tres regions de l'epidídim ha estat analitzada a partir dels següents paràmetres espermàtics: vitalitat, resistència osmòtica dels acrosomes, estabilitat cefàlica, morfologia, malformacions i aglutinació. La vitalitat espermàtica disminueix progressivament al llarg del conducte epididimari. La resistència osmòtica dels acrosomes s'assoleix en la regió corporal de l'epidídim. L'estabilitat cefàlica dels espermatozoides és més elevada en les dues primeres regions de l'epidídim que en la regió caudal. Cada regió de l'epidídim es caracteritza per una morfologia espermàtica específica: a) el caput es caracteritza per l'elevat percentatge d'espermatozoides immadurs amb gota citoplasmàtica proximal, b) el corpus es caracteritza per l'elevat percentatge d'espermatozoides immadurs amb gota citoplasmàtica distal, i c) el cauda es caracteritza per l'elevat percentatge d'espermatozoides madurs. S'han estudiat les següents malformacions d'origen epididimari: espermatozoides de cua doblegada per l'anell de Jensen (origen en el cauda), espermatozoides de cua enrotllada i espermatozoides de cues fusionades (origen en el corpus). Els espermatozoides perden la capacitat de doblegar la cua per la peça intermèdia a mesura que avancen pel conducte epididimari. L'aglutinació espermàtica tendeix a augmentar progressivament al llarg del conducte epididimari, si bé, no s'han observat variacions significatives en els diversos tipus d'aglutinació. La maduració epididimaria dels espermatozoides de Sus domesticus és un procés lent i complex, i la qualitat de l'ejaculat depèn de que aquesta maduració hagi estat completa. La presencia en l'esperma ejaculat de formes gamètiques pròpies de l'esperma epididimari és un signe d'una incompleta maduració dels espermatozoides; i, pot considerar-se com un paràmetre indicador d'estrés del mascle reproductor, tant més quant més s'assembli a la morfologia espermàtica de la regió cefàlica de l'epidídim.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis proposes a framework for identifying the root-cause of a voltage disturbance, as well as, its source location (upstream/downstream) from the monitoring place. The framework works with three-phase voltage and current waveforms collected in radial distribution networks without distributed generation. Real-world and synthetic waveforms are used to test it. The framework involves features that are conceived based on electrical principles, and assuming some hypothesis on the analyzed phenomena. Features considered are based on waveforms and timestamp information. Multivariate analysis of variance and rule induction algorithms are applied to assess the amount of meaningful information explained by each feature, according to the root-cause of the disturbance and its source location. The obtained classification rates show that the proposed framework could be used for automatic diagnosis of voltage disturbances collected in radial distribution networks. Furthermore, the diagnostic results can be subsequently used for supporting power network operation, maintenance and planning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En les xarxes IP/MPLS sobre WDM on es transporta gran quantitat d'informacio, la capacitat de garantir que el trafic arriba al node de desti ha esdevingut un problema important, ja que la fallada d'un element de la xarxa pot resultar en una gran quantitat d'informacio perduda. Per garantir que el trafic afectat per una fallada arribi al node desti, s'han definit nous algoritmes d'encaminament que incorporen el coneixement de la proteccio en els dues capes: l'optica (WDM) i la basada en paquets (IP/MPLS). D'aquesta manera s'evita reservar recursos per protegir el trafic a les dues capes. Els nous algoritmes resulten en millor us dels recursos de la xarxa, ofereixen rapid temps de recuperacio, eviten la duplicacio de recursos i disminueixen el numero de conversions del trafic de senyal optica a electrica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La calidad de energía eléctrica incluye la calidad del suministro y la calidad de la atención al cliente. La calidad del suministro a su vez se considera que la conforman dos partes, la forma de onda y la continuidad. En esta tesis se aborda la continuidad del suministro a través de la localización de faltas. Este problema se encuentra relativamente resuelto en los sistemas de transmisión, donde por las características homogéneas de la línea, la medición en ambos terminales y la disponibilidad de diversos equipos, se puede localizar el sitio de falta con una precisión relativamente alta. En sistemas de distribución, sin embargo, la localización de faltas es un problema complejo y aún no resuelto. La complejidad es debida principalmente a la presencia de conductores no homogéneos, cargas intermedias, derivaciones laterales y desbalances en el sistema y la carga. Además, normalmente, en estos sistemas sólo se cuenta con medidas en la subestación, y un modelo simplificado del circuito. Los principales esfuerzos en la localización han estado orientados al desarrollo de métodos que utilicen el fundamental de la tensión y de la corriente en la subestación, para estimar la reactancia hasta la falta. Como la obtención de la reactancia permite cuantificar la distancia al sitio de falta a partir del uso del modelo, el Método se considera Basado en el Modelo (MBM). Sin embargo, algunas de sus desventajas están asociadas a la necesidad de un buen modelo del sistema y a la posibilidad de localizar varios sitios donde puede haber ocurrido la falta, esto es, se puede presentar múltiple estimación del sitio de falta. Como aporte, en esta tesis se presenta un análisis y prueba comparativa entre varios de los MBM frecuentemente referenciados. Adicionalmente se complementa la solución con métodos que utilizan otro tipo de información, como la obtenida de las bases históricas de faltas con registros de tensión y corriente medidos en la subestación (no se limita solamente al fundamental). Como herramienta de extracción de información de estos registros, se utilizan y prueban dos técnicas de clasificación (LAMDA y SVM). Éstas relacionan las características obtenidas de la señal, con la zona bajo falta y se denominan en este documento como Métodos de Clasificación Basados en el Conocimiento (MCBC). La información que usan los MCBC se obtiene de los registros de tensión y de corriente medidos en la subestación de distribución, antes, durante y después de la falta. Los registros se procesan para obtener los siguientes descriptores: a) la magnitud de la variación de tensión ( dV ), b) la variación de la magnitud de corriente ( dI ), c) la variación de la potencia ( dS ), d) la reactancia de falta ( Xf ), e) la frecuencia del transitorio ( f ), y f) el valor propio máximo de la matriz de correlación de corrientes (Sv), cada uno de los cuales ha sido seleccionado por facilitar la localización de la falta. A partir de estos descriptores, se proponen diferentes conjuntos de entrenamiento y validación de los MCBC, y mediante una metodología que muestra la posibilidad de hallar relaciones entre estos conjuntos y las zonas en las cuales se presenta la falta, se seleccionan los de mejor comportamiento. Los resultados de aplicación, demuestran que con la combinación de los MCBC con los MBM, se puede reducir el problema de la múltiple estimación del sitio de falta. El MCBC determina la zona de falta, mientras que el MBM encuentra la distancia desde el punto de medida hasta la falta, la integración en un esquema híbrido toma las mejores características de cada método. En este documento, lo que se conoce como híbrido es la combinación de los MBM y los MCBC, de una forma complementaria. Finalmente y para comprobar los aportes de esta tesis, se propone y prueba un esquema de integración híbrida para localización de faltas en dos sistemas de distribución diferentes. Tanto los métodos que usan los parámetros del sistema y se fundamentan en la estimación de la impedancia (MBM), como aquellos que usan como información los descriptores y se fundamentan en técnicas de clasificación (MCBC), muestran su validez para resolver el problema de localización de faltas. Ambas metodologías propuestas tienen ventajas y desventajas, pero según la teoría de integración de métodos presentada, se alcanza una alta complementariedad, que permite la formulación de híbridos que mejoran los resultados, reduciendo o evitando el problema de la múltiple estimación de la falta.