6 resultados para Electric lines
em Universitat de Girona, Spain
Resumo:
This paper focus on the problem of locating single-phase faults in mixed distribution electric systems, with overhead lines and underground cables, using voltage and current measurements at the sending-end and sequence model of the network. Since calculating series impedance for underground cables is not as simple as in the case of overhead lines, the paper proposes a methodology to obtain an estimation of zero-sequence impedance of underground cables starting from previous single-faults occurred in the system, in which an electric arc occurred at the fault location. For this reason, the signal is previously pretreated to eliminate its peaks voltage and the analysis can be done working with a signal as close as a sinus wave as possible
Resumo:
Fault location has been studied deeply for transmission lines due to its importance in power systems. Nowadays the problem of fault location on distribution systems is receiving special attention mainly because of the power quality regulations. In this context, this paper presents an application software developed in Matlabtrade that automatically calculates the location of a fault in a distribution power system, starting from voltages and currents measured at the line terminal and the model of the distribution power system data. The application is based on a N-ary tree structure, which is suitable to be used in this application due to the highly branched and the non- homogeneity nature of the distribution systems, and has been developed for single-phase, two-phase, two-phase-to-ground, and three-phase faults. The implemented application is tested by using fault data in a real electrical distribution power system
Resumo:
In this paper we address the problem of extracting representative point samples from polygonal models. The goal of such a sampling algorithm is to find points that are evenly distributed. We propose star-discrepancy as a measure for sampling quality and propose new sampling methods based on global line distributions. We investigate several line generation algorithms including an efficient hardware-based sampling method. Our method contributes to the area of point-based graphics by extracting points that are more evenly distributed than by sampling with current algorithms
Resumo:
Two common methods of accounting for electric-field-induced perturbations to molecular vibration are analyzed and compared. The first method is based on a perturbation-theoretic treatment and the second on a finite-field treatment. The relationship between the two, which is not immediately apparent, is made by developing an algebraic formalism for the latter. Some of the higher-order terms in this development are documented here for the first time. As well as considering vibrational dipole polarizabilities and hyperpolarizabilities, we also make mention of the vibrational Stark effec
Resumo:
Quantum molecular similarity (QMS) techniques are used to assess the response of the electron density of various small molecules to application of a static, uniform electric field. Likewise, QMS is used to analyze the changes in electron density generated by the process of floating a basis set. The results obtained show an interrelation between the floating process, the optimum geometry, and the presence of an external field. Cases involving the Le Chatelier principle are discussed, and an insight on the changes of bond critical point properties, self-similarity values and density differences is performed
Resumo:
En aquesta tesi s'han estudiat les propietats antitumorals d'una variant de la ribonucleasa pancreàtica humana anomenada PE5 que incorpora un senyal de localització nuclear. Aquest estudi mostra que PE5 indueix l'apoptosi de les cèl·lules tractades i que aquesta mort és independent de l'activitat de p53. A més, l'efecte citotòxic no es veu afectat per un fenotip de resistència a múltiples drogues. Les dades també mostren que l'activitat citotòxica de PE5 és selectiva per a cèl·lules tumorals in vitro i que la capacitat citotòxica de les dues ribonucleases és semblant. S'ha estudiat l'efecte d'aquestes dues ribonucleases sobre el cicle cel·lular, l'activació de diferents caspases i l'expressió de proteïnes relacionades amb l'apoptosi i el cicle cel·lular. Els resultats indiquen que PE5 i l'onconasa maten les cèl·lules a través de mecanismes diferents. A més, PE5 però no l'onconasa, redueix l'acumulació de glicoproteïna-P en dues línies cel·lulars resistents a múltiples drogues.