10 resultados para Fault-tolerant control
em Universitat de Girona, Spain
Resumo:
The speed of fault isolation is crucial for the design and reconfiguration of fault tolerant control (FTC). In this paper the fault isolation problem is stated as a constraint satisfaction problem (CSP) and solved using constraint propagation techniques. The proposed method is based on constraint satisfaction techniques and uncertainty space refining of interval parameters. In comparison with other approaches based on adaptive observers, the major advantage of the presented method is that the isolation speed is fast even taking into account uncertainty in parameters, measurements and model errors and without the monotonicity assumption. In order to illustrate the proposed approach, a case study of a nonlinear dynamic system is presented
Resumo:
L'objectiu general d'aquest treball és trobar i mostrar una eina que permeti obtenir una representació dels senyals procedents de sistemes dinàmics adequada a les necessitats dels sistemes de Supervisió Experta de processos. Aquest objectiu general es pot subdividir en diverses parts, que són tractades en els diferents capítols que composen el treball i que es poden resumir en els següents punts: En primer lloc, cal conèixer les necessitats dels sistemes de Supervisió: La gran quantitat de dades que provenen dels processos fa necessari el tractament d'aquestes dades per obtenir-ne d'altres, més elaborades, amb un nivell més elevat de representació. La utilització de raonament qualitatiu, pròpia dels éssers humans, comporta la necessitat de representar simbòlicament els senyals, de traduir les dades numèriques en símbols. La Supervisió de sistemes dinàmics comporta que el temps sigui una variable fonamental, la asincronia dels esdeveniments significatius per a la Supervisió fa que les representacions més adequades i útils dels senyals siguin asíncrones. Finalment,l'ús dels coneixements experimentals en la Supervisió dels processos comporta que les representacions més naturals siguin les més útils. Aquestes necessitats fan de la representació dels senyals mitjançant episodis l'eina amb més possibilitats per assolir els objectius que es volen assolir. Per això, es presenta un formalisme que permet descriure i incloure-hi la formalització i les diferents aproximacions a aquest tipus de representació ja existents i, al mateix temps, augmentar-ne la significació a través de característiques dels senyals que no es tenen en compte en les aproximacions ja existents. El següent pas és aprofitar el nou formalisme per obtenir una nova representació amb un grau més gran de significació, cosa que s'aconsegueix representant explícitament les discontinuïtats i els períodes estacionaris o d'estabilitat, molt significatius en Supervisió de processos. Un problema sempre present en el tractament de senyals és el soroll que els afecta. Per aquest motiu es presenta un mètode que permet filtrar el soroll de manera que les representacions resultants quedin afectades el mínim possible per aquest tractament. Finalment, es presenta l'aplicació en línia de les eines descrites. La representació en línia dels senyals comporta el tractament de la incertesa inherent al coneixement parcial del senyal (un episodi no pot ser determinat i caracteritzat completament fins que no s'acaba). L'obtenció de resultats amb determinats graus de certesa és perfectament coherent amb la seva utilització posterior mitjançant Sistemes Experts o altres eines de la IA. Totes les aportacions del treball vénen acompanyades d'exemples i/o aplicacions que permeten observar-ne la utilitat i les limitacions.
Resumo:
One of the techniques used to detect faults in dynamic systems is analytical redundancy. An important difficulty in applying this technique to real systems is dealing with the uncertainties associated with the system itself and with the measurements. In this paper, this uncertainty is taken into account by the use of intervals for the parameters of the model and for the measurements. The method that is proposed in this paper checks the consistency between the system's behavior, obtained from the measurements, and the model's behavior; if they are inconsistent, then there is a fault. The problem of detecting faults is stated as a quantified real constraint satisfaction problem, which can be solved using the modal interval analysis (MIA). MIA is used because it provides powerful tools to extend the calculations over real functions to intervals. To improve the results of the detection of the faults, the simultaneous use of several sliding time windows is proposed. The result of implementing this method is semiqualitative tracking (SQualTrack), a fault-detection tool that is robust in the sense that it does not generate false alarms, i.e., if there are false alarms, they indicate either that the interval model does not represent the system adequately or that the interval measurements do not represent the true values of the variables adequately. SQualTrack is currently being used to detect faults in real processes. Some of these applications using real data have been developed within the European project advanced decision support system for chemical/petrochemical manufacturing processes and are also described in this paper
Resumo:
This paper deals with fault detection and isolation problems for nonlinear dynamic systems. Both problems are stated as constraint satisfaction problems (CSP) and solved using consistency techniques. The main contribution is the isolation method based on consistency techniques and uncertainty space refining of interval parameters. The major advantage of this method is that the isolation speed is fast even taking into account uncertainty in parameters, measurements, and model errors. Interval calculations bring independence from the assumption of monotony considered by several approaches for fault isolation which are based on observers. An application to a well known alcoholic fermentation process model is presented
Resumo:
Fault location has been studied deeply for transmission lines due to its importance in power systems. Nowadays the problem of fault location on distribution systems is receiving special attention mainly because of the power quality regulations. In this context, this paper presents an application software developed in Matlabtrade that automatically calculates the location of a fault in a distribution power system, starting from voltages and currents measured at the line terminal and the model of the distribution power system data. The application is based on a N-ary tree structure, which is suitable to be used in this application due to the highly branched and the non- homogeneity nature of the distribution systems, and has been developed for single-phase, two-phase, two-phase-to-ground, and three-phase faults. The implemented application is tested by using fault data in a real electrical distribution power system
Resumo:
Not considered in the analytical model of the plant, uncertainties always dramatically decrease the performance of the fault detection task in the practice. To cope better with this prevalent problem, in this paper we develop a methodology using Modal Interval Analysis which takes into account those uncertainties in the plant model. A fault detection method is developed based on this model which is quite robust to uncertainty and results in no false alarm. As soon as a fault is detected, an ANFIS model is trained in online to capture the major behavior of the occurred fault which can be used for fault accommodation. The simulation results understandably demonstrate the capability of the proposed method for accomplishing both tasks appropriately
Resumo:
ABSRACT This thesis focuses on the monitoring, fault detection and diagnosis of Wastewater Treatment Plants (WWTP), which are important fields of research for a wide range of engineering disciplines. The main objective is to evaluate and apply a novel artificial intelligent methodology based on situation assessment for monitoring and diagnosis of Sequencing Batch Reactor (SBR) operation. To this end, Multivariate Statistical Process Control (MSPC) in combination with Case-Based Reasoning (CBR) methodology was developed, which was evaluated on three different SBR (pilot and lab-scales) plants and validated on BSM1 plant layout.
Resumo:
Les noves tecnologies a la xarxa ens permeten transportar, cada cop més, grans volums d' informació i trànsit de xarxa amb diferents nivells de prioritat. En aquest escenari, on s'ofereix una millor qualitat de servei, les conseqüències d'una fallada en un enllaç o en un node esdevenen més importants. Multiprotocol Lavel Switching (MPLS), juntament amb l'extensió a MPLS generalitzat (GMPLS), proporcionen mecanismes ràpids de recuperació de fallada establint camins, Label Switch Path (LSPs), redundants per ser utilitzats com a camins alternatius. En cas de fallada podrem utilitzar aquests camins per redireccionar el trànsit. El principal objectiu d'aquesta tesi ha estat millorar alguns dels actuals mecanismes de recuperació de fallades MPLS/GMPLS, amb l'objectiu de suportar els requeriments de protecció dels serveis proporcionats per la nova Internet. Per tal de fer aquesta avaluació s'han tingut en compte alguns paràmetres de qualitat de protecció com els temps de recuperació de fallada, les pèrdues de paquets o el consum de recursos. En aquesta tesi presentem una completa revisió i comparació dels principals mètodes de recuperació de fallada basats en MPLS. Aquest anàlisi inclou els mètodes de protecció del camí (backups globals, backups inversos i protecció 1+1), els mètodes de protecció locals i els mètodes de protecció de segments. També s'ha tingut en compte l'extensió d'aquests mecanismes a les xarxes òptiques mitjançant el pla de control proporcionat per GMPLS. En una primera fase d'aquest treball, cada mètode de recuperació de fallades és analitzat sense tenir en compte restriccions de recursos o de topologia. Aquest anàlisi ens dóna una primera classificació dels millors mecanismes de protecció en termes de pèrdues de paquets i temps de recuperació. Aquest primer anàlisi no és aplicable a xarxes reals. Per tal de tenir en compte aquest nou escenari, en una segona fase, s'analitzen els algorismes d'encaminament on sí tindrem en compte aquestes limitacions i restriccions de la xarxa. Es presenten alguns dels principals algorismes d'encaminament amb qualitat de servei i alguna de les principals propostes d'encaminament per xarxes MPLS. La majoria dels actual algorismes d'encaminament no tenen en compte l'establiment de rutes alternatives o utilitzen els mateixos objectius per seleccionar els camins de treball i els de protecció. Per millorar el nivell de protecció introduïm i formalitzem dos nous conceptes: la Probabilitat de fallada de la xarxa i l'Impacte de fallada. Un anàlisi de la xarxa a nivell físic proporciona un primer element per avaluar el nivell de protecció en termes de fiabilitat i disponibilitat de la xarxa. Formalitzem l'impacte d'una fallada, quant a la degradació de la qualitat de servei (en termes de retard i pèrdues de paquets). Expliquem la nostra proposta per reduir la probabilitat de fallada i l'impacte de fallada. Per últim fem una nova definició i classificació dels serveis de xarxa segons els valors requerits de probabilitat de fallada i impacte. Un dels aspectes que destaquem dels resultats d'aquesta tesi és que els mecanismes de protecció global del camí maximitzen la fiabilitat de la xarxa, mentre que les tècniques de protecció local o de segments de xarxa minimitzen l'impacte de fallada. Per tant podem assolir mínim impacte i màxima fiabilitat aplicant protecció local a tota la xarxa, però no és una proposta escalable en termes de consum de recursos. Nosaltres proposem un mecanisme intermig, aplicant protecció de segments combinat amb el nostre model d'avaluació de la probabilitat de fallada. Resumint, aquesta tesi presenta diversos mecanismes per l'anàlisi del nivell de protecció de la xarxa. Els resultats dels models i mecanismes proposats milloren la fiabilitat i minimitzen l'impacte d'una fallada en la xarxa.
Resumo:
Les restriccions reals quantificades (QRC) formen un formalisme matemàtic utilitzat per modelar un gran nombre de problemes físics dins els quals intervenen sistemes d'equacions no-lineals sobre variables reals, algunes de les quals podent ésser quantificades. Els QRCs apareixen en nombrosos contextos, com l'Enginyeria de Control o la Biologia. La resolució de QRCs és un domini de recerca molt actiu dins el qual es proposen dos enfocaments diferents: l'eliminació simbòlica de quantificadors i els mètodes aproximatius. Tot i això, la resolució de problemes de grans dimensions i del cas general, resten encara problemes oberts. Aquesta tesi proposa una nova metodologia aproximativa basada en l'Anàlisi Intervalar Modal, una teoria matemàtica que permet resoldre problemes en els quals intervenen quantificadors lògics sobre variables reals. Finalment, dues aplicacions a l'Enginyeria de Control són presentades. La primera fa referència al problema de detecció de fallades i la segona consisteix en un controlador per a un vaixell a vela.
Resumo:
El desalineamiento temporal es la incorrespondencia de dos señales debido a una distorsión en el eje temporal. La Detección y Diagnóstico de Fallas (Fault Detection and Diagnosis-FDD) permite la detección, el diagnóstico y la corrección de fallos en un proceso. La metodología usada en FDD está dividida en dos categorías: técnicas basadas en modelos y no basadas en modelos. Esta tesis doctoral trata sobre el estudio del efecto del desalineamiento temporal en FDD. Nuestra atención se enfoca en el análisis y el diseño de sistemas FDD en caso de problemas de comunicación de datos, como retardos y pérdidas. Se proponen dos técnicas para reducir estos problemas: una basada en programación dinámica y la otra en optimización. Los métodos propuestos han sido validados sobre diferentes sistemas dinámicos: control de posición de un motor de corriente continua, una planta de laboratorio y un problema de sistemas eléctricos conocido como hueco de tensión.